Text
_
FINAL ENVIRONMENTAL REPORT g
GD GRAAD GULF l
GRAND GULF O
NUCLEAR STATION UNITS 1 AND 2
t MISSISSIPPI POWER & LIGHT COMPANY MIDDLE SOUTH ENERGY, INC.
MIDDLE SOUTH UTILITIES SYSTEM g
AMENDMENT 8 C
. ~ _ _ - _ _. ~ _. _ _ _, - _ _ _ _ _. _ _ _
MISSISSIPPI POWER & LIGHT CPMPANY
('M Helping Build Mississippi
()
Edum M ddB P. O. B OX 164 0. J AC K S O N, MIS SIS SIP PI 3 9 2 05
"$$$rYNUepf,"
December 18, 1981 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C.
20555 Attention:
Mr. Harold R. Denton, Director
Dear Sir:
SUBJECT:
Grand Gulf Nuclear Station Units 1 and 2 Docket Nos. 50-416 and 50-417 File 0260/0277/M-900.0 Amendment 8 to the Final Environmental Report AECM-81/461 Attached are forty-one copies and three notorized originals of Amendment 8 to the Application for Licenses for Grand Gulf Nuclear Station, Units 1 and 2, in the matter of the Final Environmental Report (FER). Amendment 8 consists of the deletion of Sr-90 analysis on soil samples (Section 6.1.5.2.11), additional information on the Grand Gulf
(
s
(_)
Nuclear Station Meteorology System (Section 6.1.3.1), and revisions to the Chapter 2 Table of Contents.
Kourstruly, y
- \\
)
()
& !/ < ftv t
JPM:lm d
Attachments cc:
Mr. N. L. Stampley Mr. G. B. Taylor Mr. R. B. McGehee Mr. T. B. Conner Mr. Richard C. DeYoung, Director Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.
20555
,/ 3 i
\\
G' AE2Z1 Member Middle South Utilities System
_=
l L
BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION i
DOCKET NOS. 50-416 AND 50-417
)-
i j
IN THE MATTER OF l'
l 4
MISSISSIPPI POWER & LIGHT COMPANY and MIDDLE SOUTH ENERGY,-INC.
and SOUTH MISSISSIPPI ELECTRIC POWER ASSOCIATION i
4 AMENDMENT NO. 8 TO l
APPLICATION FOR LICENSES
(
(FINAL ENVIRONMENTAL REPORT) 1 Mississippi-Power & uight Company for itself and on behalf of Middle South Energy, Inc. and South Mississippi Electric Power Association 4
herewith files this Amendment No. 8 to their Application for Licenses in the form of the' deletion of Sr-90 analysis on soil samples (Section I
6.1.5.2.11), additional information on the Grand Gulf Nuclear Station lieteorology System (Section 6.1'.3.1), and revisions to the Chapter 2 Table of Contents.
~
Respectfully submitted, Mississippi Power & Light' Company f~,
i e
j BY
( /'hkD -
.d
'j-
- PT '*cG'a'bghy / Jr.
.ssistant Vice President s
Nuclear Production
O STATE OF MISSISSIPPI COUNTY OF HINDS J. P. McGaughy, Jr., being duly sworn, states that he is Assistant Vice President - Nuclear Production of Mississippi Power & Light Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission this Amendment No. 8 to the Application for Licenses (Final Environmental Report) on behalf of Company, Middle South Energy, Inc. and South Mississippi Electric Power Association; that he signed the forgoing amendment as Assistsnt Vice President -
l Nuclear Production of Mississippi Power & Light Company; and that the statements made and the matters set forth therein are true and correct to the best of his knowledge, information, and belief.
e 1
([
J.P.McG5ugfy{lJr.
SUBSCRIBED AND SWORN TO before me, Aa Notary Public, in and for the County and State above named, this
'i day of Dscs%LA, 1981.
(SEAL)
O l
Y Notary Public i
My commission expires:
13 R M u4Aq 1985 rh
GG ER MISSISSIPPI POWER & LIGHT COMPANY GRAND GULF NUCLEAR STATION UNITS 1 AND 2 DOCKET NOS. 50-416 AND 50-417 AMENDMENT NO. 8 INSTRUCTIONS FOR FILING AMENDMENT NO.
8, 12/81 Remove and insert the ER pages and tables listed below.
Dashes (---) in the remove or insert column indicate no action required.
Remove Insert VOLUME 1 Page Revision Index Page Revision Index Pages 1 through 24 Pages 1 through 24 VOLUME 2 Chapter 2 Table of Contents Pages 2-i/ii through 2-xxix/-
VOLUME 3 Page 6.1-11/12 Page 6.1-11/12 Page 6.1-13/13a Page 6.1-13/13a Page 6.1-13b/-
Page 6.1-29/30 Page 6.1-29/30 Table 6.1.9 (Sheet 1)
Table 6.1.9 (Sheet 1)
Table 6.1.9 (Sheet 2)
Table 6.1.9 (Sheet 2)
Table 6.1'.9 (Sheet 3)
VOLUCE 4 At the end of Volume 4 insert the following in the order shown:
l 1.
Amendment 8 tab 2.
Transmittal letter 3.
Instructions for filing l
O Amend. 8 12/81 l
l co ER PAGE REVISION INDEX A dash in the amendment column means that the page is a part of the initial issue of the ER and has not been revised to date.
Page Amendment
SUMMARY
OF TABLE OF CONTENTS i
ii iii iv QUESTIONS AND RESPONSES TABLE OF CONTENTS Q&R-i 5
Q&R-ii 5
PAGE REVISION INDEX 1
8 2
8 O
3 8
4 8
5 8
6 8
7 8
8 8
9 8
10 8
11 8
12 8
13 8
14 8
15 8
16 8
17 8
18 8
19 8
20 8
21 8
22 8
23 8
24 8
O Amend. 8 12/81 1
GG ER CHAPTER 1 PAGE REVISION INDEX Page Ame.ndn.ent Page Amendment Page Amendment 1-i 1
Table 1.1.18 1.1A-32 1-ii 1
Sht. 1 1
1.1A-33 1-iii 1
Sht. 2 1
1.1A-34 1-iv Sht. 3 1
1.1A-35 1.1-1 1
Table 1.1.19 1.2-1 1.1-2 1
Sht. 1 1
1.3-1 1
1.1-3 1
Sht. 2 1
Table 1.3.1 1
1.1-4 1
Fig. 1.1-1 Table 1.3.2 1
1.1-5 1
Fig. 1.1-2 1.1-6 1
Fig. 1.1-3 1
1.1-7 1
Fig. 1.1-4 1
1.1-7a 1
Fig. 1.1-5 1
1.1-7b 1
Fig. 1.1-6 1
1.1-8 1
Appendix A 1.1-9 1.1A-1 1.1-10 1
1.1A-2 1.1-11 1.1A-3 1.1-12 1.1A-4 1.1-13 1
1.1A-5 1.1-14 1
1.1A-6 Table 1.1.1 1
1.1A-7 O-Table 1.1.2 1
1.1A-8 Table 1.1.3 1
1.1A-9 Table 1.1.4 1
1.1A-10 Table 1.1.5 1
