May 23,1977

(

Dcchet ;.as. 50-2*

W-il

D. 3.,.r and Hr. Louis J. Sirico, Jr.

Pualic Interes: Re:carch Croup 1032 M Street, W., Suite 101 Vashington, D.C.

20036

Dear !*r. Strice:

This letter is in further response to your June 11,197G rewest wich cetitioned for Issuance of en Order to Sho.s Cause pursuant to 10 C. "

s 2.M5 on behalf of the hest Er. gland Coalition on iluclear Pollut;an one.

Safo Pov:er for licine.

You re.iuested that.n Order to She..' Cause be

=

served on the licensees of the Yantee 0.ovie, Ycrc ont Yankee, and U.a.ine Ycn!'ee pc'fer plants to sus ~?nd their opera.tino licentes for allccce F

[.

deficier.cies related to the quality assurance (OA) proper s for the:2 nlants.

Previously, in our letter to you 60tec June Su,197b, e cckwileJ.m receipt of your natition and said ue uculc. tC e tim nr rn; riz e actv.rs ce,4 a : vise yea cf cur cecision cr. vcor reaurst.

.: a mttr r c' clrrification, suring rur on r tino lici-n<;^ c vic.w.

f: r j'

t'w ;;- 16:: Ynns.e.nJ VerPcnt Y4M.de &cilities,

'O 173 IC. 1 ".^ f. '

I r r.~ " r.r-f a r *,. 0 f feCililler. to cC der I'.

tbt r*

Cr1 L ric.,: ;3 ' ;i s I

'e1? it.

ib li CE: P:r: 6 l.

el ti Gri: YW t e-f..m t I 1 C C.+T o

.' frP"r0

' J:5 'l!"

,,tenniX ~

.l0 S iC.UJ7d, '. 52.

1 %) t~.11 vfcr1

.-.. y s. i m a _w,..s... :.w r,

"a '..>'..~. >

  • h '- "i

.a

~- ' ' '. '. ' ' ' _ 't.'. ~ l 's ' l ~.,

.'c-i.. c.. j n.3) r.

i i

n.

were licen1Cd F::r6 Sp'CifiC al.G I:';'rOYOi Mib7DC. CS D el u.'9 3 M to t.ou tr> satisfy tS: Oa criteri; in Twen:ix f..

At tse tir.c vs.- receival 1 UP rd i.1 the STOCCS! cf POVidrin[ thO YTin'.';0 Ato iC y0er 1-UtitioD, Clectric Cc;.;any (YACC) CA troire< for ' c purpose of oc.utin; t"e YAEC M r.rogrm cescription. As nart of 1. tis cea.tinuine revic.! process r.no in resp;nse to cur rcquests YAEC su!'ritted its inpical Eemart YN'I.P-1, "f?erational 0 ;rlity 3. surar.ce,' r..ateit.%,te ter 1,177C. On Dece% cr 2, 15 7'i, ane.lo nuary 13, 1977, YliC subnitted were: c.:st.r.

I an 7 :nc ent l

8o. 2 tc the rem et.

Y'TC 's tonical re,v rv. en.' ti>e. e ' c ts collectivrdy previca t% u! 9-ice '.'A procrn cescriptio- (c0nsolinuter :n Topical

~~..'.'i''l.

s.'*i " I.'si D '.

,.. m.A r '

V, ', #

  • I I. - T. t'iit't ' d,.'.F I.,l 0 7 7 I,
0. ". C. '. '

4..

o s

ir:VGlVIh#4 C?fOt.'/ rela [M EtIUCtuIes, I[sI2'E III CCONn$ ^* 0

/'

Yani:re-love, ie rcont' Yankre, and Wine Ycni.ee f acilitias.

/

..,w 8 4 * " * ** E P b AYI 5*

.....m.

l

'

  • O ' T4 4 3 L' v. s s o, c e u s % r... v.% s onec ts s e r..p r..

