Text
-
4
' Bingham-Willamette Company A Division of Guy F Atkinson Company November 12, 1981 Regional Administration IShhhbl3 office of Inspection and Enforcement
{#
United States Nuclear Regulatory Commiss'.on i
Region IV l
!h[ ! b!bb!
611 Ryan Plaza Drive, Suite 1000 l
, m l,co,_4 g Arlington, TX 76011 Attention:
Mr. John T. Collins
!?gg.g.
s OEC gg 7gg
Reference:
Noncomplianco Part 21
%,, * 'alin
/
Gentlemen:
5 u,
j
(
Binghan.-Willamette Company has manufactured and shi ged two
/
auxiliary feed-water pumps for installation at the Beav.er Va ne [
No. 2 Nuclear Station which may contain defective impell h e~ar rings.
These two assemblies were shipped to Stone and Webster Engineering Corporation on BWC Sales Order No.'s 230702/3.
BWC has detected an impeller wear ring cracking condition at the securring pin hole juncture on various impeller stages on a sister pump element assembly (pump 230701).
Pumps 230702/3 possibly have the same cracked condition.
Should this condition exist on these pumps, there is a potential for complete ring. failure and a loss if~ performance, although the pumps would continue to run for an indefinite period of time at the reduced performance.
BWC first obtained information pertaining to this defect on September 10, 1981, while pump 230701 was at Terry Steam Turbine and confirmed that information at our Portland facility on November 10, 1981.
BWC is currently evaluating other pumps that have shipped or are in process that may have the same condition.
This evaluation is expected to be complete by December 15, 1981.
As part of our corrective action, we have requested the 230702/3 pumps be returned to our Portland factory for the purpose of replacing the wear rings on all impellers.
We anticipate this action to be complete by December 31, 1981.
Should you~ require any additional information, please contact us.
Very truly yours, BINGHAM-WILLAMETTE30MPANY h2 52 8111[2"5 k/
a PDR Dale F.
Patty bh President and General Manager 2800 N.W. Front Avenue Post Office Box 10247
- Portland, Oregon 97210 U.S.A. - (503) 226-5200 Telex: 360-516 TWX: 910-464-8031 sneveport. to s.ana u s A evnaty. ent sh ceiomc<a canada camcW;e Omam carada. Edmrfron. Am,da Cauda. Pemoone. Enf and p.4,
_