1.1A-11 Table 1.1.6 1
1.1A-12 Table 1.1.7 1
1.1A-13 Table 1.1.8 1
1.1A-14 Table 1.1.9 1
1.1A-15 Table 1.1.10 1
1.1A-16 i
Table 1.1.11 1.1A-17 Sht. 1 1.1A-18 1.1A-19 Sht. 2 Table 1.1.12 1.1A-20 Sht. 1 1
1.1A-21 Sht. 2-1 1.1A-22 l
Table 1.1.13 1.1A-23 Sht. 1 1
1.1A-24 1
Sht. 2 1
1.1A-25 Table 1.1.14 1
1.1A-26 Table 1.1.15 1
1.1A-27 Table 1.1.16 1.1A-28 Sht. 1 1
1.1A-29 Sht. 2 1
1.1A-30 Table 1.1.17 1
1.1A-31 V'O Amend. 8 12/81 2
GG ER CHAPTER 2
(
PAGE REVISION INDEX Page Amendment Page Amendment Page Amendment 2-i 1
2.1-16 1
Table 2.1.24 2-ii 2.1-17 Table 2.1.25 2-iii 2.1-18 Table 2.1.26 2-iv 1
2.1-19 Table 2.1.27 2-v 2.1-20 Table 2.1.28 2-vi 2.1-21 Table 2.1.29 2-vii 2.1-22 Table 2.1.30 2-viii 2.1-23 Table 2.1.31 2-ix Table 2.1.1 Table 2.1.32 2-x Sht. 1 Table 2.1.33 2-xi Sht. 2 Table 2.1.34 2-xii Sht. 3 Table 2.1.35 2-xiii Sht. 4 Table 2.1.36 2-xiv Table 2.1.2 Table 2.1.37 2-xv Sht. 1 Table 2.1.38 2-xvi Sht. 2 Table 2.1.39 2-xvii Sht. 3 Table 2.1.40 2-xviii Table 2.1.3 Table 2.1.41 2-xix Sht. 1 Table 2.1.42 2-xx Sht. 2 Table 2.1.43 2-xxi Sht. 3 Table 2.1.44 D
2-xxii Sht. 4 Table 2.1.45 d
2-xxiii Table 2.1.4 Table 2.1.46 2-xxiv 5
Sht. 1 Table 2.1.47 2-xxv Sht. 2 Table 2.1.48 2-xxvi Sht. 3 Table 2.1.49 2-xxvii 5
Table 2.1.5 Table 2.1.50 2-xxviii 6
Table 2.1.6 Table 2.1.51 2-xxix Table 2.1.7 Table 2.1.52 2.1-1 5
Table 2.1.8 Table 2.1.53 2.1-la 5
Table 2.1.9 Table 2.1.54 2.1-2 Table 2.1.10 Table 2.1.55 2.1-3 Table 2.1.11 Table 2.1.56 2.1-4 Table 2.1.12 Table 2.1.57 2.1-5 Table 2.1.13 Table 2.1.58 2.1-6 Table 2.1.14 Table 2.1.59 2.1-7 Table 2.1.15 Table 2.1.60 2.1-8 5
Table 2.1.16 Table 2.1.61 2.1-9 Table 2.1.17 Table 2.1.62 2.1-10 Table 2.1.18 Table 2.1.63 2.1-11 Table 2.1.19 Table 2.1.64 2.1-12 Table 2.1.20 Table 2.1.65 2.1-13 Table 2.1.21 Table 2.1.66 2.1-14 Table 2.1.22 Table 2.1.67 2.1-15 1
Table 2.1.23 Table 2.1.68 C
Amend. 8 12/81 3
GG ER CHAPTER-2 PAGE REVISION INDEX (CONT'D)
Page Amendment Page
-Amendment Page Amendment Table 2.1.69 2.2-35
=-
2.2-80 Table 2.1.70 2.2-36 2.2-81 Table 2.1.71 2.2-37 2.2-82 Sht. 1 2.2-83 2.2-38 Sht. 2 2.2-84 2.2-39 Table 2.1.72 Fig. 2.2-1 2.2-40 Fig. 2.1-1 2.2-41 Fig. 2.2-2 Fig. 2.1-2 Fig. 2.2-3 2.2-42 Fig. 2.1-3 Fig. 2.2-4 2.2-43 Fig. 2.1-4 Fig. 2.2-5 2.2-44 Fig. 2.1-5 Fig. 2.2-6 2.2-45 Fig. 2.2-7 2.2-1 2.2-46 Fig. 2.2-8 2.2-2 2.2-47 Fig. 2.2-9 2.2-3 2.2-48 Fig. 2.2-10 2.2-4 2.2-49 Fig. 2.2-11 2.2-5 2.2-50 Fig. 2.2-12 2.2 2.2-51 Fig. 2.2-13 2.2-7 2.2-52 2.2-8 2.3-1 2.2-53 2.2-9 2.3-2 2.2-54 2.2-10 2.2-55 2.3-3 I~')
2.2-57 2.2-11 2.3-4 2.2-56
\\s-2.2-12 2.3-5 2.2-13 2.3-6 2.2-58 2.2-14 2.3-7 2.2-59 2.3-8 2.2-15 2.2-60 2.2-16 2.3-9 2.2-61 2.2-62 2.3-10 2.2-17 2.3-11 2.2-18 2.2-63 2.3-12 2.2-19 2.2-64 2.3-13 2.?-20 2.2-65 2.3-14 2.2-21 2.2-66 2.3-15 2.2-22 2.2-67 2.3-16 2.2-23 2.2-68 2.2-69 2.3-17 2.2-24 2.2-70 2.3-18 2.2-25 2.3-19 2.2-26 2.2-71 2.2-27 2.2-72 2.3-20 2.3-21 2.2-28 2.2-73 2.3-22 2.2-29 2.2-74 2.3-23 2.2-30 2.2-75 2.3-24 2.2-31 2.2-76 2.3-25 2.2-32 2.2-77 Table 2.3.1 2.2-33 2.2-78 Table 2.3.2 2.2-34 2.2-79 O
Amend. 8 12/81 4
GG ER CHAPTER 2 O
PAGE REVISION INDEX (CONT'D)
V Page Amendment Page Amendment Page Amendment i
Table 2.3.3 Table 2.3.48 Sht. 6 Table 2.3.4 Table 2.3.49 Sht. 7 Table 2.3.5 Table 2.3.50 Sht. 8 Table 2.3.6 Table 2.3.51 Sht. 9 Table 2.3.7 Table 2.3.52 Table 2.3.61 Table 2.3.8 Table 2.3.53 Sht. 1 Table 2.3.9 Table 2.3.54 Sht. 2 Table 2.3.10 Table 2.3.55 Sht. 3 Table 2.3.11 Table 2.3.56 Sht. 4 Table 2.3.12 Table 2.3.57 Sht. 5 Table 2.3.13 Sht. 1 Sht. 6 Table 2.3.14 Sht. 2 Sht. 7 Table 2.3.15 Sht. 3 Sht. 8 Table 2.3.16 Sht. 4 Sht. 9 Table 2.3.17 Sht. 5 Table 2.3.62 Table 2.3.18 Sht. 6 Table 2.3.63 Table 2.3.19 Table 2.3.64 Sht. 7 Table 2.3.20 Sht. 8 Table 2.3.65 Table 2.3.21 Sht. 9 Table 2.3.66 Table 2.3.22 Table 2.3.58 Table 2.3.67 Table 2.3.23 Sht. 1 Table 2.3.68 O
Table 2.3.24 Sht. 2 Table 2.3.69 O
Table 2.3.25 Sht. 3 Table 2.3.70 Table 2.3.26 Sht. 4 Table 2.3.71 Table 2.3.27 Sht. 5 Table 2.3.72 Table 2.3.28 Sht. 6 Table 2.3.73 Table 2.3.29 Sht. 7 Table 2.3.74 Table 2.3.30 Sht. 8 Table 2.3.75 Table 2.3.31 Sht. 9 Table 2.3.76 Table 2.3.32 Table 2.3.59 Table 2.3.77 Table 2.3.33 Sht. 1 Table 2.3.78 Table 2.3.34 Sht. 2 Table 2.3.79 Table 2.3.35 Sht. 3 Table 2.3.80 Table 2.3.36 Sht. 4 Table 2.3.81 Table 2.3.37 Sht. 5 Table 2.3.82 Table 2.3.38 Sht. 6 Table 2.3.83 Table 2.3.39 Sht. 7 Table 2.3.84 Iable 2.3.40 Sht. 8 Table 2.3.85 Table 2.3.41 Sht. 9 Table 2.3.86 Table 2.3.42 Table 2.3.60 Table 2.3.87 Table 2.3.43 Sht. 1 Table 2.3.88 Table 2.3.44 Sht. 2 Table 2.3.89 Table 2.3.45 Sht. 3 Table 2.3.90 Table 2.3.46 Sht. 4 Table 2.3.91 Table 2.3.47 Sht. 5 Table 2.3.92 O
Amend. 8 12/81 5
GG ER
' CHAPTER 2 OQ PAGE REVISION INDEX (CONT'D)
Page Amendment Page Amendment'_Page Amendment Fig. 2.3-5 Table 2.3.93 Table ~2.3.128D Fig. 2.3-6 Table 2.3.94 Table 2.3.128E Fig. 2.3-7 Table 2.3.95 Table 2.3.128F Fig. 2.3-8 Table 2.3.96 Table 2.3.128G Fig. 2.3-9 Table 2.3.97
. Table 2.3.129A Fig. 2.3-10 Table 2.3.98 Table 2.3.129B Table 2.3.99 2.4-1 Table 2.3.129C 2.4-2 5
Table 2.3.100 Table 2.3.129D 2.4-3 5
Table 2.3.101 Table 2.3.129E 2.4-4 l'
Table 2.3.102 Table 2.3.129F 2.5-5 1
Table 2.3.103 Table 2.3.130.
