Sou:nern Nxtear 0;mra:#ng Company Post OSce Bom 1295 Birmingham. Alabama 35201 Telephone 205 668 5086 A

Southern Nuclear Operating Company

, 0. m.,,,,,

ll,TelN$,'

U* 5 "*'am etecnic sistem May 11,1993 Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C.

20555 Gentlemen:

Joseph M. Farley Nuclear Plant Unit I and 2 Monthly Operatina Data Report s Attached are the April 1993 Monthly Operating Reports for Joseph M. Farley Nuclear Plant Units 1 and 2, as required by Section 6.9.1.10 of the Technical Specifications.

If you have any questions, please advise.

Respectfully submitted, N

f' h L d N J\\

J. D. Woodard FMJ:scj04-4351 Attachments cc: Mr. S. D. Ebneter Mr. T. A. Reed Mr. G. F. Maxwell

-9305170293 930430

'PDR ADOCK'0500034G.

I g

R pyg

l 3

.. t bc: Mr. W. G. Hairston, Ill Mr. R. D. Hill (G9.03 & A4.05)

Mr. J. R. Derieux 4

Mr.'J. M. Elliott

-l Mr. D. J. Shelton l

Mr. R. G. Cocherell Mr. O. Batum Mr. C. L. Whatley l

Mr. D. W. Glass Mr. R. E. Huffman Mr. Clem Eicheldinger Mr. M. G. McCorkle i

Mr. John Hoffman Mr. Russ Dedrickson Hr. Fred Yost Mr. F. M. Jessup, III INPO Records Center ANI Library Commitment Tracking System (2 copies)

File: A2.1 Document Control (I copy)

{

t I

r

'i i

a I

1 L

{

h

[

b

OPERATING DATA REPORT i

i DOCKET NO.

50-348 DATE May 5.1993 COMPLETED BY R. D. Hill TELEPHONE (205) 899-5156 OPERATING STATUS s

1. Unit Name:

Joseoh M. Farley - Unit 1 Notes

2. Reporting Period:

April 1993

1) Cumulative data since i
3. Licensed Thermal Power (MWt):

2.652 12-1-77, date of

4. Nameplate Rating (Gross MWe):

860 commercial operation

5. Design Electrical Rating (Net MWe): 829
6. Maximum Dependable Capacity (Gross MWe):

855.7

7. Maximum Dependable Capacity (Net MWe):

812.0

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: N/A
9. Power Level To Which Restricted, If Any (Net MWe):

N/A

10. Reasons for Restrictions, If Any:

N/A i

This Month Yr-to-Date Cumulative i

11. Hours In Reporting Period 719.0 2.879.0 135.119.0
12. Number Of Hours Reactor Was Critical 719.0 2.661.6 105.782.9
13. Reactor Reserve Shutdown Hours 0.0 0.0 3.650.0 14 Hours Generator On-Line 719.0 2.641.9 104.025.6 i
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (MWH) 1.905.594.6 6.902.990.3 266.904.066.1
17. Gross Electrical Energy Generated (MWH) 617.280.0 2.237.992.0 86.004.794.0
18. Net Electrical Energy Generated (MWH) 586.360.0 2.117,696.0 81.183.946.0
19. Unit Service Factor 100.0 91.8 77.0
20. Unit Availability Factor 100.0 91.8 77.0
21. Unit Capacity Factor (Using MDC Net) 100.4 90.6 73.7
22. Unit Capacity Factor (Using DER Net) 98.4 88.7 72.5
23. Unit Forced Outage Rate 0.0 8.2 6.7
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: N/A
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 08/06/77 08/09/77 INITIAL ELECTRICITY 08/20/77 08/18/77 COMMERCIAL OPERATION 12/01/77 12/01/77 DATARPT.U1 l

~

l t

DOCKET NO.

50-348 UNIT 1

l DATE May 5. 1993 i

COMPLETED BY R. D. Hill u

TELEPHONE (205) 899-5156

[.

l 1

1 I

MONTH April 5

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) l 1

817 17 818 l

2 819 18 818 3

820 19 817 l

l 4

784 20 815 l

5 816

.21 815 i

6 820 22 818 t

i 7

819 23 819 l

8 817 24 817 9

814 25 812 l

l l

10 816 26 809 l

11 800 27 816 12 815 28 816 l

13 812 29 817 l

14 815 30 814 15 811 31 N/A 1

l-16 818 1

INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

p l

~.

i JOSEPH M. FARLEY NUCLEAR PLANT l

UNIT 1 1

NARRATIVE

SUMMARY

OF OPERATIONS l

April 1993 l

1 There were no unit shutdowns or major power reductions during the month of April.

l The following major safety related maintenance was performed during the month:

1.

Performed miscellaneous corrective and preventive maintenance on the diesel generators.

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCCETWO.

50-349 UNIT MAME:

J. M. Farfey - Unit 1 DATE May 5.1993 COMPLETED BY R D. Mit REPORT MONTH: Aprit.

TELEPHONE (2051 899 5156.

P METHOD OF UCENSEE CAUSE & CORRECTIVE DURATION SHUTTING EVENT SYSTEM COMPONENT ACTION TO NO.

DATE TYPE' (HOURS)

REASON' DOWN REACTOR' REPORT #

CODE

  • CODE
  • PREVENT RECURRENCE Thore were no unit shutdowns or major power reductions during the month of April.

I 1:

2:

3.

4:

5:

. F: Forced Reason:

Method:

Exhibit G-Instructions for.

