Request for Addl Info Re Equipment Environ Qualification Review of Licensees Resolution of Outstanding Issues from NRC Equipment Environ Qualification Safety Evaluation Repts & TMI Action Plan Installed Equipment.
ML20038B227
Person / Time
Site: Surry  Dominion icon.png
Issue date: 11/30/1981
From:
FRANKLIN INSTITUTE
To:
NRC
Shared Package
ML20038B226 List:
References
CON-NRC-03-79-118, RTR-NUREG-0737, TASK-***, TASK-TM IEB-79-01B, RFI-C5257-483, NUDOCS 8112040419
Download: ML20038B227 (13)


Text

-. ._________________________________ ______________________-_________________________________________________

REQUEST FOR AD*!TIONAL INFORMATION IQUIPMENT E!NIRONMENTAL QUALIFICATION (EIQ)

REVIEW OF LICENSEES' RESOLUTION OF OUTSTANDING ISSUES FRCM NRC IQUIPMENT E!NIRONMENTAL QUALIFICATION SAFETY EVALUATION REPORTS (SER) AND TMI ACTION PLAN INSTALLED EQUIPMENT Virginia Electric and Power Company Surry Unit 2 NRC Docket No. 50-281 November 30, 1981 NRC TAC No. 42469 Dmp e o 311zo<f 0 4/ 7 db

.0. Franklin Research Center A Division of The Franklin Institute The Bensman Frerann Parkwey, PMa Pa. 19103 (21S)448 1000

RFI-C5257-483 BACKGROUND Franklin Research Center (FRC) of Philadelphia, Pa. is providing assis-tance to the U.S. Nuclear Regulatory Commission (NRC) for the equipment environmental qualification (EEQ) review of operating reactors. FRC will perform an EEQ review of the Licensee's 90-day response to outstanding issues from the NRC Equipment Environmental Qualification Safety Evaluation Report' (SER) and the installed MI Action Plan equipment. We review will be limited to safety-related equipment potentially exposed to a harsh environment. Se results will be presented in the form of a technical evaluation report for each plant.

mis request for additional information (RFI) is the result of an evaluation of the information provided by letters dated February 1, 1981 (1) and December 1, 1980 (2].* FRC previously requested TMI Action Plan information by a telephone memorandum dated August 12, 1981 (31 Yn response, VEPCO transmitted the following information on September 10, 1981 (4].

a. Comsip-Delphi Engineering Analysis and Test Report 1035-1 on the containment hydrogen analyzers providing IEEE test results.for Model KIII and KIV analyzers
b. Environmental Zone Description Volumes 1-4 for Surry Power Station.

A. FRC REVIEW OF THE LICENSEE'S 90-DAY RESPONSE TO THE NRC EEQ SER Information Recuested Date Received by FRC**

1. In reference to the Licensee's 90-day response (S] to the NRC SER [6) , a legible single copy of each of the following qualification documents is requested in order that the FRC evaluation may proceeds (The numbers in parentheses af ter the letter correspond to the numbers in Section 8 of Reference 5.)
  • Numbers in brackets refer to c_itations found in the list of references.
    • This column will be completed by "3C as the requested information is received.

00h Franklin Research Centee 4osa w w r e w . ,

RFI-C5257-483 Date Received by FRC**

a (2) . Environmental Qualification of Reactor Coolant Temperature Detectors and Containment Pressure Transmitters, VEPCO submittal No.

855, November 1, 1979.

b (3) . Qualification of Resistance Temperature Detectors, VEPCO submittal No. 855A, for North Anna Power Station Units 1 and 2, November 1, 1979. .

c (5) . Learn, J. R., Boston Insulated Wire and Cable Company, to Wright, R. D.,

Stone & Webster Engineering Corpora-tion, 300 V Instrument Cables and 600 V Control Cables, January 17, 1972.

d (6) . Limitorque Corporation, Nuclear Qualification Data for Safety Related Service, NQDS, November 1, 1979.

e (7) . Anderson, T. M., Westinghouse Electric Corporation, to Stolz, J. F.,

Nuclear Regulatory Commission, NS-TMA-1950, September 29, 1978.

Possible attachments include Vota, J. L., Westinghouse Electric Corporation, to Proffitt, W. L.,

Virginia Electric Power Company, October 19, 1978, Eicheldinger, C.,

l Westinghouse Electric Corporation, to Stolz, J. F. , Nuclear Regulatory Commission, March 23, 1977, Westinghouse Sensor Qualification Program, IEEE 323-1971 Demonstration Program, Final Test for Barton/ITT Modified Pressure Transmitter (Proprietary Class 2) .

f (9) . Anderson, T. M., Westinghouse Electric Corporation, to Stolz, J. F.,

Nuclear Regulatory Commission, l

NS-TMA-2120, September 14, 1979, Revis, ion A, September 30, 1979.

