Form NRC 218 U.S. NUCLE AR REGULATORY COMMISSION

}

CERTIFICATE OF COMDLIAFCE CFR 71 F1r Radioactive M.terials Pa.zagas Pages N' !' tel 3o:al No. Pag 1.(a) Certificate Nurnber 1.(b) Revision No.

1.(c)

USA /3e Identification No.

1 (d) 1 Pack l..

641/AF 5641 3

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

Tha packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10 Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This cartificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Departrnent of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety ana:ysis report cf the' package design or applicatiort-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

United Nuclear Corporation United Nuclear Corporation Application dated 67 Sandy Desert Road February 2,1968, as supplemented.

l Uncasville, CT 06382 3.(c)

Docket No. 71-5641

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number; Fissile Class, Other Conditions, and

References:

(a)

Packcging (1) MeJel No.: UNC-2500 (2) Description Specific packaging is not required.

Safety of shipment is independent of packaging.

(b)

Contents (1) Type and form of material Unirradiated fuel clusters, modules or other assemblies.

I (2) Maximum quantity of material per package Not to exceed Type A quantities radioactive material and components containing U-235 as specified in Table 1001-I, Revisions 2 and 3 of United Nuclear Corporation applications dated September 14, 1972 and December 2, 1975. The contents of a single shipping container shall be limited to one (1) module or cluster.

8112170461 811201 PDR ADOCK 07105641 l

C PDR

4 Page 2 - Certificate No. 5641 - Revision No. 3 - Docket No. 71-5641 5.

(c)

Fissile Class III (1) For the contents described in 5(b)(1), and limited in 5(b)(2), the maximum number of components per shipment are limited to the following:

Maximum number of components per Item Component shipment

}

1.

Element 40 l

Sub-Assm 9

l, 2.

Element 48 Removable Sub-Assm 20 Sub-Assm 8

l Corner or Cluster Module 4

l Cluster 2

3.

Element 22 Sub-Assm 4

< Type A Module 2

Rodule 1

4.

Element (1) 20

}

Element (2) 22

(

Pre-Assm (2) 6 Sub-Assm (1)(2) 2 Removable Fuel Assm (1)(2) 20 Cluster (1)(2) 1 5.

Element 20 Pre-Assm (Type A, E, F) 4 Sub-Assm (Type D, or Types D + B/C, or 2 B/C) 4 Pre-Assm (Type D or B/C) 6 Cluster i

f 6.

Element 20 Outer Pre-Assm (1)(4)(11) 3 j

Sub-Assm (corner clus) 4 l

Inner Pre-Assm (2)(3)(5)

I (6)(8)(9)(10) 4 Corner Pre-Assm (7) 4 Inner Sub-Assm 4

}

Inner Cluster 1

. -.4.

47 3 -

Page 3 - Certificate No. 5641 - Revision No._3

. Docket No. 71-5641 6.

Alternatively, a maximum of 700 grams U-235 or 40 grams U-235/ inch (not stacked) of the type and form of material specified in 5(b)(1) may compose a' Fissile Class III shipment.

7.

The name plate to which the Model No. is affixed must be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintain its legibility.

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expirat4*a date: March 31,1986.

REFERENCES United Nuclear Corporation application dated February 2,1968.

l Supplements dated:

July 19, August 9, and December 4,1968; October 30, 1969; September 14, 1972; December 2, 1975; and January 12, 1981.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION W$

l Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date DEC 011981 I

4*

U.S. Nuclear Regulatory Commission Transportation Certification Branch Approval Record Model No. UNC-2500 Docket No. 71-5641 By application dated September 9,1981 United Nuclear Corporation requested an amendment to Certificate of Compliance No. 5641 to modify the contents for the Model No. UNC-2500.

The certificate had been revised on August 7, 1981 (Revision No. 2) to delete specified packagings and simplify the contents.

The applicant found the revised contents to be more limiting than the previously approved contents. The certificate has been revised to reflect the previously approved contents.

2Y Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date: DEC 011981 l