.ii=is!9

es G

z =i:

r. !:i n c.'

?-

May 23, 1977

==

===,

.UU".

. :=

..c Law riaitmort tu AA prcgrer decribed in report Wie. nnd 12 Nuc concluced I:at this prcgram contains recuirewnts and contrain d

. ricn, A en uroperly f r plc!:!cnted, ceply eith tb; renoirewnts of 28 h pandi:4 it to Part 50 and h:SI stam!arr!s contained in Section 17.2,

=E===E

%cliQ> t.sserance during tne Operations-Phase," cf the imC Stenderd E"?!f.

Revie:I Plen G.:L*EG-75/057).

=Q Ii. suc. cry, ut have concluded that the QA progrca ccscribed in report

- 22; YTJi+-1-A costs the current tSC recnirements nnd is acceptable for

=M the ocerations phase of Yankee-Reec, Ver.ient Yankee, and Mainc Yanhec.

4:V5 Proper impler.entation of the approved Q/. progran v.111 be verified

~~

ny ;dC's Office of Inspection and Enforcer.:ent thrcuch periodic

5=

inspections at esch facility.

j

.;~

Ly 1ctter Cated thy 4,1977, the '.AEC incorperated report YGOAP-1-A 5...1.

by reference into the dockets for Yankee-Roue Ver.mont Yanhoe and Esse i aine Yankee, Occket ilo. 50-29, 50-271, and 50-309 respectively.

In E Ei thet lettor YAEC Elso requested L'RC epproval for inpleac1tation of the st:ff eccepted CA progran at these facilitics not latcr than 90

=?

days fro: the date of approval. By letter dated '*cy 17,1977, PC

.jj cyprenc-d the license 's request.

~ ~ ~ -

Lince Y! C new h w sn approved updated Ofa progr m descriptica 't.ich

=

mcts rc':ulatory recuireRent: 9a t.clicvc that the cemem tWs you 1

order

=rd

. raitor rr:ve be n resolved and tnat there is no bc::is for a to Ir.m. Ccuse or for ' fortice 4ction on tM in":es rcirec Sy yr,ur

- - =

pg.

3,

..u.

';im rol /,

c:WM Widl 2

t.h.Cus /

J Edcon G. Caso, f.cting Director R

Cffice of 1:uclear Reactor Rcenlation

Ncicsurss:

DISTRIBUTION 1.-

'RC letter to Y.".EC octed Dockets (50-29/271/309)

NRC(3)

KRGoler 0 ELD

g,r-il 4,1977 2.

Y.$.EC letter dated ::av 4, LOCAL PDR(3)

ASchwencer 0!&E (3)

E..,

1977 ORB #1 Reading ABurger ACRS (16) sa

~

2.

MC letur to YAEC datad ORB #4 Reading SMSheppard DEisenhut 1977 NRR Reading RReid DJSkovholt

=

.?v p,R:0RB#4 - D0h0RB#4 EDO Reading L01shan JRBuchanan

"=

O DO 1 i

RR'ei d' 4

1shan JS#igel EGCase JSeigel eT q;k.

$[BAbernathy

?

5//gf77 5/l3/77 5/,3#77 VSTello RIngram DOR:0RBil. '.f).D.O.R. : 0.. R.B #d... 'p%

-.,L O-

.,dRR D..O..R.: ^ 9/gYy-D 0... D 0E ome.

  • p..

,g_

..j -

LG e

ABurget;1

  • N ASchwenckr_.

KRGol l e r_._

_.._.5/h/77. 5/jh_77 5f[Z7 L >

z

._5/1U77_..

_. 5/ /.77

_ 5//W77 l rarm AEC-319 'Rev. f 53 7 Af CM 02n Tr u. s. nove nwrav eamtma ome rs ser4.sas.tes

t

y w.. :.

u..

~ E..