, ranklin Research Center A Onnesen af The Freneen m

RFI-C5257-483 Date Received by FRC**

f (9) . Possible attachments include: .

Cont. Westinghouse Supplemental Qualification Testing of Barton Lot 1 Pressure and Differential Pressure Transmitters (Proprietary Class 2) .

g (12) . Chapman, L., Stone, J., Tests of Electric Cables After Simulated Post-Accident Reactor Containment Service, Cerro Wire and Cable Technical Report NP-04, March 1971, h (13) . Alm, C. A. , Mar th J . R. ,

Qualification of Firewall III Class IE Electric Cables, Rockbestos Company, Rockbestos Report 13-10407-E058-13-2, June 22, 1978, Updated August 22, 1978.

i(18). D. G. O'Brien Incorporated,

. Environmental Test Report, DGO Report No. C19QA061, February 28, 1972. .

k (23) . Sheets M. W. , Topical Report on General Electric Vertical Induction Motors, Inside Containment Recirculation Spray Pump Motors -

Surry Power Station - Second Addendum to Cover Heat Aging,.

Radiation Exposure, Vibration, and Steam / Chemical Spray Exposure Qualification Tests, NRC Docket Nos.

50-280 and 50-281, June 12, 1973 and July 23, 1973.

1(24). Sheets, M. W. , Topical Report on General Electric Vertical Induction Motors, Inside Containment Recirculation Spray Pumps for the Surry and North Anna Stations of Virginia Electric and Power Company, Third Addition to Cover Rebuilding Motors Using New Bearings, Docket Nos. 50-280 and 50-281, Report No.

491HA689, July 23, 1979.

00b nklin Research Center A Dhemen af The FraseAn trumhee

RFI-CS257-483 Date Received by FPC**

m (37) . Cerro Wire end Cable Company, Qualification of Firewall III Class IE Electrical Cables, May 1976.

Attachments include: Patterson, W. J.,

Cerro Wire and Cable Company, to Maguire, T. A. , Stone & Webster Engineering Corporation, subject:

Identification.of cable supplied under this P.O. as Firewall III, June 9, 1976.

n (38) . Schwencer , A. , Nuclear Regulatory Commission, to Proffitt, W. L.,

Virginia Electric and Power Company, subject: Environmental Qualification Testing of Continental Instrumentation Cable, July 25, 1979.

o (40) . Lasky, J. S. , Okonite Company, to Bonner, J., Stone & Webster Engineering Corporation, October 15, 1980.

p(42). Ling, T. H., Anaconda Wire and Cable Company, to Bonner , J. , Stone &

Webster Engineering Corporation, October 28, 1980.

q(44). Bell, C. E., General Electric Company, to Bonner, J., Stone & Webster Engineering Corporation, subject:

Qualification of Inside Recirculation l

Pump Motors to Withstand a pH of 7-11, October 28, 1980.

r (4 5) . Drab, J. B., Limitorque Corporation, to Reilly, P., Stone & Webster Engineering Corporation, subject:

Qualification Information for Limitorque Actuators - Surry Power i

Station Units 1 & 2, October' 8,1980.

Possible attachments include: Reilly, l P., Stone & Webster Engineering Corporation, to Drab, J. B.,

Limitorque Corporation, two letters, i

September 11, 1980 and September 29, 1980, MacFarlane, I. S., Stone &

Webster Engineering Corporation, Memo I

nklin Research-- Ce.nter I

RFI-C5257-483 Date Received by FRC**

r (45) . to Whom It May Concern, dated Cont. January 28, 1981, MacFarlane, I. S. ,

Stone & Webster Engineering Corpora-tion, to Drab, J. B., Limitorque Corporation, Telephone Memorandum dated December 12, 1980, MacFarlane, I. S., Stone & Webster Engineering Corporation, to McQuillan, P.,

Limitorque Corporation, Telephone Memorandum dated October 27, 1980, Zarandi, VEPCO, to MacFarlane, I._S.,

Stone & Webster Engineering Corpora-tion, November 7, 1980; MacFarlane, I. S. , Stone & Webster Engineering Corporation, to Padulla, D. and Smith, F., VEPCO, Memo dated November 3, 1980, MacFarlane, I. S., Stone &

