Application for Proposed Change 86,Suppl 2 to License DPR-36,revising Acceptance Criteria Used to Determine That ECCS Valve Barriers Are Intact.Suppl Supersedes Proposed Changes Submitted 810603 & 30
ML20037D361
Person / Time
Site: Maine Yankee
Issue date: 07/06/1981
From: Monty C
Maine Yankee
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20037D362 List:
References
FMY-81-100, NUDOCS 8107100126
Download: ML20037D361 (3)


Text

-

Pro o ed Chg tb. 86 - Supplement 2 MAME '*%j#A/1#EE 4 Tam /cPali/ERCOMP409*

AUGUSTA 1A E TE E

(207) 623-3521 g3* Q[f

____.e49 July 6, 1981 s

?.

FMY 81-100 cy

' Y' (M c

/'

c

~m 2

yfIo

$ I7-2l g Q 'h id O 5 United States ibclear Regulatory Commission C

Washington, D. C.

20555 C

a -

t-7 : /

Attention: Office of tbclear Reactor Regulation g

y

/

Q

Reference:

(a) License ib. DPR-36 (Docket tb. 50-309)

! Ab (b) Letter from MYAPC to USNRC dated March 9,1981 (FMY 81-37)

(c) Letter from USNRC to MYAFC dated April 20, 1981, Confirmatory Order (d) Letter from MYAPC to USNRC dated June 3,1981 (Proposed Change ib. 86) (FMY 81-86)

(e) Letter from MYAPC to USNRC dated June 30, 1981 (Proposed Change No. 86, Supplement 1) (FMY-81-94)

Subject:

Modifications to Maine Yankee Technical Specifications Concerning LWR Primary Coolant System Pressure Isolation Valve Surveillance

Dear Sir:

Pursuant to Section 50.59 of the Commit,sion's Rules and Regulations, Maine Yankee Atomic Power Company hereby proposes the following modifications ',

Appendix A of the Operating License.

PROPOSED CHANGE Reference is made to the Technical Specifications contained in Appendix A to Operating License tb. OPR-36 issued to 4aine Yankee Atomic Power Company for the Maine Yankee plant. We propose to nodify current Technical Specifications as #ollows:

Replace pages 4.6-1 through 4.6-4 of Specification 4.6 with the attached revised pages 4.6-1 through 4.6-5.

Replace page 3.19-1 of Specification 3.19 with the attached revised pages 3.19-1 arid 3.19-2.

O/

3 REASON FOR CHANGE This proposed change is submitted as a supplement to References (d) and (e) as

/

I a result of informal discussions with the NRC staff.

This supplement includes a revision to the acceptance criteria usec to determine that the ECCS check valve barriers are intact and a conditional exception to monthly testing of the LPSI Motor Operated Valves.

This supplement supercedes the proposed i

I channe submitted via References (d) and (e).

l 8107100126 810706 l

PDR ADOCK 05000309 L_p PDR

M AINE YANKEE ATOMIC POWER COMPANY United States Nucir;c Regulatory Commission Page Two Attn: Offi.'e of i clear Reactor Regulatien July 6, 1981 The Reactor Safety Study (WASH 1400) identified an interfacing system LOCA (Event V) as a risk which warranted consideration.

In Reference (c) the NRC indicated they had determined that an event V configuration existed in the Maine Yankee design.

in Reference (b) Maine Yankee committed to installing an additional low pressure safety injection check valve between the existing LPSI check valves during the 1981 refueling outage.

That change has eliminated the event V configuration from the Maine Yankee design.

In addition, in Reference (b) Maine Yankee committed to periodic surveillance of the LPSI check valves to ensure that two barriers were intact.

This commitment was included in the confirmatory order Reference (c) which requires Maine Yankee to develop and obtain approval for technical specifications eelating to LPSI check valve surveillance.

This proposed change is necessary to meet the requirements of the order.

SAFETY CONSIDERATIONS This change is submitted in order to fulfill Maine Yankee's commitmen' Reference (b) and is not considered to constitute an unreviewed safr question. This change has been reviewed by the Plant Operating Review Committee and Nuclear Safety Audit Review Committee.

FEE DETERMINATION This proposed change requires an approval that involves a single safety issue and is deemed not to involve a significant hazard consideration. For these reasons, Maine Yankee Atomic Power Company proposes this change as a Class III Amendment. A pr yment of $4,000.00 was submitted w3 th Reference (d).

SCWDULE OF CHANGE In Reference (c), the NRC issued an order requiring Maine Yankee to obtain approval for this proposed change prior to returning to power following spring 1981 Cycle 6 refueling. Maine Yankee is scheduled to return to power on July 9, 1981.

It is, therefore, important for the USNRC to expedite its review and approval of this proposed change in order to eliminate any unnecessary down time. The changes described in this proposed change will be incorporated into the Maine Yankee Technical Specifications upon receipt of your approval.

OTHER (1)NSIDERATIONS Maine Yankee Technical Specification Proposed Change No. 80, affecting Specification 3.19, is currently awaiting approval. Additionally, Amendment Na. 56 to the Maine Yankee Technical Specifications provided temporary relief from one aspect of Specification 3.19.

The time period during which this temporary relief was applicable has passed and, therefore, there is no further need for Amendment No. 56. Since both of the above actions affect Specification 3.19, in addition to the change being requested herein, we have taken the liberty of attaching an alternative Specification 3.19 which includes the effects of all tt.ree of the aforementioned actions.

m_

MAINE YANKEE ATOMIC POWER COMPANY thited States f4Jclear Regulatory Commission Page Three Attn: Office of PAJclear Reactor Regulation July 6,1981 We trust this information is acceptable; however, should you required additional information, please feel free to contact us.

Very truly yours, MAItE YAtKEE ATOMIC POWER COMPANY dyb Charles E. Monty Vice President Production and Administration i

STATE OF MAINE

)

)ss COUNTY OF KENNEBEC)

Then personally appeared before me, Charles E. Monty, who, being duly sworn, did state that he is a Vice President of Maine Yankee Atomic Power Company, that he is duly authorized to execute and file the foregoing request in the name and on the behalf of Maine Yankee Atomic Power Company, and that the statements therein are true to the best of his knowledge and belief.