F O R M_N R C-$ 91 U.S. NUCLEAR REGUL ATORY COMMISSION

( 3-77)

OFFICE OF INSPECTION AND ENFORCEMENT LNSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT

s. LIC ENSEE
2. R EGION AL OF FSC E Oppt of the Navy U.S. Nuclear Regulatory Commission Mare Island Naval Shipyard 1450 Maria Lane, Suite 210 Vallejo,CA 94592 Walnut Creek, California 94595
3. DOC KET NUM BER{S)
4. LICENSE NUM BE R(5)
5. D ATE OF INSPECTION 04-00364-05 (fy y prf,jcjgj 6 8NSPECTION FONDINGS The inspection was an eramination of the actmties conducted under your license as they relate to radiation sarct) and to compliance with the Commnsion's rules and regulations and the conditions or your license. The inspection consisted of selective esaminations of procedures and repre-sentative records, interviews with personnel, and observations by the inspector. T he rindings as a result of this inspa ron are as follows:

L No items of noncompliance or unsafe conditions were found.

The followmg items of noncomphance related to records, signs, and labels were found:

O A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10 CFR 20.203(b)or 34.42 O

B. Rooms or areas were not properly posted to indicate the presence of a filGli RADIATION AREA.

10 CFR 20.203(c)(1) or 34.42 O

C. Rooms or areas were not properly posted to indicare the presence of an AIRBORNE RADIOACTIVITY AREA.

10 CFR 20.203(d)

O D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE MATERI AL.10 CFR 20.203(c)

O E. Containers were not properly labeled to indicate the presence of RADIOACTIVE MATERIAL.

10 CFR 20.203(f)(1) or (O (2)

O F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not properly posted or made available.10 CFR 20.206(b)

O G. FormNRC 3 was not properly posted.10 CFR 20.206(c)

O 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)

O

1. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)

O L Records of receipt, transfer, disposal, export or inventory oflicensed material were not properly maintained.

10 CFR 30.51,40.61 or 70.51 4 1

..x C

K. Records of leak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c) y t,

O L. Records ofinventories were not maintamed.10 CFR 34.26 C

,s

.p C

M. Utihzation logs were not maintained.10 CFR 34.27 h

Q I

O N. Records of radiation survey instrument calibration were not maintained.10 CFI 34.2d

  • s 0,

_9/s c

s O

O. Records of teletherapy electricalinterlock tests were not maintained as prescribed 15 your licensU Oe O

P. Other

~

^ $1Y

_khPf

(\\RC Inspretor)

7. The NRC Inspector has explained and I understand the items of noncompliance listed above. The items of noncompliance will be corrected within the next 30 days.

9112080393 811117 NMS LIC30

_ 04-00.364-05 PDR (Date)

(l.icensee Representati~e - Title or Position)

ORIGINAL TO LICENSEE 5

_ _ _ _ _ _