Webster Engineering Corporation, to Padulla, D., VEPCO, Memo dated November 4, 1980.

s (47) . Conax Corporation, Engineering Department Certificate to Virginia Electric and Power Company, subject:

Compliance of NAS-21 revised May 5, 1972 to equipment ordered under purchase order SN-491, dated December 13, 1972.

t (51) . Drab, J. B. , Limitorque Corporation, to Barnhart, J. H., Stone & Webster Engineering Corporation, subject:

Qualification Information for Limitorque Actuators - Surry Power Station Units 1 & 2, two letters, November 13, 1980. Possible attachments include: Barnhart, J. H.,

Stone & Webster Engineering Corporation, to Limitorque Corporation, November 3, 1980.

u (52) . Drab, J. B., Limitorque Corporation, to MacFarlane, I. S., Stone & Webster Engineering Corporation, subject:

Qualification Information for Limitorque Actuators - Surry Power Station Units 1 & 2, November 14, 1980. Possible attachments includes l

y . t 4u00u

.nwiin er n earch cons., ,

A DMuen of The Frannen insEhme

RFI-C5257-483 Date Received by FRC**

u (52) . MacFarlane, I. S., Stone & Webster Cont. Engineering Corporation, to Drab, J.

B., Limitorque Corporation, Memo -

Subject:

79-OlB Environmental Qualification of Equipment, dated November 12, 1980, MacFarlane, I.

S., Stone & Webster Engineering Corporation, To Whom It May Concern, Memo dated January 28, 1981; MacFarlane, I. S. , Stone & Webster Engineering Corpcration, to Drab, J.

B., Limitorque Corporation, Telephone Memorandum dated December 12, 1980.

i v(53). Kuster , J. M. , Raychem Corporation, to Barnhart, J. H., Stone & Webster Engineering Corporation, subject:

i Flamtrol Wire & Cable, North Anna i

Nuclear Units 3 & 4, Stone E. Webster

' P.O. 3190, November 17, 1980.

Possible attachments include:

MacFarlane, I. S., Stone & Webster Engineering Corporation, to Kuster, -

J., Raychem Corporation, Telephone Memorandum dated November 18, 1980.

i w (54) . Lewicki, R. G., Reliance Electric

Company, to Barnhart, J. H. , Stone &

l Webster Engineering Corporation, j subject: VEPCO/Surry Power Station Units 1 & 2, Motor Bearing I Lubricant, Reliance Part No.

4824-15-A, November 14, 1980.

x (55) . Reliance Electric Company, Nuclear Power Motor Systems, Type Test Support Analysis, Random Wound Motors, Summary Report NUC-9, July 1, 1978. Includes Appendix:

Seismic Report 78-R-33, Justifica-tion for Omission of Routine "End Turn Stress Analsyis" for Random Wound Motors, July.10, 1978.

y(56). Electric Power Research Institute, Evaluation and Test of Improved I

__nklin Research._. Center

~

P I _... _ ~ . . ,___y , , , . - _ , , _ . _ _ _ . . _ - . . _ . - , , - . _ _ . _ _ . _ _ _ _ _

RFI-C5257-483 Date Received by FRC**

y (56) . Fire-Resistant Fluid Lubricants for Cont. Water Reactor Coolant Pump Motors, Volume la Fluid Evaluation, Bearing Model Tests, Motor Tests, and Fire Test, Interim Report NP-1447, July 1980.

z (58) . Kuster, J., Raychem Corporation, to MacFarlane, I. S., Stone & Webster Engineering Corporation, subject:

IE Bulletin 79-OlB, Environmental Qualification of Equipment, Surry Power Station Units 1 & 2, Additional Qualification of Raychem Flamtrol Wire and Cable, Spec. No.

NAS-3190, December 2, 1980.

aa (60) . McGowan, E. J., Raychem Corporation, Raychem-Flamtrol, Continuation of LOCA Simulation Test, Test Report EM

$1403, December 9, 1977. Possible attachments include: Kuster, J.,

Raychem Corporation, to MacFarlane, I. S., Stone & Webster Engineering ,

corporation, January 27, 1981.

bb (61) . Cardello, P. S., Anaconda Ericsson l

Incorporated, to Bonner, J., Stone &

Webster Engineering Corporation, subject: VEPCO Surry Qualification Data, three letters, October 8, 1980, October 21, 1980, and December 10, 1980.

l cc (64) . Lasky, J. S. , The Okonite Company, i to. Barnhart, J. H., Stone & Webster Engineering Corporation, subject:

l Environmental Qualification of l Equipment, Surry Power Station Units 1& 2, December 17, 1980.

