Requests Approval to Use ASME Code Cases N-302,N-309 & N-310.Util Has Not Been Notified Re 810123 Request for Authorization to Use ASME Code Case N-298
ML20037D001
Person / Time
Site: Marble Hill
Issue date: 04/16/1981
From: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8104280286
Download: ML20037D001 (2)


Text

.. -

M a,. o

[

7\\

Q % 'g, CISsf T}

PUBLIC SERVICE h

[!

INDIANA t

3 APrtl 16, 1981

' 'q g ',3,

/

S. W. Shields Senior Vice Presdent -

Nuclear Division Mr. Harold Denton, Director Docket Nos.: STN 50-546 Office of Nuclear Reactor Regulation STN 50-547 U.S. Nuclear Regulatory Commission Construction Permit Nos.:

Washington, D.C.

20555 CPPR-170 CPPR-171 MARBLE HILL NUCLEAR GENERATING STATION UNITS 1 AND 2

Dear Mr. Denton:

By this letter, Public Service Company of Indiana, Inc. (PSI) requests your approval for use of the following ASME Code Cases that are not included in either Regulatory Guide 1.84 or 1.85:

Code Case N-302 fa u.a Mng NX-4231.1 Section 111, Division 1 Construction Code Case N-309 Documentation of Material for Component SupportsSection III, Division 1 i

l Code Case N-310 Certification of Bolting Materials l

l Additionally, by a letter dated Januaqr 23, 1981, PSI requested your approval for use of ASME Code Case N-298.

This Code Case provides that magnetic particle or liquid penetrant examination as spe:ified in NF-5111 may be used in lieu of visual examination required by NF-5200 for Class 1, 2, 3 and MC component supports. To date, PSI has not been notified of the NRC approval for use of this Code Case.

goel, si o

h P. O. Box 190. New Wasnington, Indiana 47162 I

812. 289.1000 m o m o $k

a, e

Mr. Harold Denton, Director April 16, 1981 Your prompt review and response to the above items is requested. Should you have any questions regarding these matters please cor. tact me at your convenience.

Sincerely,

//

GAS /kdt S. W. Shields cc: V. Stello, Jr.

J.G. Keppler E.R. Schweibinz, P.E.

J.J. Harrison