Uc::

.1.

y 5: ;=

Dockets Nos. 50-29 50-271 and 50-309-

=;

, m. i.=.

Mr. Louis J. Sirico, Jr.

ij -

Public Interest P.esearch Group g.1 1932 P Strect, E!.. Suite 101 F= =

il.;:g:.

'>ashington,.D.C.

20035 e

    • "J.-'.!'

[a.:=

Dear Mr. Siri This letter is q further response to your June 11, 1970 request which WM petitioned for Issuance of an Order to Show Cause pursuant to 10 CFR

~~~

2.206 on behalf of the !!ew England Coalition on Huclear Pollution and

=

Safe Power for T!ain You requested that an Order to Shou Cause be EE~

served on the license s of the Yankec-Rowe, Vermont Yankee, and Maine Yankee power plants to uspend their operating licenses for alleged

=;

deficiencies related to 'he quality assurance prncrar.s for theso x=::

plants.

185=

t:.=:.'.-

I Previously, in our letter you cated June 30, 1976, we acknowledgod reccist of your petition and aid we vould take the appropriate cctions

.and cdvise you of our decision \\on your request.

n.

4

\\

In %rt c' these actions, Yank e f. tonic Electric Co:.peny (YAEC), the

4 liccarne, he,s se!.mitted its Topica Report YSU.P-1, "Cperational N811ty /ssurance," catec Septe.cbcr\\l,1976. On Deccher 9,1975, and Jere1ary 13, 1977, YAEC cubmitted unt.ent to. I cnd t. enment ::o. 2 provide the updcted quality asser[ pert'end tne cr enrr.er.ts collectiwlv t3 tha rer.crt. YAEC's topicci re m..

e (LA) procran description for tbr anorational rnaso activitics invosvir.c. safety relcted structurcs,

=

systens and cc.?ponents at its Yankee-2 cue lemont Yenhee, ano U:ine Yanhoe facilitics.

s The WC staff has evaluated the GA progran de\\

E scribed in report YOGAP-I as amended. The staff has concluded that YAEC's DA program contains recuireaents and coritrols ubich, when properly 1,91cnented, c.rply

m..:

vith the requirrnents of Appendix 0 to Part 50 end fESI stance:rds contained in Section 17.2 of the 50 Standrd Revich Plan (hUPEG-79/N7) " Quality Assurance during the Operation: ihtsc,"

e

=

in swary, the stcff hcs concluded that th OA progrcrf described u aomcal Report YOMP-1 cs a.v;r.cc-i nectc the current EP.C remirerents t

t z.md is cccePuble for the operations chose of Yardce-?ce, Yar ont Yus.es, cad raine Yanken.

Proner imk-wt: tion e * &. r crnvvf orric a

  • t su== a u a *-

DATf b

?.T.C TOE?! 31f (f.76) NRC310240 k ur s. oovr.=w snt enmtmo c.ricts tsre -aze.ess

e

-r s

I:SE th. St rico li:5

.5.

==

OA prog..a will be verified by HRC's Office of Inspection and Enforce-9[

cent thrck.h periodic inspcetions at each facility. The criclosed W

copy of 'M 's letter to YAEC, dated April 4,1977, documents (AC'S h5j soproval of he topical OA program description and accepts its use at the operating ankee facilities.

s&l im+:

Since YAEC now ha an approved updated CA program description which Ei f teets regulatory re firements we believe that the cor.cern; that you

' ="

k en raised have been resol d and that there is-no basis for-an Order to Show Cause or for fur ! er action on the issues raised by yoer request.

E?jf...

Sincerely,

!Eb l5 :Esf tr. :i=:-ib Ben C. Rus (e, Director -

Office of !!ucDar Reector Regulation

.j;;g C

Enclosure:

-F f:PC letter to YAEC dated l

