I-s
~a 1.1
?
t V
U rs s
g yryyn W f j'4k i
certifi?1 MV' ICentral File SD ALPliA/RD JAN 2 81981 OliSB SUBJ/RD Central File SD ALPliA/RD RSmith KGoller
'f1Ef40RNIDU:1 FOR: Thcmas F. Engelhardt, ELD and Federal '
Guiber Register Liaisen Officer RAlexander C~plin a
FR&4:
Karl R. Goller, Director Division.of Siting, llcalth and Safeguards Standards
SUBJECT:
INCORPORATION BY
REFERENCE:
REGULATORY GUIDE 8.15
,J-Pursuant to your mcmorandum of January 8,1981, to Office Directors, we have prepared the cover page called for in the letter of December 31,1980, to you frota the Director of Federal Register and are arranging for it to be printed and attached to the front of Regulatory Guide 3.15.
i
~~
t!e are enclosing a copy of Regulatory Guide 8.15 with the cover page attached for you to forward to the Office of the Federal Register. The cover page lan-guage has been coordinated with Thomas F. Dorian of your staff.
Original signed by IGirlIt Goller Karl R. Goller, Director Division of Siting, llealth and Safeguards Standards
Enclosure:
As stated Task No.: N/A 8112300269 810128 PDR REGGD
[1-2a-81 mncrp S.0.:0115.B Q,..
. S.D :PSB
.f.SD:Gl!,SB M /.,g y 6..'SD.:RilS'S
,.., /..
S,D : S..l.i.S S,, K.2,6,,,
//
murp J.L.C a..p l. i. n.......E. l.l.i.l. l..g.........
R..EA.. l e x..a.n..e.r... J C.G u i.e r t.....
.K.R.,G. o.l..l. e.r..,,,,
.../..:.3 /. 81..
loue>
..../.). )./.81 1/g/81 1/,g/81 1/JF/81 1
1 ame rosm aio no noirmcw oua OFFICIAL RECORD COPY amo we-3:*. -
x D33IC1!.cD ORIGliil's
. Corrified Dy I
UNITED STATES NUCLEAR REGULATORY COMMISSION NOTICE TO RECIPIENTS REGULATORY GUIDE 8.15-
' l*
The Director of the Federal Registe r has identified a need to clarify the regula-tory status of Regulatory Guide 8.15, " Acceptable Programs for Respiratory Pro-I tection."
Regulatory Guide 8.15, by virtue of its incorporation by reference into paragraph 20.103(c) of 10 CFR Part 20, " Standards for Protection Against Radiation," has the same status as a regulation for those licensees who, in th.e determination of the radioactive material intake for occupationally exposed individuals, choose to make allowance for the protection afforded by respiratory protection devices.
Therefore, for these licensees this notice sunersedes, for the attached Regula-i tory Guide 8.15, the language at the bottom of the first page which states that regu-latory guides are not substitutes for regulations and compliance with them is not required.
l l
l
.......m.
- my General National Archwes
\\
Services and b
L1
. Administration Records Service Washington. DC 20408 t
November 25, 1980 Thomas F. Engelhardt p}Q Deputy Executive Legal Director ggt %G -
_ Nuclear Regulatory Commission ud Washington, DC 20555 1U' t> ear Mr. Engelhardt:
We have completed the review of your preliminary list of materials you wish to have reapproved for incorporation by reference.
The following materials are presently on file at the Office of the Federal Register:
ASME Boiler and Pressure Vessle Code,Section III, Division 1, Articles NCA and NB, 1977 edition with S77, W77, and S78 addenda ASA B31.1, 1955 edition USAS B31.1.0, 1967 edition with 1971 addendum USAS B31.7, 1969 edition with 1971 addendum ASTM E-185-73 and E-185-79 IAEA'INFRCIRC/225/Rev.1 All other materials you wish incorporated must be filed with the Office of the Federal Fegister along with your formal request.
The first three items on your preliminary list cannot be approved for incorporation by reference. The first two are personnel manuals. We generally will not approve personnel manuals because there is no need to incorporate them by reference.