l dd (68 ) . Lasky, J. S. , The Okonite Company,

( to Barnhart, J. H., Stone & Webster l

Engineering Corporation,

Reference:

J. O. No. 12846.44, December 22, 1980. Possible attachments include: Barnhart, J. H., Stone &

l

! nklin Research Center

RFI-C5257-483 i

Date Received by FRC**

dd (68) . Webster Engineering Corporation, to Cont. Lasky, J. S. , Okonite Company, December 17, 1980; MacFarlane, I. S.,

Stone & Webster Engineering Corporation, To Whom It May Concern, Memo dated February 3,1981.

ee (69 ) . Tolerico, F. A., Westinghouse Electric Corporation, to Barnhart, J. H., Stone & Webster Engineering Corporation, subject: Surry Power Station 1 & 2, Environmental Qualification of Hydrogen Recombiner, December 8,1980.

ff (72) . Cookinham, J. H., Westinghouse Electric Corporation, to Brown, S. C.,

Virginia Electric and Power Company, subjects North Anna Power Station, NUREG-0588 Equipment Qualification, October 30, 1980. Possible attachments include: Newcomb, R. C.,

Virginia Electric and Power Company, to MacFarlane, I. S. , Stone & Webster ,

Engineering Corporation, Memo dated December 31, 1980.

9g(73). Drab, J. B., Limitorque Corporation, to Reilly, P. , Stone s Webster Engineering Corporation, subject:

Qualification Information, North Anna Power Station Unit 2, 0 ptember 19, 1980. Possible attachmints include:

MacFarlane, I. S., Stone & Webster Engineering Corporation, To Whom It May Concern, Memo dated January 28, 1981, MacFarlane, I. S., Stone &

Webster Engineering Corporation, to Drab, J. B., Limitorque Corporation, Telephone Memorandum dated December 12, 1980.

th (76) . Conax Corporation, Design Qualifica-tion Test Report for a Conax Low Voltage Control Service Classifica-tion Conductor Feedthrough Assembly P/N 7641-21001, Test Report No.

IPS-353.2, June 18, 1979.

(Proprietary) nklin Research Center

^

RFI-C5257-483 Date Received by FRC**

11(77). Federick, W. C., Conax Corporation, to Reilly, P. , Stone & Webster Engineering Corporation, subjects

  • Environmental Qualification, Electrical Penetrations, North Anna Units 1 & 2, January 8, 1981.

jj (79) . Kushner, J. R. , Rockbestos Company, to Barnhart, J. H., Stone & Webster Engineering Corporation, subject:

S & W letter of 12/12/80, Items 1.a. (1) and 1.a. (2) , February 24',

1981.

kk (80) . Ling, T. H., Anaconda Ericsson, to MacFarlane, I. S., Stone & Webster Engineering Corporation, subject:

600-Volt Power Cable, February 23, 1981.

11 (82). Pirrong, J. S., Boston Insulated Wire & Cable Co. , to Petty, - K. ,

Stone & Webster Engineering '.

Corporation, subject: North Anna Cables, F.O. NA-265/1265, April 30, 1981.

1 mm (83 ) . Drab, J., Limitorque Corporation, to

[

Barnhart, J. H., Stone & Webster Engineering Corporation, Telex, May 18, 1981.

l nn (84 ) . Diab, J. B., Limitorque Corporat' ion, to Barnhart, J. H., Stone & Webster Engineering Corporation, subject:

Qualification Information for Surry Power Station - Units 1 & 2, May 19, 1981.

oo (85) . Technical Report 123-1247 Rev. A dated April 1978.

i pp(86). Technical Report 123-204 Rev. A dated March 25, 1975.

qq (87 ) . Report No. 23-1268 Revs. dated February 26, 1975. ,

_nklin Rese_ arch _C' enter

RFI-CS257-483 Date Received by FRC**

rr (88) . Report No. 123-1269 F.sv. dated February 26, 1975.

ss (89) . Amphenol Design Verification Testing (DVT) Report No. 12.~ .275.

tt (90) . Qualification Report of General Electric Vertical Induction Motors for Class lE Outside Recirculation Spray Pumps.

uu (91) . Siemens-Allis Inc. (Medium Motor Division) Equipment Qualification Random Wound Motors for Class IE Safety Related Service.

vv (93 ) . Letter dated August 1,1969 from Robert H. Dubuc of Cerro Wire &

Cable Company to Mr. Roger Clark of S&W.

