ML20040A794

From kanterella
Jump to navigation Jump to search
Public Version of Revision 2 to Emergency Plan Implementing Procedure 550-3, Radiological Supplies for Medical Emergencies. Revised Table of Contents Encl
ML20040A794
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 12/15/1981
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20040A786 List:
References
EPIP-550-3, NUDOCS 8201220127
Download: ML20040A794 (8)


Text

"

~

I RADIOLOGICAL SUPPLIES FOR !EDICAL E!ERGENCIES 4

EPIP 550-3 TAB.E OF CCNTENTS PAGE DATE PEVISION SECTION TITLE Table of Centents 1

DEC 15 1981 2

2 DEC 15 1981 2

A Purpose

.c 8

References C

Prerequisites D

Precautions E

Limitations & Actions DEC 15 1981 1

3 F

Procedure G

Checklist H

Tecnnical Specification References 4

DEC 15 1981 1

Attachment A 5

OEC 15 1981 0

I 6

DEC 15 1981 0

Attachment B 7

CEC 15 1981 0

8 DEC 15 1981 0

4

(

l I

O I

~ - -,

1 1

This procedure contains 8 pages.

APPROVED [I M f

i

~

s 7

8201220127 820104 PDR ADOCK 05000295 F

pop

EPIP 550-3 Rev. 2 DEC 15 1981 RADIOLOGICAL SUPPLIES FOR IEDICAL EERGE?CIES

_~

A.

RJRR3SE The purpose of this procedure is to cutline the supplies to be maintained in the Victory Hospital Radiological Emergency Supply Locker, and the Zion A Station, RMC decontaminaticn and sampling kits.

8.

REFEPENCES 1)

Generating Station Emergency Plan (GSEP) 2)

RMC - Victory Hospital Manual 3)

EPIP 550-1 "On-Site Non-Radiological Emergency Response Equipment"

" Environmental Emergency Radiological Equipment" 4)

EPIP 550-2 5)

EPIP 550 4 "On-Site Raciological Emergency Respcnse Equipment" 6)

EPIP 550-5 "TSC and OSC Radiological Supplies" C.

PREREOUISITES None D.

PRECAUTIONS None E.

LIMITATIONS & ACTIONS This procedure covers only the supplies retained by Victory Hospital 1) and included in the RMC decontamination and sampling kits located in the Zicn 617' decen recm.

2)

The Rad Chem Supervisor or his designee will be respcnsible for documentation and centrol of these supplies.

r 2

0049E C007A

~~ ~

~~-

EPIP 550 3 Rev. 1 DEC 15 1981

~

F.

EPCWDURE 1)

An inventcry of the emergency supplies at Victory Memorial Hospital's Rad Emergency locker will be performed quarterly. This inventory should be done using Attachment A.

Note any missing items and quantity on the form and return the form to the Rad / Chem Foreman.

Film badges and finger rings should be replaced quarterly.

2)

Replace the GM counter and ion chamber with newly calibrated instruments each quarter. Check other instruments (probes, self readers) for physical damage. Self readers are to be replaced every other quarter.

3)

The Rad / Chem Foreman will assure the missing items will be replaced as scon as possible.

4)

Radiation Management Corp (RMC) will perform an annual inspection at Victory Memorial Hospital. A letter from RMC to Zica Station documenting this inspection will be kept on file in the Rad / Chem Department.

5)

Two decontamination kits and two sampling kits in the 617' level of the aux bldg are provided by RMC. Once per month the tape or security ceal en one of each of these kits will be verified to be intact. If the seal has been broken, an inventory will ce performed using Attachment B.

Note any missing items that cannot be replaced from the duplicate kit, and the quantities on the form anc return the form to the Rad /Cnem Foreman.

6)

The Rad / Chem Foreman will assure the missing items will be replaced

~

as scan as possible.

7)

Once per year, RMC will inventory the centents of the decon and sampling kits. A letter from RMC to Zion Station dccumenting this inspection will be kept on file in the Rad / Chem Cepartment.

G.

CHECXLIST Attachment A "Victcry Hospital Radiation Emergency Supplies" Attactment 8 "RMC Decen ano Sampling Kit Inventory" H.