April 4, 1977

{::j.;

rr

=. :.

\\

. = ~ '-

~

DISTRIBUTION

\\

Dockets (50-29/271/309)

NRC PDRs LOCAL PDRS ORB #1 Reading

,. =. _

KRGoller VStello i:.

ASchwencer SMSheppard lM [

E^

p ABurger

! ===

L01shan JSiegel EGCase jf.

BCRusche

/

/

OELD ENON AN6N CED OI&E(3)

Oh

i=

4 chy'j en by -

/

c JRBuchanan

-y g,p,y j ll// F4'7 7 - l W iM 7 7

{.:

O NRR NRR DOR:@h DOI:0RB=1 DOR:0R/AD 00R:D orn:E

  • adidli ASchcer KRGoller VStello EGCase BCRusche

.v,.... v 4/.8/ 77._

_ 4// 2./77 4/._/77 4/ /77 __

4/_ /77 4/ /77 cus*

Nr.C TOTM 313 (9.%) tinCI C240 i' ur s. coVERNMENT PnmtmG OFMCEt 1HS = 424 424 h

?S: m

% %:l.-

Teii 4 1577

=

x =.

Yankee Atomic Electric Company ATTil: Mr. L. H. Heider fisssistant Vice President 20 Turnpise Rcad Westboro,11assachusetts 05181

Dear fir. Heider:

_.=

SUBJECT:

fiRC ACCEPTAf:CE OF YANKEE ATO'4IC ELECTRIC COMPANY QA T3PICAL REPORT We have evaluated Yankee Atomic Electric Company's (YAECo) topical report Y00AP-1, " Operational Quality Assurance Program" and /cendments l

Nos. I and 2 submitted with your December 9,1976, and January 13, 1977, aC ietters, respectively.

It is our understanding that changes identificd

',f;l; in /cendaents Hos, i and 2 uili be incorporated into YOQAP-1-A..We find.that the topicci report as amended describes an acceptable quality d',sUrance progrca for the operatior.s phase activities Cf those plants presently operating within YAEco's s; ope of work; i.e. the liaine Yankee, Vermont Yankee, and Yankee Roue facilities. Accordingly, you should amend the docr.ets for these facilities to reference YOQAP-1-A as the operations QA program description for these facilities and indicate when g

this -QA progran will be implemented at cach facility.

The acceptance of this program was based in part upon the staff's position (see enclosed CAB statenent) that GA progra ::atic/adninistrative require-ments contained in ANSI Nia.7-1976 including referenced standards apply to maintenance and nodification activities co1 ducted during the ooerations phase.

In addition, the qualifications of the Radiation Pcotection Super-visor established in the topical do not meet the staff's requirements for this position.

This subject will be addressed in separate correspondence.

Should rer;ulatory criteria or regulations change such that car conclusions about this topical report are invalidated, we will notify you. You will he given tne opportunity to revise and resubmit it should you so desire.

Programnatic chances by YAEco to this topical report are to be submitted to ISC for revieu prior to implementation. ' Organizational changes are to be submitted no later than 30 days after announcement.

==

h f0 2ID

==

=.

JRR e Gil

=

Mr. L. H. lief der =.....:i :

Please include a copy of this letter and the Topical Report Evaluation in cach report, and resutait 55 copics to the tiRC. Should you have are questions regarding our revievi or if we can profide assistsnee, please feel free to contact me or Mr. James Conway on (301) 492-7741.

=

Sincerely, Original signed by:

C. J. Helte es, Jr.

C. -J.

lici temes, Jr. Chief

=.

Quality Assurance Branch Division of Project !!anagement

~=

" ff Enclosures 1.