ww (94 ) . Cerro Wire & Cable Company Specification No. RSS-3-701 Issue 4, November 1, 1968 on Pyro-TROL III, 600 Volt Control Cables.

xx (96) . NUS-VEPCO QDR Package 5437-96-01.

yy (98 ) . NUS-VEPCO QDR Package 5437-SOV-02.

zz (100 ) . NUS-VEPCO QDR Package 5437-122-01.

aaa (102) . NUS-VEPCO QDR Package 5437-121-01.

bbb (104 ) . NUS-VEPCO QDR Package 5437-124-01.

ecc (106) . NUS-VEPCO QDR Package 5437-119-01.

ddd (108 ) . NUS-VEPCO CDR Package 5437-125-01.

eee (110) . NUS-VEPCO QDR Package 5437-118-01.

fff(ll2). NUS-VEPCO QDR Package 5437-123-01.

ggg (114 ) . NUS-VEPCO QDR Package 5437-123-02.

hhh (ll6) . NUS-VEPCO QDR Package 5437-125A-01.

Ub Franidin Research Center -

A c>a a w m re m

, ius-C5127-483 Date Received by FRC**

+

111(118). NUS-VEPCO QDR Package 5437-117-01.

g, syj ~

  • jjj (120) . NUS-VEPCO QDR Package 5437-127-01.

kkk (122) . NUS-VEPCO QDR Package 5437-104-01.

111(124). NUS-VEPCO QDR Package 5437-MOV-2-01.

nnn (126) . NUS-VEPCO QDR Package 5437-MOV-2-02.

oco (127) . NUS-VEPCO CDR Package 5437-133-01.

ppp (128 ) . Automatic Dampers (Safety Related)

Qualification Report for Electric Actuators by RCS.

qqq (134 ) . NUS-VEPCO QDR Package 5437-124-02.

err (135) . NUS-VEPCO QDR Package 5437-128-01.

sss (136) . NUS-VEPCO QDR Package 5437-103-15.

ttt (137 ) . NUS-VEPCO QDR Package 5437-132-01.

uuu (138) . NUS-VEPCO QDR Package 5437-120-01.

vvv (139 ) . NUS-VEPCO QDR Package 5437-130-01.

www (140 ) . NUS-VEPCO QDR Package 5437-103-02.

yyy)l41). NUS-VEPCO QDR Package 5437-105-01.

xxx (142) . NUS-VEPCO QDR Package 5437-69-01.

t l Mr. Cyril J. Crane i

Franklin Research Center The Parkway at Twentieth Street Philadelphia, PA 19103 Telephone No. 215/448-1353 l Telecopy No. 215/448-1296 Telecopy Confirmation No. 215/448-1215 l

l s -

' ~

d.

nkHn Rese

~ ~_ arch. Center.

i A

RFI-CS257-483 rs REFERENCES

1. Surry Unit 1 - IE Bulletin 79-01B, W I Review - Supplement 3, Revision 3 Change Package Virginia Electric & Power Co.,

01-Feb-81

2. VEPCO Surry Unit 1 - IE Bulletin 79-013 Revision 2 - Supplement 3 M I Review Virginia Electric & Power Co. ,

01-Dec-80

3. Telephone Memorandum dated 8/12/81 C. J. Crane, J. Murphy (FRC) with D. Nabors (NRC-P.M.) ,

R. Newcomb and J. E. Wromiewicz (VEPCO) .

Subject:

RFI for Surry Units 1 and 2

4. R. H. Leasburg Letter to H. R. Denton and S. A. Varga (NRC) '

Subject IE Bulletin 79-01B Supplement 3 DtI Peview, Surry Power Station '

Unit Nos. 1 and 2 September 10, 1981

5. R. H. Leasburg -

Letter to H. R. Denton and S. A. Varga (NRC) ,

Subject:

Response to Safety Evaluation Report for Environmental Qualification ... IE Bulletin 79-OlB 90-Day Peview; Surry Units 1 and 2, Virginia Electric & Power Co.,

24-Aug-81 Serial No. 329

6. Office of Nuclear Reactor Regulation

( Safety Evaluation Report for Surry Unit 1 l Environmental Qualification of Safety-Related Electrical Equipment l

l USNRC, 21-May-81 l 7. NUREG-0737, " Clarification of TMI Action Plan Requirements" l NRC, November 1980 e e

  • eED g ,

6 nklin Research Center A Ohemen of The Fearmen human

~ '

i .

-- t

, , _ , , . _ _ _ _ -