Text
n.
.A Consumers power company
-- a --
Senior Vice l>esident General Officos: 1945 West Parnell Road, Jackson, Michigen 40201 e ($17) 7884453 October. 12, 1978 Howe 197-78 Director of. Nuclear Reactor Regulation Attn: Mr Roger Boyd, Director Division of Project Management US Huclear Regulatory Corunission Washington, DC 20555 MIDLAND PROJECT DOCKET NO 50-329, 50-330 REQUEST FOR ADDITIOJAL INFORMATION-PROPRIETARY INFORMATION RESPONSE FILE: 0505.8 SERIAL:
5947 Attached via certified mail, return receipt requested, is a duplicate original of a letter which I signed and sent to you on June 29, 1978. Since an original affidavit is involved, a resigned affidavit is provided. It is r:y understanding that you did not receive the signed original in the mail and desire one for your docketing and file procedures.
y&
M SHH/jg 1 S t o lt oo 6(,
4 s'
CORSum8fS Power g
Stephen H. Howell Vice l>esident Generet offices: 1945 West ParnaH Road, Jackson, Michigen 49201
- Area Code 517 788-0453 June 29, 1978 Hove 114-78 DUPLICATE ORIGINAL Director of Huclear Reactor Regulation Attn:
l'r Roger Boyd, Director Division of Project Management US Huclear Regulatory Commission Washington, DC 20555 MIDLAND PROJECT DOCKET H0 50-329, 50-330 REQUEST FOR ADDITIONAL INFORMATION-PROPRIETARY IHFORIMTION RESPONSE FILE:
0505.8 SERIAL:
5522 Amendment h5 to the Company's application for construction permits and operating licenses contained Revision 9 to the Final Safety Analysis Report.
In Revision 9, we indicated that our response to certain HRC Requests for Additional Information was proprietary in nature and would be submitted via separate cover.
We are enclosing five (5) copies of responses to the following NRC requests for additional information.
231.10 (4.2.1.6)
Design of Absorber Material 231.13 (4.2.1.6)
Conservatism of Minimum Unirradiated Strength Values 231.14 (4.2.1.7)
Fuel Surveillance 231.16 (4.2.3.1)
Fuel Rod Stresses 231.22 (k.2)
Dimensions / Spring Constants for Upper and Lover Plenum Springs We request that these responses be withheld fror' public disclosure, and in accordance with the provisions of 10CFR2.790(b), we are enclosing an affidavit prepared by Babcock & Wilcox which identifies the documents to be withheld from public disclosure and the basis for the request.
W 9
SHH/jbg