l l
J' 4 i
',,,, y c,,,
u.s. AToutc ENEncY COMMiLSION 1
l
+ Hir's:
v' i
],,'
Mc#N[jg CcRTIFICATE OF COMPLIANCE For Hat.oaci..e Maier.ais Pad ages l
la Cestif.cate Number.
Its, Havisen No.
1 9033 3 Sc Facaage lovnt f. cation No
- 2. PRE AMitLE USA /9033/8 Id. Page No.
le. Total No. P 0
1 3
I i
22 Th.s cete.f.cate is issu 4 to sansly Sect.ons Mates.a s Hegasatens (49 CF H 170-109 and 14 CF R 303* a o Sections 11.1333a,172 334, U3 395 e De:wrtme-t of tramportation Haterdous Dani,erous Carr,oes Hegulations (4ti CF R 146-143), as amenced.146-19-104 and 14619 10a of the Deparlment of Transpo* tat.c.
2b.
Reguiat.cas, Part 71,**fackapng of Had,oactia Materian lor Transpo itle 10 Code of Federal Cond.t.ons **
.oactive Material Under Cer:ain
?
\\
2c, Transportarian or other appi. cable segutatary agencies, anclud.
N will be transporled.
or into which the pa:kage u,
- 3. Th.s certificate is issued ori tne bass of a safety analysis report of ahe pack,2e des gri or appbeation.
(1) Prepared by (Name arV eddreult
- 42) Title and identification of report or apphcat.on:
Technical Operations, Inc.
Radiation Products Division Technical Operations, Inc. application Northwest Industrial Park.
dated November 8, 1974 j
Burlington,11assachusetts 01803 (3)DocketNo 71-9033
- 4. COND:TioNs This ceriilicate is cona tional own the fuiteit.ng of the requiremenis of Sutmar D of 10 CFH 71 as app en item 5 below.
e cond,tions specifeed g
- 5. Description of Packageng and Author.4ed Contents, Model Number, F ssite Class. Other Cond.tsons and H i
erences:
(a) Packaging 1
(1) flodel nurr.bers:
Model 660, !!adel 660E (2) Description k
A ste'el encased, uranium shiellie' Gamma' Ray Projector.
1 d
1 Primary material, uranium shield, zircalloy "S" tube, and end plugs. components consist of an out j
j contents are securely positioned in the zircalloy "S" tube by a The i
source cable locking device and shipping plug. Tamper-proof seals L
are provided on the packaging.
Total weight of tie packaging is 44 pounds.
l g
't 0
F i
i C1 I
i
@(;\\q()*
Q l
,1 i
j i
'N
\\
' ;, f. d Page 3 - Certificate fio. 9033 - Revision flo. 0 - Docket tio.
71-9033 O
t, REFERErlCES I
Technical Operations, Inc. application da t ed floveinber 8,1974, requesting approval to deliver special fona Iriditun 192 sources in
,j Models flos. 660 and 660E Gamma Ray Projectors to a carrier for I
transport.
FOR TiiE ti.S. AICMIC Ef?ERGY C0FellSSIOli k
d<cmd, I 4%< b=d Charles E. flacDonald, Chie i
Transporta tion Brancti Directorate of Licensing l
1 Date _Dt?Cember 16, 1974 i
,S gj I
t 6
0 1
I I
i 6
,J' f,
)
4'0335 o