ML20038A949

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Crosby SRV Solenoid Valve, Initially Reported 810916.Correction of Collet/Yoke Spacing Provides Acceptable Value for Startup.Alternative Permanent Solutions Being Pursued.Next Rept by 811215
ML20038A949
Person / Time
Site: LaSalle  
Issue date: 11/19/1981
From: Sargent C
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8111240496
Download: ML20038A949 (2)


Text

.-

O )s Commonweanh Edison C"

[

one First National Plaza Chicago, Ill nois

~

u8 Aadress Reply to: Post Office Box 767 j

Chicago, Illinois 60690 Novembe r 19, 1981

'shkY'lty Mr. James G. Keppler, Director

$y{'.f{f[]'

P f

Directorate o f Inspection and g,

Enforcement - Region III U.S. Nuclear Regulatory Commission t'

NOV2 319816-799 Roosevelt Road va.mcum maeon Glen Ellyn, IL 60137 g

i s

w h'#'\\

Subject:

LaSalle County Station Units 1 and 2 i

's Crosby SRV Solenoid Valves 10 CFR 50.55(e) Interim Report #81-06 NRC Docket Nos. 50-373 and 50-374 Reference (a):

E. D. Swartz letter to J. G.

Keppler dated September 16, 1981.

Dear Mr. Keppler:

The purpose of this letter is to provide an updated status of the Crosby SRV Solenoid Valve 10 CFR 50.55(e) report as committed to in Reference (a).

The testing with the modified collet / yokes resulted in a high number of coil failures.

Investigation of these failures determined the collet / yoke spacing to be improper.

Retesting with different spacing was completed November 16, 1981, with no coil failures.

No other test results are presently available.

Parallel path resolution of the problem is being pursued.

These alternate solutions are:

adaption of the Dickers SRV Solenoid to the Crosby Mounting and Crosby's working to provide a qualified solenoid.

The collet / yoke replacement is considered to be a near term solution to provide an acceptable valve for LaSalle Unit start-up.

The other solutions are considered to be more permanent.

If one of them proves to be acceptable and available before start-up, they will be used in place of the collet / yoke assembly.

  1. 0V

$A3$o$Do5000 2 0 1981

[ <'

~

1 A follow-up report will be provided by December 15, 1981, to outline the longer term program and provide a status for LaSalle Unit 1.

If there are any questions in this regard, please contact this office.