Topical Report Evaluation

=

2.

QAS Interpretation

b.

a

!S

,e

$s 1

=_

.C a+

e-l i

i

.+

&. a.;=;.

7 Ta',ph one 617 366-90it:

..-.L k==

.. [Ts no aa m-

==:

Cf TI "1 c Wyn 77.c M u w s u M u. J,'8 7.7 'U G u.~i W:.,4 f.f "[

  • r F.1, ? O,0 U/1.".7f(2 E n r.. r u s-a 55 f t.'!:W
WVY 77-48

.......7:.

fs u.:y 77 3o

.r e

=.:. n eg]

)',ANNicy.

' 20 Turnpoke Road Wostborough, l.iassachusotts 01581

%E

,. hi...mi.

=E fM

,f.*;, N i

=E ci e

~; O.

i=i May 4, 1977

@ g' gy\\

P3.

r-E=.r c Dgl

?..;* \\

=5E

.=:. -

. s. g L.p

==r gc3,g,ccAg

.==:

t

. :r.-

j; Un.tted States Mucicar Regulatory Co:c.ission

.A 9'5",,,$0#

/s //

Wachington, D. C.

20555

.

  • .CK

!q[,

7~

Attention: Office of-Nuclear Reactor Regulation b

-.=:rs h s

"=R :d I

Mr. Karl R. Gcller Division of Operating Beactors Oy-r=.

Enference:

(l')

License No. DPR-3 (Dccket No. 50-29)

FM (2)

Licenso No..DPR-23 (Decket No. 50-271),

. f.2$

(3)

Licence No. DPR-36 (Dechet No. 8:0-309) 25E?

(4)

YAEC Letter, dated May 2, 1977, Mr. L. H. Heider

.]

to Mr. C. J. Heltemos

= =j F

(5) USNRC Letter, dated April 4, 1977, Mr. C. J. Heltemes ZZ to Mr. L. H. Heider

Subject:

YAEC Rcqucst For Approval To Implement Y?tEC YOQAP-I-A Topical Report -

["

Dear Sir:

Our letter, References (4), in.resy.c7se to your letter, Reference (5),-

1[

previded 55 copics of the rKC-CI.E sccepted YAEC YOQ7.P-I-A Topical Ecrert, 5

inc'.uding the CAE Eveluation Report. The purpose of this letter is to ~

-y recyst r2pp cval-for tha impicncntation cf the Yankee Atemic Electric

~'.;;;;

Corpany Operational Quality Assurrlice Program (YOQAP-I-A) by amending the dockets to include this Program.

As inferred by your ictter, Reference (5), the effective date of c-.n'=

implementatien shall be not later than nincty (90) days following receipt of written notification that this Pregram has been approved for imple-rentz tion at tht three plants detailed in References (1), '(2), and (3).

We trust this meets your approval; hcuever, should you have any questions, please contact us.

I very truly yours, YANKEE ATOMIC ELECTRIC COMPANY 0

9 sM,dA r

L. H.

icider Asnist:.rit vice Prct:ident

. 5,'t.g

)

" ' '.'-iQ

.[

- ;;=-

maatCp

' UNITED STATES

~

gg NUCLEAR REGULATORY COMMisslON

j.; g;g ;

, y g WASHINGTON, D. C. 20555 3 %

=

%, ' ' ' /

K3y 17,1977

=

.=.;

Docket Nos. 50-29 50-271 and 50-309 g.g Yankee Atomic Electric Company ATIN: Mr. L. H. Heider Assistant Vice President 20 Turnpike Road

'destboro, Massachusetts 01581 Gentiemen:

By letter dated May '4,1977, you incorporated Topical Report " Yankee y,gg; At.,mic Electric Ccmpany, Operational Quality Assurance Program, g.;..

YOQAP-I-A, May 1,1977," by reference into the dockets for your Yankee-

=,,J.::.:s Rcwe, Vermont Yankee, and Maine Yankee facilities. Concurrently,

.23 :=

you requested NRC approval for use of the QA program at these facilities.

k's have previously found the QA program described in. Topical Report YOQAP-I-A to be acceptable as outlined in the April 4,1977 NRC letter to you from Mr. C. J. Heltemes, Jr., Chief, Quality Assurance Branch, Division of Project Management. The acceptance letter and our Topical Re;; ort Evaluation have also been incorporated into the above dockets by reference together with the QA Topical Report Y0QAP-I-A.