2.4-6 5
Table 2.3.104 Table 2.3.131 2.4-7 1
Table 2.3.105 Table 2.3.132 2.4-8 1
Table 2.3.106 Table 2.3.133 2.4-9 1
. Table 2.3.107 Table 2.3.134 2.4-10 5
Table 2.3'.108 Table 2.3.135 2.4-11 6
Table 2.3.109 Table 2.3.136
. Table 2.4.1 Table 2 3.110 Table.2.3.137 Table 2.4.2 Table 2.3.111 Table 2'.3.138 Table 2.4.3 Table 2.3.112 Table 2.3.139 Table 2.3.140 Sht.- 1 5.
Table 2.3.113 O
Sht. 2 5
Table 2.3.114 Table 2.3.141 Table 2.4.4 5
Table 2.3.115 Table 2.3.142 Table 2.4.5-Table 2.3.116 Table 2.3.143 Table ~2.4.6 Table 2.3.117 Table 2.3.144 Table 2.3.145 Table 2.4.7 5
Table 2.3.118 Table 2.4.8 Table 2.3.119 Table 2.3.146 Table 2.4.9 Table 2.3.120 Table 2.3.147 Table-2.4.10 Table 2.3.148 Table 2.3.121 Table 2.4.11 Table 2.3.149 Table 2.3.122 Table 2.4.12 Table 2.3.150 Table 2.3.123 Sht. 1 Table 2.3.151 Table 2.3.124
-Sht. 2 Table 2.3.152 Table 2.3.125 Table 2.4.13 Table 2.3.153 Table 2.3.126 Table 2.4.14 Table 2.3.154 Table 2.3.127A Table 2.4.15 Table 2.3.155 Table 2.3.127B Fig. 2.4-1 Table 2.3.127C Table 2.3.156 Fig. 2.4-2 5
Table 2.3.157 Table 2.3.127D Fig. 2.4-3 Table 2.3.158 Table 2.3.127E Fig. 2.4-4 Table 2.3.159 Table 2.3.127F Fig. 2.4-5 Table 2.3.160 Table 2.3.127G Fig. 2.4-6 Fig. 2.3-1 Table 2.3.127H Fig. 2.4-7 Fig. 2.3-2 Table 2.3.128A Fig.~2.4-8 Table 2.3.128B Fig. 2.3-3 Fig. 2.4-9 Table 2.3.128C-Fig. 2.3-4 v}.
f F
Amend. 8 12/81' 6
GG ER CHAPTER 2
)
PAGE REVISION INDEX (CONT'D)
Page Amendment Fig. 2.4-10 Fig. 2.4-11 Sht. 1 Sht. 2 Sht. 3 Sht. 4 Sht. 5 Fig. 2.4-12 Fig. 2.4-13 Fig. 2.4-14 Fig. 2.4-15 6
2.5-1 2.5-2 2.5-3 2.5-4 Fig. 2.5-1 Fig. 2.5-2.
Fig. 2.5-3 Fig. 2.5-4 2.6-1 2.6-2 2.6-3 Fig. 2.6-1 2.7-1 2.7-2 2.7-3 2.7-4 2.7-5 2.7-6 2.7-7 2.7-8 Table 2.7.1 Fig. 2.7-1 Fig. 2.7-2 Fig. 2.7-3 Fig. 2.7-4 Fig. 2.7-5 Fig. 2.7-6 Fig. 2.7-7 Fig. 2.7-8 Fig. 2.7-9 Fig. 2.7-10 O
Amend. 8 12/81 7
GG ER CHAPTER 3 PAGE REVISION INDEX Page Amendment 'Page Amendment Page Amendment 3-i 1
3.5-9 Sht. 3 3-ii 3.5-10 Table 3.6.3a 3-iii 7
3.5-11 Sht. 1 5
3-iv 1
3.5-12 Sht. 2 5
3-v 5
3.5-13 Table 3.6.3b 3-vi 3.5-14 Sht. 1 5
3-vii 3.5-15 Sht. 2 5
3-viii Table 3.5.1 Table 3.6.4 3.1-1 Sht. 1 Sht. 1 3.1-2 Sht. 2 Sht. 2 Fig. 3.1-1 Sht. 3 Table 3.6.5 3.2-1 Sht. 4 Sht. 1 3.2-2 Sht. 5 Sht. 2 3.2-3 Sht. 6 Fig. 3.6-1 Fig. 3.2-1 Table 3.5.2 3.7-1 3.3-1 5
Table 3.5.3 3.7-2 3.3-2 1
Sht. 1 3.7-3 1
3.3-3 5
Sht. 2 3.7-4 1
Table 3.3.1 Table 3.5.4 Table 3.7.1.
