4 GPU Nuclear Corporation G N Nuclear "r 'n="*

Middletown, Pennsylvania 17057-0480 (717)944-7621 Writer's Direct Dial Number:

(717) 948-8005 June 7, 1993 C311-93-2070 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555

Dear Sir:

Subject:

Three Mile Island Nuclear Generating Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request (TSCR) No. 225 9

Cycle 10 Core Design In accordance with 10 CFR 50.4(b)(1), enclosed is Technical Specification Change Request No. 225.

Also enclosed is the Certificate of Service for this request certifying service to the chief executives of the township and county in which the facility is located, as well as the designated official of the Commonwealth of Pennsylvania, Bureau of Radiation Protection.

The purpose of this TSCR is to request that the TMI-l Technical Specifications be revised to reflect the inclusion of gadolinia-urania in the fuel rod design description, revised boron concentration requirements and Bases clarifications, and provide reference to Topical Report BAW-10179P which has been approved by NRC and consolidates the methodologies used to establish the operating limits contained in the Core Operating Limits Report.

Pursuant to 10 CFR 50.51(a)(1), enclosed is our analysis, applying the standards in 10 CFR 50.92 to make a determination of no significant hazards considerations. As stated above, pursuant to 10 CFR 50.91(a), we have provided a copy of this letter, the proposed change in Technical Specifications, and our analyses of significant hazards considerations to Richard R. Janati, the designated representative of the Commonwealth of Pennsylvania.

/ld J

9306140016 930607 T

DR ADOCK 0500 9

GPU Nuclear Corporation is a subsidiary of General Public Utihties Corporation

Document Control Desk C311-93-2070 Page 2 GPUN requests issuance of this amendment by. September 1, 1993 to support Cycle 10 startup.

Sincerely,

?

T.G.Broughyan Vice President and Director, TMI-I DJD/amk

Enclosures:

(1) Technical Specification Change Request No. 225 (2) Certificate of Service for Technical Specification Change Request No. 225 cc: Administrator, Region I TMI Senior Resident Inspector THI-l Senior Project Manager I

L 4

-