Based on our acceptance of your updated QA program descri.ption, i

icplementation of the QA program in Topical Report Y00AP-I-A, at l

the Yankee-Rowe, Vermont Yankee, and Maine Yankee facilities not later l

than 90 days from the cate of this letter, is hereby approved.

l Sincerely, k

"YM Karl R. Goller, Assistant Director for Operating Reactors Division of Operating Reactors cc:

Sea next page

= ~ '

plf L

L

!.~...

YknkteAtomicETectricCompary

' May

, 1977

.+

cc: Mr. Dcncid G. Allen, President Gregor I[McGregor, Escuire Yankee Atoaic Electric Company.

Assistant. Attorney General 20 Turnpike Road Department; of the Attorney General m ~

Westbcro, Massachusetts 01581 State Eo Ne, Room 370 Greenfield Public Library 402 Main Street Richard E. Ayres, Esquire W +=

Greenfield, Massachusetts 01581 Natural Resources Defense Council 917 - 15th Street, H. W.

E. W. Thurlow, President Washington, D. C.

20005 Maine Yankee Atomic Power Company 9 Green Street Honorable M. Jerome Diamond Augusta, Maine 04330 Attorney General Mr. Donald E. Vandenburgh 09 t te tet Y

Yice President - Engineering Yankee Atomic Electric Company Pavilion Office Building 20 turnpike Road Montpelier, Yemont 05602 5+ = ~

=

Westboro, Massachusetts 01581 John A. Calhoun John A. Ritsher, Esquire Assistant Attorney General 4

Ropes & Gray State of Yemont E #f 225 Franklin Street 109 State Street

_. ~.

= :;;

Boston, Massachusetts.02110 Pavilion Office,uilding e

Montpelier, Yemont 05602 Mr. John M. R. Paterson Assistant Attorney General Anthony 2. Roisman, Esquire State of Maine Berlin, Roisman and Kessler Augusta, Maine 04330 102515th Street, N.W., 5th Floor Washington, D. C.

20005 Harold P. Green, Esquire

"~.

Suite 1000 Brooks Memorial Library The Watergate 224 Main Street 600 New Hwpshire Avenue, N. W.

Brattleboro, Yemont 05301 Washington, D. C.

20037 Mr. Nicholas Barth John R. Stanton, Director Executive Director Radiation Control Agency Sheepscot Valley Conservation Hazen Drive Association, Inc.

P. O. Box 125 Concord, New Hampshire 03301-Alna, Maine 04535 John W. Stevens Wiscasset Public Library Association Conservation Society of High Street Southern Yemont P. O. Box 256 Wiscasset, Maine 04578 Townshend, Yemont 05353 Mrs. Cali Hollander, President

==

SAFE POWER FOR MAINE Stcckton Springs', Maine 04931

Yankee Atomic E.

ctri Company May 3.,, 1977

...=-

7; cc: Mr. David M. Scott Radiation Health Engineer

'~. ;..

Agency of Human Services g.::

Division of Occupational Health

.=

P. O. Box 607

.=

Barre, Yemont 05641 is

==;.;.

New England Coalition or.

== :

~=

Nuclear Pollution Hill and Dale Farm

~~~

"=

West Hill - Faraway Road Putney, Vermont 05346 Public Service Board

~ ~ ~ ~

State of Vermont 120 State Street 5=

Fantpelier, Yemont 05602

=r5g.
T.*~."

....: :.,.L Mr. S. D. Karpyak

]lf[:f nrmont Yankee Nuclear Power Corporation

'::.z=r F Grove Street i[t.i..!.!

Rutland, Vermont- 05701 Mr. Robert R. Radcliffe Office of Energy Resources 55 Capitol Street

=

Augusta, Maine 04330

.2 e

.e e.

.*?*.".'

2:-

...