Sht. 1 5
Sht. 1 3.8-1 I~')
Sht. 2 5
Sht. 2 3.9-1 (d
Table 3.3.2 Table 3.5.5 3.9-2 Fig. 3.3-1 5
Table 3.5.6 3.9-3 3.4-1 5
Fig. 3.5-1 3.9-4 1
3.4-2 Fig. 3.5-2 3.9-4a 1
'3.4-3 5
Fig. 3.5-3 3.9-5 3.4-4 5
Fig. 3.5-4 3.9-6 1
3.4-5 5
Fig. 3.5-5 3.9-6a 1
Table 3.4.1 3.6-1 7
3.9-7 Table 3.4.2 5
3.6-2 7
3.9-8 1
Table 3.4.3 5
3.6-3 7
3.9-8a 1
Table 3.4.4 5
3.6-4 7
3.9-9 Fig. 3.4-1 5
3.6-4a 7
3.9-10 Fig. 3.4-2 3.6-5 5
3.9-11 Fig. 3.4-3 3.6-6 5
3.9-12 1
Fig. 3.4-4 3.6-7 7
3.9-13 Fig. 3.4-5 3.6-8 7
3.9-14 5
i 3.5-1 Table 3.6.1 Table 3.9.1 3.5-2 Sht. 1 7
Table 3.9.2 3.5-3 Sht. 2 7
Table 3.9.3 3.5-4
'Sht. 2a 7
Table 3.9.4 3.5-5 Sht. 3 Fig. 3.9-1 3.5-6 Sht. 4 7
Fig. 3.9-2 3.5-7 Table 3.6.2 Fig. 3.9-3 3.5-8 Sht. 1 Fig. 3.9-4 p
Sht. 2 O
Amend. 6 12/81 8
GG ER CHAPTER 3 PAGE REVISION INDEX (CONT'D)
Page Amendment Fig. 3.9-5 Fig. 3.9-6 Fig. 3.9-7 Fig. 3.9-8 O
O Amend. 8 12/81 9
GG ER CHAPTER 4
()
PAGE REVISION INDEX j
Page Amendment Page Amendment 4-i Appendix A 4-ii 1
4.5A-1 4-iii 4.5A-2 4-iv 4.5A-3 4.1-1 5
4.5A-4 4.1-2 4.5A-5 4.1-3 4.5A-6 4.1-4 4.5A-7 4.1-5 4.5A-8 4.1-6 4.5A-9 4.1-7 4.5A-10 4.1-8 4.5A-11 4.1-9 4.5A-12 4.1-10 4.5A-13 4.1-11 4.5A-14 4.1-12 4.1-13 4.1-14 4.1-15 4.1-16 1
Os 4.1-16a 1
4.1-17 5
4.1-18 4.1-19 4.1-20 4.1-21 4.1-22 4.1-23 4.1-24 4.1-25 4.1-26 1
Table 4.1.1 5
Table 4.1.2 Fig. 4.1-1 Fig. 4.1-2 Fig. 4.1-3 Fig. 4.1-4 Fig. 4.1-5 4.2-1 4.2-2 4.2-3 1
4.2-4 1
4.3-1 4.4-1 4.5-1 O
i Amend. 8 12/81 10
GG ER CHAPTER 5
()
PAGE REVISION INDEX Page Amendment Page Amendment Page Amendment 5-i 5
Sht. 4 5.2-8 5-ia 5
Sht. 5 5.2-9 5-ii 5
Table 5.1.5 5.2-10 5-iii 5
Table 5.1.6 5.2-11 5-iv 1
Table 5.1.7 Table 5.2.1 5-v 5
Table 5.1.8 Table 5.2.2 5-vi 7
Table 5.1.9 Table 5.2.3 5-vii 5
Table 5.1.10 Table 5.2.4 5.1-1 5
Table 5.1.11 5
Table 5.2.5 5.1-2 5
Table 5.1.12 5
Table 5.2.6 5.1-3 5
Table 5.1.13 5
Table 5.2.7 5.1-4 5
Table 5.1.14 5
Table 5.2.8 5.1-5 5
Table 5.1.15 5
Table 5.2.9 5.1-6 5
Table 5.1.16 5
Fig. 5.2-1 5.1-7 5
Table 5.1.17 5
Fig. 5.2-2 5.1-8 5
Table 5.1.18 5
Appendix A 5.1-9 5
Table 5.1.19 5
5.2A -
5.1-10 5
Table 5.1.20 5
5.2A-2 5.1-11 5
Table 5.1.21 5
5.2A-3 5.1-12 5
Table 5.1.22 5
5.2A-4
[]
5.1-13 5
Table 5.1.23 5
Table 5.2A.1
\\,,
5.1-13a 5
Table 5.1.24 1
Sht. 1 5.1-13b 5
Fig. 5.1-1 5
Sht. 2 5.1-13c 5
Fig. 5.1-2 5
Sht. 3 5.1-14 Fig. 5.1-3 5
Fig. 5.2A-1 l
5.1-15 Fig. 5.1-4 5
5.3-1 5
l 5.1-16 Fig. 5.1-5 5
5.3-2 5
I 5.1-17 Fig. 5.1-6 5
5.3-3 5
5.1-18 Fig. 5.1-7 5
5.3-4 5
5.1-19 Fig. 5.1-8 5
5.3-5 5
5.1-20 5
Fig. 5.1-8a 5
5.3-6 5
5.1-21 5
Fig. 5.1-9 5.3-7 5
5.1-22 5
Appendix A 5.3-8 5
5.1-23 5
5.1A-1 5
5.3-9 5
5.1-24 5
5.1A-2 5
5.3-10 5
5.1-25 5
5.1A-3 5
5.3-11 5
Table 5.1.la 5
Appendix B Table 5.3.1 7
Table 5.1.lb 5
5.1B-1 5
Table 5.3.la 5
Table 5.1.2a 5
5.2-1 Table 5.3.lb 5
Table 5.1.2b 5
5.2-2 Table 5.3.2 5
Table 5.1.3 5.2-3 Table 5.3.3 5
Table 5.1.4 5.2-4 Table 5.3.4 5
Sht. 1 5.2-5 Table 5.3.5 5
Sht. 2 5.2-6 Table 5.3.6 5
l Sht. 3 Appendix A 5.2-7 l
5.3A-1 l
%J Amend. 8 12/81 11
i t
3 GG l'
CHAPTER 5 PAGE REVISION INDEX (CONT'D) i t
4 Page Amendment r
l' 5.4-1 I
Table 5.4.1 5.5-1 5.5-2 1
f 5.5-3 1
1 5.5-4 1
t t
5.6-1 1
4 l
5.6-2 1
l 5.6-3 1
5.7-1 5.8-1 5.8-2 1
i 3
i i
1
[
E b
~
i i
i I
h i
~
i 1
)
1 1
I l
l t
4 j-t i
I@
4 Amend. 8 12/81 12 l
+ - - -
--n.