Dhibi' I - Same Source S: Scheduled A Equipment Failure (bplain) 1 - Manual Preparations for Data Entry B Maintenance or Test 2 Manual Scram.

Sheets for Licensee Event C - Refueling -

3-Automatic Scram.

Report (LER) Fi!e (NUREG4161) -

D - Regulatory Restriction 4 - Other (bplain)

E Operator Training & Ucensing Examination F-Administrative G - Operational Error (Explain) -

H - Other (Splain)

~.. - - -.

- -.,. ---- -_._-.,.., -. ~.., - -...... _........... -.. _ _... _.. _.. - _ _.,,..

OPERATINn DATA REPORT DOCKET NO.

50-364 i

DATE May 5. 1993

[

COMPLETED BY R. D. Hill TELEPHONE (205) 899-5156 OPERATING STATUS l

1. Unit Name:

Joseph M. Farley - Unit 2 Notes

2. Reporting Period:

April 1993

1) Cumulative data since
3. Licensed Thermal Power (MWt):

2.652 7-30-81, date of

4. Nameplate Rating (Gross MWe):

860 commercial operation

5. Design Electrical Rating (Net MWe): 829
6. Maximum Dependable Capacity (Gross MWe):

863.6 e

7 Maximum Dependable Capacity (Net MWe):

822.0 i

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:

N/A

9. Power Level To Which Restricted, If Any (Net MWe):

N/A

10. Reasons For Restrictions, If Any:

N/A This Month Yr-to-Date Cumulative i

11. Hours In Reporting Period 719.0 2.879.0 103.032.0
12. Humber Of Hours Reactor Was Critical 719.0 2.820.0 88.841.9
13. Reactor Reserve Shutdown Hours 0.0 0.0 138.0
14. Hours Generator On-Line 719.0 2.625.0 87.541.7
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (MWH) 1.885.890.2 6.815.583.7 223.346.531.5 i
17. Gross Electrical Energy Generated (MWH) 620.266.0 2.241.760.0 73.253.938.0
18. Het Electrical Energy Generated (MWH) 590.866.0 2.127.784.0 69.466.982.0
19. Unit Service Factor 100.0 91.2 85.0
20. Unit Availability Factor 100.0 91.2 85.0
21. Unit Capacity Factor (Using MDC Net) 100.0 89.9 82.3
22. Unit Capacity Factor (Using DER Net) 99.1 89.2 81.3
23. Unit Forced Outage Rate 0.0 8.8 4.2
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

Refuelina/ Maintenance Outaae September 24. 1993 Approximately 60 days

25. If Shut Down At End Of Report Period, Estimated Date of Startup: N/A
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CPITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81 05/25/81 COMMERCIAL OPERATION 08/01/81 07/30/81 DATARPT.U2

DOCKET N0.

50-364 UNIT 2-DATE May 5. 1993 COMPLETED BY R. D. Hill l

TELEPHONE (205) 899-5156 l

MONTH April DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL

-l (MWe-Net)

(MWe-Net)

{

l 824 17 818 2

827 18 809 3

828 19 824 4

790 20 822 5

822 21 822 f

I 6

824 22 827 7

823 23 827 i

8 820 24 823 l

I 9

818 25 818 10 823 26 818 11 823 27 825 12 821 28 823 i

13 820 29 822 14 819 30 820 I

i 15 817 31 N/A 16 825 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

{

i AVGDLY.PWR i

,i

JOSEPH M. FARLEY NUCLEAR PLANT UNIT 2 I

NARRATIVE

SUMMARY

OF OPERATIONS April 1993 There were no unit shutdowns or major power reductions during the month of April.

The following major safety-related maintenance was performed during the month:

1.

Miscellaneous corrective and preventive maintenance was performed on the diesel generators.

l i

3 I

il l

UNIT SHIRDOWNS AND POWER REDUCTIONS GCCKETMO.

50-364 UNtT NAME J. M. Fadev Unit 2 DATE May 5.1993 COMPLETED BY R D. Hi!!

_Acril_

TELEPHONE (205) 899-5150 REPORT MONTH:

i METHOD OF LICENSEE CAUSE & CORRECTIVE DURATON SHUTTING EVENT SYSTEM COMPONENT ACTON TO NO.

DATE TYPE' (HOURS)

REASON' DOWN REACTOR' REPORT #

CODE

  • CODE
  • PREVENT RECURRENCE There were no unit shutdowns or major power reductions during the month of April i

i 1:

2.

3:

- 4; S:

F: Forced Reason:

Method.

Exhibit G-Instructions for Exhibit 1 - Same Source j

S: Scheduled A e Equipment Failure (Explain) 1 - Manual Preparations for Datt Entry B - Maintenance of Test 2 - Manual Scram.

Sheets for Licensee Event l

C - Refueling Automatic Scram.

Report (LER) File (NUREG4161)

D - Regulatory Restriction -

4 Other (Esplain) j E Operator Training & Licensing Examination i

F Administrative G - Operations! Error (Explain)

H - Other (Explain) i I

__.m__w__--___-_m,-----r+--.-ww-e--w-ce.-*w w w.v w -

m..

--v4eed--ww e--w.,w

-e*

.--+-ewe,'-==e m v

= w,vu'w_.-.-

ww e-

=---w,-'.-,we==w

==m.-eurr.-W.e-

+--

.ww+

-1+--.d4w--'.

w.--a% vee.-..ww-

-m..

-