TECFNICAL SPECIFICATION REFEFEFCES

_ Ncne 0049E 3

CC07A

N EPIP 550-3 Rev. 1 DEC 15 1981 ATTACHENT A VICTORY MEMORIAL HOSPITAL RADIATION EERGENCY LOCKER SUPPLIES CESCRIPTICN Quantity Quantity COMENTS Recuired Present 1

GM Counter with pancake probe 1

Aloha Detector 1

Icn Chamcer 1

Dosimeter Charcer 4

0-500 MR Cosimeters 6

0-2C0 MR Dosimeters 10 D-cell Batteries A

AA Batteries 6.75-volt Mercury Batteries 2

l 100 ft Radiaticn Rooe 6

Sicns - Hich Radiation Signs - Radiation Area -

Authorized Entry Only 5

Signs - Airborne Radioactivity 6

Sicns - Radioactive Materials 3

Signs - Radiacion Area -

Radioactive Materials Authorized Entry Only 6 ea A

00 NOT ENTER signs Wrapping paper 36" wide (fire retardent) (roll) 1 Stec-off Pads - check shoes 6

Step-off Pads - remove protective clothing 6

Step-off Pads - remove protective footwear 6

Coveralls - size 46 6

Coveralls - size 36 6

6 Coveralls - size 42 Shce Covers (cairs) 6 i

Full-Face Particulate Filter 3

l Resoirators A

0049E,

0007A

EPIP 550-3 R:iv. O ATTACHENT A (continued)

DESCRIPTION QJantity Quantity 03MENTS Required Present Half-Face Particulate Filter 6

Respirators Type H Filter Cartridge - 2 per cackage 1 okg 2" Masking Tape (rolls) 6 Film badges (less than 4 months old) 12 Ring TLD's (less than 4 montns old) 6

)

Plastic Bacs - all sizes Assorted Shower Hooks (dozen) 2 Gummed Labels

" Rad Material" Various ITEMS MAINTAINED IN REA ROOM Decontamination Kit 1

Patient Samole Taking Kit 2

Decon Table 1

Mobile 1

Lead Container, high activity soecimens 1

Herculite floor coverinos (set) 1 30 gallon clastic decon centainer 1

1 l

RCT Initials Date l

l CCA9E 5

0007A

EPIP 550-3

~

Rev. O DEC 15 1981 ATTACHfENT 8 RMC DECCN AND SAMPLING KIT INENTDRY Decon kit seal intact:

YES NO Sampling kit seal intact: YES NO If seals are intact on both, no inventory required. If seal is broken, perform inventory using the following.

DESCRIPTION Quantity Quantity COMtENTS Recuired Present DECON KIT - SECTION 1 1

Forceps 1

Notebock Radiation status cards Various Anatomical drawings various 1 Jar Nivea cream Saline solutico 1 Octtle Gloves Various 1 Packet Aperture Orape Plastic beakers 2

Various Plastic bags Collodion skin orotectant 1 Battle DECN KIT - SECTION 2 2 Boxes Cotton balls Gauze pads various Various Decen sponges 1 Battle Bleach 1 Battle Hycrogen peroxide Betadine 1 Battle I

6 OC49E I

CC07A

a EPIP 550-3 R2v. 0 CEC 151991

?

ATTACHWJ4T B (Centinued)

DESCRIPTION Quantity Quantity CCMbENTS Recuired Present DECON KIT - SECTION 3 1

Wash bottle 1

Syringe rubber ball 1

Nail clippers 1 Battle Turco soap 1 Box Tissues Cotton applicators 1 Bag 1

Syringe 1

Shave kit Solution bowl 1

1 Scrub brush SAMPLING KIT.

Nasal swabs 4 Tubes Aural swabs 4 Tubes A Tubes Oral swabs Skin fold swabs A Tubes Irrigation fluid 2 Battles Wound exudate bottles 4

Tissue sample bottles A

Hair sample bottles 4

Nail sample bottles 4

Blood vacutainers 4

2 Eyedropper bottles vomitus containers & lids 2

Feces containers & lids 2

24 Hour urine container & lid 1

l' Marker 1

Tweezers 7

C049E 0007A

a-

.x,

EPIP 550-3 Rev. O DEC 151981 ATTACHM54TB (Continued)

DESCRIPTION Quantity Quantity CCMfENTS Recuired Present SAMPLING KIT 1

Nail clippers Various Plastic bags Various Nucon smears Needles 2

Needle holder 1

Various Latels Enveloces Various RCT Initials Date 1

FINAL 8

C049E CC07A

_ _ _ _