nn..-
GG ER CHAPTER 6 PAGE REVISION INDEX Page Amendment Page Amendment Page Amendment 6-i Fig. 6.1-4 Sht. 2 6-ii Table 6.1.3 Fig. 6.1-5 6-iii Sht. 1 Fig. 6.1-6 6-iv Sht. 2 6.2-1 6-v Table 6.1.4 6.3-1 6-vi 2
Sht. 1 6.4-1 2
6-vii 2
Sht. 2 Table 6.4.1 6.1-1 Table 6.1.5 Sht. 1 2
6.1-2 Table 6.1.6 Sht. 2 2
6.1-3 Table 6.1.7 Sht. 3 2
6.1-4 Sht. 1 Table 6.4.2 2
6.1-5 Sht. 2 Table 6.4.3 2
6.1-6 Table 6.1.8 Table 6.4.4 2
6.1-7 Sht. 1 Table 6.4.5 2
6.1-8 Sht. 2 Table 6.4.6 2
6.1-9 Table 6.1.9 Table 6.4.7 2
6.1-10 Sht. 1 8
Table 6.4.8 2
6.1-11 8
Sht. 2 8
Table 6.4.9 2
6.1-12 8
Sht. 3 8
Table 6.4.10 2
6.1-13 8
Table 6.1.10 Table 6.4.11 2
6.1-13a 8
Table 6.1.11 Table 6.4.12 2
6.1-13b 8
Table 6.1.12 Table 6.4.13 2
6.1-14 Table 6.1.13 Table 6.4.14 2
6.1-15 Table 6.1.14 Table 6.4.15 2
6.1-16 Table 6.1.15 Table 6.4.16 2
6.1-17 Table 6.1.16 Table 6.4.17 6.1-18 Table 6.1.17 Sht. 1 2
6.1-19 Table 6.1.18 Sht. 2 2
6.1-20 5
Table 6.1.19 Fig. 6.4-1 2
6.1-21 5
Table 6.1.20 Fig. 6.4-2 2
6.1-22 5
Table 6.1.21 Fig. 6.4-3 2
6.1-23 5
Table 6.1.22 6.1-24 Table 6.1.23 6.1-25 Table 6.1.24 6.1-26 Table 6.1.25 6.1-27 Table 6.1.26 6.1-28 2
Table 6.1.27 6.1-29 8
Table 6.1.28 6.1-30 2
Table 6.1.29 6.1-31 2
Table 6.1.30 6.1-32 2
Sht. 1 Table 6.1.1 Sht. 2 5
Sht. 1 Table 6.1.31 5
Sht. 2 Fig. 6.1-1 Table 6.1.2 Fig. 6.1-2 Sht. 1 Fig. 6.1-3 N
Amend. 8 12/81 13 i
1
't GG ER
}
CHAPTER 7 i
PAGE REVISION INDEX 4
i i
i i
Page Amendment 7-i 7-ii-7-iii' 7.1-1 7.1-2 7.1-3 l
7.1-4 I
7.1-5 7.1-6 7.1-7 7.1-8 7.1-9
-Table 7.1.1 Table 7.1.2 Table 7.1.3 Table 7.1.4 i
Sht. 1 I
Sht. 2 l
Sht. 3 l
7.2-1 l
7.3-1 Table 7.3.1 l
I r
P i
l Amend. 8 12/81 14
GG ER CHAPTER 8 PAGE REVISION INDEX
.Page Amendment Page f.nendment Page Amendment 8-i 1
8.lA-26 8.1A-71 8-ii 8.lA-27 8.lA-72 8-iii 8.1A-28 8.lA-73 8.1-1 8.lA-29 8.lA-74 8.1-2 1
8.lA-30 8.lA-75 8.1-3 5
8.lA-31 8.lA-76 8.1-4 5
8.1A-32 8.lA-77 8.1-5 1
8.1A-33 8.1A-78 8.1-6 1
8.1A-34 8.lA-79 8.1-7 1
8.lA-35 8.1A-80 8.1-8 1
8.1A-36 8.1A-81 8.1-9' 1
8.lA-37 8.1A-82 8.1-10 1
8.lA-38 8.1A-83 Table 8.1.1 8.lA-39 8.lA-84 Table 8.1.2 8.lA-40 8.lA-85 Table 8.1.3 8.lA-41 8.1A-86 Table 8.1.4 8.lA-42 8.lA-87 Table 8.1.5 8.lA-43 8.2-1 Fig. 8.1-1 8.lA-44 8.2-2 Appendix A 8.lA-45 8.lA-1 8.lA-46 p
f 8.1A-2 8.1A-47
('#
8.lA-3 8.lA-48 8.lA-4 8.1A-49 8.lA-5 8.lA-50 8.1A-6 8.lA-51 8.1A-7 8.lA-52 8.1A-8 5
8.1A -
8.lA-9 5
8.lA-54 8.1A-10 8.1A -
8.1A-11 8.lA-56 8.1A-12 8.1A-57 8.1A-13 8.1A-58 8.1A-14 8.1A-59 8.1A-15 8.lA-60 8.lA-16 8.lA-61 8.lA-17 8.lA-62 8.1A-18 8.lA-63 8.1A-19 8.lA-64 8.lA-20 8.lA-65 8.lA-21 8.lA-66 8.1A-22 8.lA-67 8.lA-23 8.1A-68 8.lA-24 8.lA-69 8.1A-25 8.lA-70
)
w/
Amend. 8 12/81 15 l
_.._ __..._. _ -__.~
f CG i
ER 1
CHAPTER 9 1
PAGE REVISION INDEX 2
1 1
l Page Amendment i
1 9-i 1
9-ii 9.1-1
)
9.2-1 9.2-2 1
9.2-3 1
l 1
l 9.2-4 9.2-5 Table 9.2.1 1
i Table 9.2.2 i
9.3-1 1
9.3-2 1
Table 9.3.1 Table 9.3.2 1
(
9.4 -
Table 9.4.1 Table 9.4.2 Table 9.4.3 Table 9.4.4 ll l
1 i
l t
i r-Amend. 8 12/81
--,---Wes*9r N eww whee we'
i GG-ER CHAPTER 10 PAGE REVISION INDEX Page Amendment Page Amendment 10-i Fig. 10.3-3 10-ii Appendix A l
10-iii 10.3A-1 10-iv 10.3A-2 10-v 10.3A-3 10-vi Table 10.3A-1 10.1-1 Table 10.3A-2 10.1-2 10.4-1 10.1-3 10.4-2 10.1-4 10.4-3 10.1-5 10.4-4 10.1-6 10.5-1 Table 10.1.1 10.5-2 Table 10.1.2 10.5-3 Sht. 1 10.5-4 Sht. 2 10.5-5 Sht. 3 10.5-6 Table 10.1.3 10.5-7 Table 10.1.4 Table 10.5.1 Fig. 10.1-1 10.6-1 4
Fig. 10.1-2 10.6-2
'~'J '
Fig. 10.1-3
-10.6-3 Fig. 10.1-4 10.7-1 10.2-1 10.8-1 10.2-2 10.9-1 10.2-3 10.9-2 Table 10.9.1 10.2-4 Fig. 10.9-1 10.2-5 10.10-1 10.2-6 10.2-7 Table 10.2.1 Table 10.2.2 Fig. 10.2-1 Fig. 10.2-2 Fig. 10.2-3 Fig. 10.2-4 10.3-1 10.3-2 10.3-3 10.3-4
'l 10.3-5 Table 10.3.1 i
Table 10.3.2 Fig. 10.3-1 Fig. 10.3-2
(
Amend. 8 12/81 17
...._..m._,
i, t
GG ER CHAPTER 11 I
O PAGE REVISION INDEX
\\j Page Amendment r
I J
11-i l
11-ii j.
11.1-1 1
1 11.1-2 i
11.2-1 11.2-2
-Table 11.2.1 t
,r Sht. 1 y
Sht. 2 1,
Sht. 3-p Sht. 4 Sht. 5
.l 11.3-1 6
1'
-f i
(
r 1
9 r
I
(
s f
I t
- r t
t l
i t
i t
l I
6 1O i
f Amend.-8 12/81 l
(
8 I
t i
?
4 GG ER j
CHAPTER 12 PAGE REVISION INDEX Page Ameltdment i
1.