Persons affected by the incorporating regualtion are already bound to comply with the manuals without giving them the status of regulations by incorporating them by reference.
~
- 1>-
The third item is a Regulatory Guide. This sould not be incorporated by reference because on the first page of the Guide it says that USNRC Fegulatory Guides "are not substitutes for regulations and compliance with them is not required." It does not seem right to have a document which on it,s face purports to be nonregu/o, tory but which is elevated to -
regulatory status by incorporating it by reference in a regulation.
I I have informed John Philips of your staff of the above determinations.
j If you have any further question, please call me at 523-4534.
Thank you very much for your cooperation in this v.atter.
Sincerely,
_ f
,,. ! ~ -
Cary Segal gg3,d N p Attorney, Office of the Federal Register hf ATTACHMENT B
DESIG'r0 ORIGINM; Certtue:. y J
10 CFR Chapter I - fiUCLEAR REGULATORY C0:'.'ilSS10N Title CFR Citation 7 5-fiRC l'anual Chapter 4139 3
c(2) 0.735-28.
Federal Personnel 14anual - Chapter 304 20.103(c)
Reg. Guide 8.15 " Acceptable Programs for.
Respirntory Protection" j
35.21(c)
Scientific Comittee on Radiation Dasimetry of the American Assoc. of Physicists in I'.?dicine (Physics in 14edicine and Biology, Vol.16, fio. 3,1971, 379-396).
ASME Boiler and Pressure Code 50.55a(b)(1)
Section 111, Division 1, Articles fica * + fib Edition 1963 Addenda S 64 W 64 Edition 1965 Addenda S 65 W 65 S 66 W 66 S 67 W 67 Edition 1968 Addenda S 68 W 68 S 69 W 69 5 70 W 70
- Prior to the Winter 1977 Addenda, Subsection NCA was designated NA ATTACHf4EllT C
(
~
-,.,. j 1
~
prsicNATED ORIGINAL
~
Edition.
fl97,1 0 u.-a n By Addenda S'71 W 71 S 72 W 72 5 73 W 73 Edition 1974 Addenda S 74 W 74 S 75 W 75 5 76 W 76 Edition 1977 Addends S 77 W 77 S 78 ASME Boiler and Pressure Code 50.55a(b)(2)and
~.
Section XI, Division 1 50.55a(g)
Addenda S 70 W 70 Edition 1971 Addenda S 71 W 71 S 72 W 72 S 73 W 73 Edition 1974 l
Addenda S 74 W 74 S 75 i
Edition 1977 Addenda S 77 l
l
'W 77 S 78 1
s IEEE-279 dtd August 30, 1968 and June 3, 1971, Criteria for 50.55a(h)
Protection Systems for tiuclear Generating Stations American Standard Code for Pressure Piping - ASA B31.1 50.55a(d) 1955 Edition U.S.A. Standard Code for Pressure Piping USAS B31.1.0-50.55a(d) 1967 Edition Addenda A, B & C.
l, U.S.A. Standard Code for Pressure Piping USAS B31.7 50.55a(d) 1969 Edition Addenda A, B & C Draft ASME Code for Pumps and Valves for Nuclear Power 50.55a(e)
I dated November 1968 and 1 Addenda dated 1970 ASA B31.1 Code Cases ti-1 through N-13.
50.55a(d)
American Society for Testing Materials (ASTM)
~
i Part 50 Standard Recommended Practice for Surveillance App, H Tests for Nuclear Reactor Vessels, ASTM ll.B.
Designation:,E-185 -73 Amatican National Standard N45.4-1972, Leakage App. J Rate Testing of Containment Structures for Ill.A.3.a.
Nuclear Reactors, March 16, 1972.
L' i
NRA, High Power Rifle Rules book, Mar.15, Part 73 App. B 1976 IV.B.
"NRC Target Manufacturer Index", December 1976 App. B IV.C.2 -n.2 1AEA INFCIRC/225/Rev. 1,"The Physical Part 110.43 Protection of Nuclear Material" (a)(1)
.