ML20039E829

From kanterella
Jump to navigation Jump to search
Class IE 460V Motor Control Center Schedule Unit 2 & Common. Sheet 13
ML20039E829
Person / Time
Site: Midland
Issue date: 07/10/1981
From:
BECHTEL GROUP, INC.
To:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML20038B946 List: ... further results
References
CON-7220 E-18(Q), NUDOCS 8201110503
Download: ML20039E829 (1)


Text

--

s s

1 Remord IlllIlIHH Safety Products 45 Great Valley Parkway Malvern. PA l9355 2I5/647-7200 January 15, 1982 Ms. Ignnette Hendricks Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555 Reference Proposed Rules:

Federal Register Vol. h6, No. 212 Monday, November 8, 1981 10CFR Part 20 Replacement of Provisions Regulatory Guide 8.15 Incorporated by Reference in 20.103

Dear Lynnette,

Thank you for the consideration to coment after the deadline of January h.

We requested an extension to that date in writing prior to that time, and were verbally denied the request citing a deadline the Federal Register had given NRC. Consideration was given to allow our late submission of. comments if they could arrive during the middle of January. We hope these comments are properly presented in our limited preparation time.

Rexnord Electronic Products Division wishes to coment on four (h) areas:

1.

General: the permissable concentration of radioactive substances is much lower than the TLV (Life Hazard) of gases / vapors, therefore the closed circuit positive pressure breathing apparatus (RP) should have language stating this apparatus is acceptable in IDLH - immediately dangerous to life and health - conditions. Probable reference should'be in footnote k of appendix A.

2.

F.R. Page 55272, Section 5, states that a company (licensee) could gain higher protection factors should they wish by applying to the commission and demonstrating them. We interpret this section to expand IN-81-26 notice that a company (licensee) has a good opportunity to have a higher I

protection factor (PF) assigned concerning an "RP" for whatever reason should they wish to apply to the commission. We further 1.nterpret that:

l 1.

Passage of fit test requirements in IN-81-26 which demonstrate this higher protection factor will be the basis for approval of the application and 2.

the application process is not such a complicated time consuming process as to substantially reduce the desirability of the application for higher protection factor.

8202080503 820105 PDR PR 20 46FM5271 PDR snstruments self-conta:ned breathmg apparatus

L~

1.,

Ms. Ignnette Hendricks Page 2 January 15, 1982 3.

F.R. Page 55272. We request that you change the description in appendix A for RP to " Positive Pressure - recirculating (closed circuit)" device rather than " pressure demand device". Designation RD should be NPR -

Non Positive Pressure - recirculating. The positive pressure BioPaks operate on a constant flow to a breathing chamber rather than a demand from a regulator. A " demand" designation vould be technically incorrect.

The Positive Pressure wording for all breathing apparatus is more techni-cally correct as to what the device does rather than how it works. This language is consistent with industry wording, the OSHA 1910 Sub. Part. L.

fire brigade wording and other recognized authorities working with respirators. We would suggest that other SCBA should use the Positive Pressure and Negative Pressure designations also. The D might be: D=

Demand (negative pressure in part of the respiration cycle) and PD should be: PD = Positive Pressure (i.e.: pressure demand).

h.

F.R. Page 55273 Footnote 1 should be changed to read " Quantitative fit testing must be performed on each individual to achieve a minimum protection factor of 5,000 (0.02% leakage). Perceptible outvard leakage of gas from this or any self contained breathing apparatus is unacceptable because service life vill be reduced substantially. Special training in the use of this type of apparatus must be provided to the wearer.

(See footnote k.) We request that footnote k be noted with footnote 1 for "JP" units.

This language noted in the four areas is more consistent with the intent and substance of the IN-81-26.

In item h, the wording presently written confuses duration with protection factors. The suggested wording is more appropriate.

We hora that you will favorably receive these suggestions and incorporate them in the final rule. If you differ with these comments or you have any questions, please let me know immediately.

Sincerely, REXNORD ELECTRONIC PRODUCTS DIVISION 9

z

[a J.'9el Gramling J

N 6nal Accounts Manage JJG/ led

e a

5 h

O N

CElv o g

e e

jag NOTE T0:

Document Control 9.

g 2 199g g:

Room 016 9h

/cny, FROM:

Please place the attached document in the PDR using the following file and file points:

PDR File Related Documents (SelectOne)

(Enter if appropriate)

A/2 2 0 Proposed Rule (PR),[ Y6 f # ff.1 +/ ACRS Minutes No.

Reg. Guide

~

Proposed Rule (PR)

Draft Reg. Guide Draft Reg. Guide Petition (PRM)

Reg. Guide R/f' Effective Rule (RM)

_ Effective Rule (RM)

Petition (PRM)

Federal Register Notice SD Task No.

NUREG Report-

-e Contract No.

Subject:

O Exn

,[2 d

t.C-d./f + w,~

30. t 0 3 O