12-i l
12.1-1 12.2-1 l
12.2-2 1
12.3-1 t
12.4-1 12.5-1 12.6-1 t
12.6-2 r
i t
12.7-1
+
l I
i i
i i
i l
1 e
l t
1 1
l l
I I
i i
(
i Amend. 12/81 i
.19 l
GG ER CHAPTER 13 PAGE REVISION INDEX Page Amendment 13-1 13-2 13-3 13-4 13-5 13-6 13-7
'13-8 13-9 13-10 13-11 13-12 13-13 13-14 13-15 13-16 13-17 13-18 13-19 13-20 0
13-21 13-22 13-23
'13-24 13-25 13-26 13-27 13-28 O
Amend. 8 12/81 20
GG ER QUESTIONS AND RESPONSES PAGE REVISION INDEX' Page Amendment Page Amendment Page Amendment Q&R 1.1-1 1
40 Location Map II-1 (001)
Q&R 1.1-2 1
41 Fuel Estimating Q&R 8.1-1 1
II-2 (001)
Program Q&R 1.1-3 1
II-3 (001) 1 Q&R 1.1-4 1
II-4 (001) 2 Q&R 8.1-2 1
II-5 (001) 3 Q&R 8.1-3 1
II-6 (001) 4 Q&R 4.1-1 1
II-7 (001) 5 Table 300.7.1 II-8 (001)
Sht. 1-1 II-9 (001) 6 Sht. 2 1
II-1 (002) 7 Sht. 3 1
II-2 (002) 8 Sht. 4 1
II-3 (002) 9 l
10 Sht. 5 1
II-4 (002) 11 Sht. 6 1
II-5 (002)
Sht. 7 1
II-6 (002) 12 Sht. 8 1
II-7 (002) 13 14 Q&R 3.9-1 1
II-8'(002)
Q&R 2.1-1 1
II-9 (002) 15 16 Q&R 2.2-1 1
II-1 (003)
()
17-Q&R 2.4-1 1
II-2 (003)
\\s,/
18 Q&R 3.3-1 1
II-3 (003)
Q&R 3.7-1 1
II-4 (003) 19 Q&R 5.1-1 1
II-5 (003) 20
.Q&R 8.1-4 1
II-6 (003) 21 Q&R 1.1-5 1
II-7 (003) 22 Q&R 5.1-2 1
II-8 (003) 23 Q&R 2.2-2 1-II-9 (003) 24 25 Q&R 2.2-3 1
II-1 (004)
Q&R 3.6-1 1
II-2 (004) 26 l
27 Q&R 3.6-2 1
II-3 (004)
Q&R 4.2-1 1
II-4 (004) 28 Q&R 5.3-1 1
- II-5 (004) 29 30 Q&R 5.6-1 1
II-6 (004) 31 Q&R 6.1-1 1
II-7 (004)
Q&R 12.2-1 1
II-8 (004) 32 Cover Letter II-9 (004) 33 NPDES Permit II-1 (005) 34 35 Application II-2 (005)
I-1 II-3 (005) 36 II-4 (005) 37 I-2 II-5 (005) 38 I-3 Fig. 3.3-1 II-6 (005) 39 II-7 (005)
II-8 (005)
! O Amend. 8 12/81 21
1 GG ER
-i QUESTIONS AND RESPONSES PAGE REVISION INDEX (CONT'D)
Page Amendment Page Amendment Page Amendment II-9 (005)
Q&R 2.4-5 3
Q&R 1.1-6 3
II-1 (006)
Q&R 11.1-1 3
Q&R 8.1-7 3
II-2 (006)
Q&R 11.1-2 3
Q&R 8.1-8 3
II-3 (006)
Q&R 4.1-2 3
Q&R 2.1-3 5
II-4 (006)
Q&R 4.2-3 3
Q&R 2.1-4 5
II-5 (006)
Q&R 5.5-3 3
Q&R 8.1-9 5
II-6 (006)
Q&R 5.3-2 5
Q&R 8.1-10 5
II-7 (006)
Q&R 5.3-3 5
Q&R 8.1-11 5
Table 1 II-8 (006)
Q&R 2.6-1 3
Table 2-II-9 (006)
Q&R 2.6-2 3
Table 3 II-1 (007)
Q&R 2.6-3 3
Fig. 1 II-2 (007)
Q&R 2.1-2 1
II-3 (007)
Q&R 12.2-2 5
Q&R 2.4-2 1
State of Mississippi Q&R 2.4-3 1
II-4 (007)
Water Pollution Q&R 3.3-2 1
II-5 (007)
Control Permit Q&R 3.3-3 1
II-6 (007)
II-7 (007) 1 Q&R 3.3-4 1
II-8 (007) 2 Q&R 3.4-1 1
II-9 (007)
Q&R 2.4-10 5
3 II-1 (008) 4 Q&R 2.4-11 5
II-2 (008) 5 Q&R 2.4-12 5
p(,)s II-3 (008)
Q&R 2.4-13 5
6 II-4 (008) 7 Q&R 2.4-14 5
II-5 (008) 8 Q&R 2.4-15 5
II-6 (008)
Q&R 2.4-16 5
9 Table 371.07.1 5
II-7 (008) 10 II-8 (008)
Table 371.07.2 11 Sht. 1 5
II-9 (008) 12 II-1 (009)
Sht. 2 5
13 II-2 ('JO9)
Sht. 3 5
14 II-3 (009) 15 Fig. 371.07-1 5
16 Fig. 371.07-2 5
II-4 (009) 17 Fig. 371.07-3 5
II-5 (009) 18 Fig. 371.07-4 5
II-6 (009)
II-7 (009) 19 Fig. 371.07-5 5
Fig. 371.07-6 5
II-8 (009) 20 Fig. 371.07-7 5
II-9 (009) 21 Q&R 3.6-3 3
Q&R 8.1-5 3
Fig. 371.07-8 5
Q&R 3.6-4 3
Q&R 8.1-6 3
Fig. 371.07-9 5
Q&R 2.2-4 3
Q&R-9.4-1 3
Fig. 371.07-10 5
Q&R 4.2-2 3
Q&R 9.4-2 3
Fig. 371.07-11 5
Q&R 5.5-1 3
Q&R 9.4-3 3
Appendix 317.07-A Q&R 5.5-2 3
Q&R 9.2-1 3
2.4C-1 Q&R 2.4-4 3
2.4C-2 Q&R 4.5-1 3
O Amend. 8 12/81 22
GG ER QUESTIONS AND RESPONSES PAGE REVISION INDEX (CONT'D)
Page Amendment Page Amendment Page Amendment 2.4C-3 2.4C-48 2.4C-93 2.4C-4 2.4C-49 2.4C-94 2.4C-5 2.4C-50 2.4C-95 2.4C-6 2.4C-51 2.4C-96 2.4C-7 2.4C-52 2.4C-97 2.4C-8 2.4C-53 2.4C-98 2.4C-9 2.4C-54 2.4C-99 2.4C-10 2.4C-55 2.4C-100 2.4C-11 2.4C-56 2.4C-101 2.4C-12 2.4C-57 2.4C-102 2.4C-13 2.4C-58 2.4C-103 2.4C-14 2.4C-59 2.4C-104 2.4C-15 2.4C-60 2.4C-105 2.4C-16 2.4C-61 2.4C-106 2.4C-17 2.4C-62 2.4C-107 2.4C-18 2.4C-63 2.4C-108 2.4C-19 2.4C-64 2.4C-109 2.4C-20 2.4C-65 2.4C-110
- 2. 4C-111 2.4C-21 2.4C-66 2.4C-22 2.4C-67 2.4C-112 O
2.4C-23 2.4C-68 2.4C-113
\\,,/
2.4C-24 2.4C-69 2.4C-114 2.4C-70 2.4C-115 2.4C-25 l
2.4C-26 2.4C-71 2.4C-116 2.4C-117 2.4C-27 2.4C-72 2.4C-73 2.4C-118 2.4C-28 2.4C-74 2.4C-119 2.4C-29 2.4C-120 2.4C-30 2.40-75 2.4C-121 2.4C-76 2.4C-31 2.4C-122 2.4C-77 2.4C-32 2.4C-78 2.4C-123 2.4C-33 2.4C-124 2.4C-79 2.4C-34 2.4C-80 Q&R 2.3-1 1
1 2.4C-35 Q&R 2.3-2 1
2.4C-36 2.4C-81 Fig. 372.1-1 1
2.4C-37 2.4C-82 Fig. 372.1-2 1
2.4C-38 2.4C-83 Fig. 372.1-3 1
2.4C-84 2.4C-39 2.4C-85 Fig. 372.1-4 1
2.4C-40 Fig. 372.1-5 1
2.4C-86 2.4C-41 2.4C-87 Q&R 2.3-3 1
2.4C-42 Q&R 2.3-4 1
2.4C-43 2.4C-88 Fig. 372.2-1 1
2.4C-89 2.4C-44 Fig. 372.2-2 1
2.4C-90 2.4C-45 Q&R 2.3-5 1
2.4C-46 2.4C-91 Table 372.3.1 1
2.4C-92 2.4C-47 k
Amend. 8 12/81 23
. GG _ _
ER QUESTIONS AND RESPONSES
)
PAGE REVISION INDEX~(CONT'D)
Pagez Amendment Page Amendment' Q&R 5.2-1 1
Fig. 372.5-8 1
Q&R 5.2-2 1
Fig. 372.5-9 1
Q&R 5.2-3 1
Q&R 6.1-5 1
Q&R 6.1-2 1.
'Q&R 6.1-6 1
Q&R 6.1-3 1
Q&R 6.1-7 1
Q&R 6.1-4 1
.Q6dl 3. 7-2 5
Table 372.5.1 1
Q&R 3.7-3 5
Table 372.5.2 1
Q&R 3.7-4 5
Table 372.5.3 1
Q&R 2.4-6 4
Table 372.5.4 1
Q&R.2.4-7 4
Table 372.5.5 1
Q&R 4.1-3 4
-Table 372.5.6 1.
Q&R'2.4-8 4
Table 372.5.7 1-Q&R 2.4-9 4
Table 372.5.8 1
Q&R 10.2-1 4
Table 372.5.9 1
Q&R 10.2-2 4
Table 372.5.10 1
Fig. 1 4
-Table 372.5.11 1
Fig. 2 4
Table 372.5.12
'l Table 372.5.13-1 Table 372.5.14 1
[)
Table 372.5.15 1
-U Table 372.5.16 1
Table 372.5.17 1
Table 372.5.18 1
Table 372.5.19 1
. Table 372.5.20 1
Table 372.5.21 1
Table'372.5.22 1
Table 372.5.23 1
Table 372 5.24 1.
Table 37
.25 1
Table 372
.26 1
Table 372.a.27 1
Table 372.5.28 1
Table 372.5.29 1
Table 372.5.30 1
Table 372.5.31 1-Fig.-372.5-1 1
Fig. 372.5-2 1
Fig. 372.5-3
'l Fig. 372.5-4 1
Fig. 372.5-5 1
Fig. 372.5-6 1
Fig.'372.5-7 1
O Amend. 8 12/81 24
GG ER
[~')
Surface MRI 302 Tipping bucket rain gauge
%d 33 feet MRI 1090-2 Air bearing anemometer MRI 1074-2 Wind System MRI 809 Delta temperature system (with reference temperature)
MRI 830 Relative humidity sensor MRI 830 Temperature sensor 133 feet MRI 1074-2 Wind system MRI 809 Delta temperature system 162 feet MRI 1074-2 Wind System MRI 809 Delta temperature system MRI 830 Relative humidity sensor All arms used to place gear are 12 feet from the tower face.
Table 6.1.9 shows the specifications which pertain to the orig-l7 inal and current meteorological equipment installed at Grand Gulf. i l8 All data collected since the starting date of about August 1,
- 1972, have met Regulatory Guide 1.23 requirements except the relative humidity data.
Maintenance and operational difficulties were experienced with the relative humidity sensors.
The sensors were
. e'3 replaced by two Tech-Ecology MetSet 5-T Dewpoint Systems in fi December 1976.
v A full-time resident weather equipment technician was assigned to the site from March 1972 through July 1973.
During the second annual cycle, August 1973 through July 1974, the tower and equipment were serviced and maintained by technicians from Vicksburg., The original MRI sensors were replaced in January 1980 with Climatronics and General Eastern equipment.
A breakdown of the sensors at each of the indicated levels is given below:
Surface
- Climatronics 100097 Tipping bucket rain 18 gauge Climatronics 100CR3-2 Delta temperature translator (utilizes 7
33-and 162-foot temperature sensors) 33 feet
- Climatronics 100075 Wind speed sensor l8 100076 Wind direction sensor 100093 Temperature sensor General 1200 MSCM Dew point sensor Eastern
- All parameters are measured by duplicate sensors at each 8
level.
,s iL;)
Amend. 8 12/81 6.1-11
GG ER 162 feet
- Climatronics 100075 Wind speed sensor l8 100076 Wind direction sensor 100093 Temperature sensor
- All parameters are measured by duplicate sensors at each 8
level.
Table 6.1.9 also shows the specifications which pertain to the new meteorological equipment.
7 Meteorological data from the permanent tower will be supplemented with information from the backup meteorological system.
This system will monitor wind speed, wind direction, and sigma theta.
8 The information from the backup system will be supplied to the control room via a telemetry system.
This information will be utilized to ensure data availability should a temporary loss of information from the permanent tower occur.
Table 6.1.9 8
outlines the specifications for the backup meteorological equipment.
All information recorded by the meteorological instruments on the permanent tower are stored both in digital and analog forms.
The analog traces serve as backup to the digital system.
Data from the temporary tower instrumentation were recorded by analog trace only.
The permanent (main) tower serves as a representative observation station (i.e.,
meteorological conditions at that location are considered to be representative of the site).
The river station was installed primarily to measure and record winds in and along the river valley to evaluate the possible meteorological effects of the hills along the eastern shoreline.
The percentage of data recovery during the first annual cycle at the Grand Gulf main meteorological station is given in Table 6.1.10 for the combination of sensor systems used in preparation of joint frequency distributions presented in this report and used in diffusion analyses.
For this combination of sensor systems (162-foot /33-foot AT, 33-foot wind direction and speed),
98.73 percent of all possible sets of hourly values from August 1, 1972 through July 31, 1973 were recovered.
Corresponding data recovery percentages for the second and third annual cycle are shown in Table 6.1.11 and 6.1.12.
During the first two annual data cycles, the meteorological systems were calibrated by protessional meteorologists and technicians employed by Woodward-Envicon/ Woodward-Clyde Consultants.
In the third annual cycle, Grand Gulf plant staff performed the required calibration program with assistance from the consultants.
All calibrations were performed in compliance with Regulatory Guide 1.23.
)
Amend. 8 12/81 6.1-12
GG ER
()
6.1.3.1.1 Meteorological Data Processing The data processing procedure for 3 years of Grand Gulf meteorological data involves three basic steps:
a.
Data collection b.
Data processing c.
Data analysis Seven computer programs have been developed to process the collected data according to steps b and c above.
This section includes a summary of the data collection methods and a description of the applications of the system of programs, a.
Data Collection The onsite meteorological data are recorded in both analog and digital form.
The Analog Data The analog traces are recorded on strip charts which act mainly as a backup and verification for the digital data.
The data are recorded continuously on O'
six chart rolls, one for each of the following sets of l8 parameters:
1.
162-foot wind speed and direction, Sensor A 2.
162-foot wind speed and direction, Sensor B 3.
33-foot wind speed and direction, Sensor A 7
4.
33-foot wind speed and direction, Sensor B 8
5.
33-foot temperature and 162-foot /33-foot AT, surface precipitation, and dew point temperature, Sensor A 6.
33-foot temperature and 162-foot /33-foot AT, surface precipitation, and dew point temperature, Sensor B All wind speeds are recorded in miles per hour.
Wind directions are recorded on a 0-540 degree scale.
Tem--
peratures are recorded in F (degrees Fahrenheit).
The l'
precipitation is a step trace, each step representing 0.01 inch, bV Amend. 8 12/81 6.1-13
GG ER The Digital Data l
The digital data consist of a 15-minute average value derived from 180 samples obtained every 5 seconds
( for every recorded parameter).
This 15-minute 7
average value is recorded on a 9-track, 1600 bit per inch magnetic tape.
Each record on the tape is headed by a date-time identifier (Julian date and minute of the day).
This tape is the source of input for the computer programs.
Data Available to the Control Room The meteorological data are telemetered to the main control room (Bristol telemetry system Model 877231A) and is available to personnel via the balance of plant computer.
Those parameters which are telemetered to the control room are outlined belcw:
1.
Wind speed foot and 162-foot elevations 2.
Wind direction foot and 162-foot elevations 7
3.
Temperature foot elevation 4.
Differential temperature ( AT) foot and 162-foot elevations 5.
Dewpoint foot elevation 6.
Precipitation - ground level b.
Data Processing Currently plans call for the meteorological data to be processed by the Emergency Response Facility Informa-tion System computer.
The original meteorological data (1972-1976) utilized the digital data from the 8
magnetic tapes in processing information.
In order to get the digital data from the magnetic tapes into an acceptable format, the data had to go through three processing phases.
Editing Data The first phase consists of editing the tape for computer compatibility and editing the data for meteorological reasonability.
1.
The first action of the editing phase is to lengthen all records to a standard length of 4507 bytes.
Most records are already this length (75 bytes for each of the 60 one-minute data sequences, and 7 for the date-time identifier).
Amend. 8 12/81
GG ER O
However, there are often several short records due to power failure or equipment malfunction.
Thus a program (EDIT 1) has been developed to lengthen these short records by adding the appropriate number of zeros to the end of the record.
O O
n.
12/81 6.1-13b le
GG ER
/~T taken from farms, preferably 10 to 20 miles northeast of the
(_,/
site.
Gamma isotopic analysis will be performed on edible 2
portions of samples.
6.1.5.2.8 Deer Meat Deer will be sampled annually in the general vicinity of the site in areas where hunting is permitted.
Gamma isotopic analysis will be performed on edible portions of each sample upon collection.
6.1.5.2.9 Fruits and Vegetables Vegetables will be sampled at time of harvest except for green leafy vegetables, which will be sampled monthly when available.
Samples will be collected from the garden nearest the point of greatest D/Q value.
Commercial and private fruit production is rare in the site vicinity.
Wild fruit is present, however.
Wild 2
fruit will be collected, as available, from the site environs, preferably from high D/Q sectors.
Fruit and vegetable background samples will be obtained from an area preferably 10 to 20 miles northeast of the site.
Gamma isotopic analysis will be performed on each sample upon collection.
6.1.5.2.10 Sediment n(')
Shoreline sediment will be sampled semiannually downstream of the plant outfall.
The amount of silt in and the flow of the 1
Mississippi River render midstream sediment sampling impractical.
Gamma isotopic analysis will be performed on each sample.
6.1.5.2.11 Soil One set of soil samples will be taken prior to plant operation.
Samples will be collected at each air sampling location.
Gamma isotopic analyses will be performed on each sample.
l8 6.1.5.3 Data Analysis and Presentation A report will be prepared to present and evaluate preoperational environmental radiological monitoring results.
Data obtained from the preoperational monitoring program will be used along with meterological data to reestimate the possible dose to man from plant operations.
S'titabil,ity of sampling media, locations, and frequency will be reevaluated prior to plant operation.
Changes to the program may be made as indicated by this reevaluation and applicable guides.
6.1.5.3.1 Direct Radiation Gamma radiation survey results will be reported in R/hr.
Direct
[
]
radiation TLD badge results will be reported as a quarterly
\\/
integrated dose in mR along with the average and standard Amend. 8 12/81 6.1-29
GG t:R deviation for all readings.
Quarterly doses at indicator stations will be compared with quarterly doses at background (control) stations.
6.1.5.3.2 Airborne Particulate All results will be reported in pCi/m.
A statistical evaluation 3
will be made of station-to-station and week-to-week variations in gross beta results.
These variations will be evaluated in terms of seasonal fluctuations, influences of worldwide fallout, and other sources.
Gamma isotopic analysis data will be used to identify any radionuclides that may be attributed to reactor operation.
6.1.5.3.3 Airborne Iodine All results will be reported in pCi/1.
If iodine-131 is detected on the charcoal cartridges, the source of the iodine-131 will be evaluated.
6.1.5.3.4 Water All results will be reported in pCi/1.
6.1.5.3.5 Milk 2
Results will be reported in pCi/1.
Indicator stations, if available, will be compared to data from the dairy herd at Alcorn State University.
6.1.5.3.6 Fish and Invertebrates Results will be reported in pCi/kg wet weight.
6.1.5.3.7 Beef (or Goat), Deer Results will be reported in pCi/kg wet weight.
Radionuclides which could be identified with plant operation will be evaluated in terms of the dose to man.
6.1.5.3.8 Sediment and Soil Results will be reported in pCi/kg dry weight and will only be used as indicators of buildup of radioactivity in the environment.
6.1.6 Supplementary Programs 6.1.6.1 Baxter Wilson Impingement Study Systematic sampling of organisms impinged on the traveling screens of the condenser cooling water intake structures of both Units 1 and 2 at MP&L's Baxter Wilson Steam Electric Station was 6.1-30 Amend. 2 11/79
GG ER
(
TABLE 6.1.9 METEOROLOGICAL EQUIPMENT SPECIFICATION AND PERFORMANCE CHARACTERISTICS Temporary Towers (these towers were removed in March 1973) l8 MRI 1071 Mechanical Weather Station Wind Direction Start threshold:
<0.75 mph Accuracy:
14 degree azimuth Delay distance:
50% recovery -
8 ft Wind Run (Speed)
Start threshold:
<0.5 mph Accuracy:
i2%
Respoase distance:
18 ft (63%
rectvery)
Temperature Range:
-30 F to 120 F Accuracy:
13 F (Calibrated to il F)
Permanent Tower (this equipment was replaced in January 1980) l8 MRI 1074-2 Wind Systems Wind Direction Start threshold:
0.75 mph Accuracy:
11%
Delay distance:
4 ft (50%
recovery)
Wind Speed Start threshold:
0.75 mph Accuracy:
-10.4 mph or 1% (which-ever is greater)
Response distance:
18 ft (63%
recovery)
MRI 809 Temperature Temperature Range:
-30 C to +50 C Accuracy:
10.5 C Differential Temperature Range:
15 C Accuracy:
10.1 C Rain Gauge - MRI 302 Tipping Bucket Rain Gauge Accuracy:
11% at 3 in. of rain /hr Picks up each 0.01 in. of rain O~
for each tip of bucket.
Amend. 8 12/81
GG ER (v)
TABLE 6.1.9 (Cont.)
Permanent Tower (Cont.)
MRI 1090-1 Air Bearing Anemometer (wind speed only)
Start threshold:
<0.25 aph Response distance:
Api-Joximately 10 ft at 2 mph Range:
0.25 to 20 mph Accuracy:
0.10 mph or 1% of reading MetSet 5-T Dewpoint Sensor (installed in December 1976)
Range:
-50 C to +50 C Accuracy:
10.5 C New Equipment (this equipment was installed in January 1980) l8 Climatronics System Wind Direction Start threshold:
0.6 mph Accuracy:
13 degrees Delay distance:
0.76 meters
(~'s Dampening ratio:
0.4/3.7 feet
(,)
Range:
0 to 540 degrees Wind Speed Start threshold:
0.6 mph Accuracy:
11% or 0.1 mph Distance constant:
5 ft 7
Range:
0 to 100 mph Temperature Accuracy:
10.2 F Range:
-30 F to 122 F AT Accuracy:
10.1 F or 1% of AT Precipitation Accuracy:
11% up to 3 in./hr Resolution:
0.01 to 15 in.
Dew Point Accuracy:
10.72 F Backup Tower Teledyne Geotech System Wind Direction - Model 1565B Sensor and Model 53.2 Vane 8
Start threshold:
0.7 mph Dampening ratio:
0.4 at 10 degrees f-~s Distance constant:
3.7 feet iL Amend. 8 12/81
GG ER I
TABLE 6.1.9 (Cont.)
Backup Tower (Cont.)
Teledyne Geotech System (Cont.)
Wind Speed - Model 1564B Sensor with Model 170-41 Wind Cups 8
Start threshold:
0.6 mph Turning radius:
3-3/4 inches Distance constant:
1.5 feet Auto Met V Microprocessor O
O Amend. 8 12/81 Sheet 3 of 3 l8 l
__,.,.._,_...._,_,.-.m..m_.-_