ML20036A798

From kanterella
Jump to navigation Jump to search
Application for Amend to License R-75,changing TS 3.2.3.13 to State That Rod Drop Will Occur for Any Control Rod Which Has Excess Magnet Current of Plus or Minus 100 Ma.Results of Magnet Current Testing Encl
ML20036A798
Person / Time
Site: Ohio State University
Issue date: 05/05/1993
From: Cruz J
OHIO STATE UNIV., COLUMBUS, OH
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9305170001
Download: ML20036A798 (4)


Text

)

1 i

l T-HE Engineering Experiment Station 167 Hitchcock Hall 2070 Neil Avenue

' ~

~

~"

Columbus, OH 43210-1275 k'

Phone 614-292-4903

,R,,j FAX # 614-292-9021

)

UNIVERSITY,

f 1

May 5, 1993 j

Docment Control Desk US Nuclear Regulatory Cocmission

)

Washington D.C.

20555

Subject:

Request for Technical Specification Change at The Ohio State University Research Reactor (OSURR), License R-75, Docket No. 50-150.

On March 24, 1993 the NRC granted a waiver of Technical Specificati m (T.S.)

3.2.3.13 for a period of 15 days to allow measurement of rod drop times with magnet currents up to 100 m.

The purpose was to determine if while operating with magnet currents at 100 ma the rods would be inserted in less than 600 milliseconds as required by Technical Specification 3.2.1.

The staff of the OSURR conpleted this testing on March 25, 1993; April 1,1993; and April 2, 1993. The results are attached.

It is the conclusion of the OSURR staff that T.S. 3.2.1 will be met with magnet currents as high as 100 ma and therefore T.S. 3.2.3.13 should be amended to read as follows:

Rod drop will occur for any control rod which has excess magnet current a 100 ma.

The results of the testing and proposed Technical Specification change were also reviewed and approved by the Reactor Operations Cmmittee at their April 14, 1993 meeting as required by T.S. 6.2.4(3).

If you have questions on this proposed Technical Specification Change please contact Mr. Richard Myser at 614-292-6755.

Since ely,

(

ose B. Cru, Jr., Director cc.

with enclosure Don W. Mi11er, OSUNRL Richard D. Myser, OSUNRL Theodore S. Michaels, US!ac I

140092 l

PJH/lv 9305170001 930505 j /\\d l

PDR ADOCK 05000150 College of Engineering i

P PDR m_.

7 l

I i

1 Magnet Current i

2 29-3)

Min.

40 ma.50 ma.60 ma.70 ma.80 ma.90 ma.100 ma.

5 cm.

/u.I

  1. 4. 7 tot.3 113.6 19 0 IM8

/7;r.6

/7s t, 10 cm.

213.6 2l'i.t

~L 1'7 3

" ?1. 6 724.D 224 7-Z.24.f 7 24. 4 20 cm.

Ib2.4 795.$

7c8. I 21/.o tvi <"

774.t 75 L 2MA'L-i 6

0 cm.

54,, 5 3 g,2

-4i.6 W>

540 4 547 9 9tF. 6

'i%.6 40 cm.

T/. 8

%S.$

WoG M 6.D 317.L 5 'iC F-34'E 9 deo./

50 cm.

+33.i 453.tr 4 %. (,,

430. e at. A 444 5 4A3. t, 44c 4 I

60 cm.

ec. t o 44.s A Fo. L it 2.1

47. D 4e 9.0

<en.1 Mto. s Nic. +

t Rod Height Time, milliseconds Shim Safety Rod #1 Date:

4-2-43 Operator:

m Reviewed by:

C!dL h7kyJ.4%

y 9

)

d

7 4

i i

l t

Magnet Current i

i

'> 6t = A Min.

40 ma.50 ma.60 ma.70 ma.80 ma.90 ma.100 ma.

177.4 i

5 cm.

/43.I

/ce.4 f f 2. 4

'97.7 m

n r. 2-94.7-

/ 9 f. t j

i 10 cm.

t 314.I 227.9 2 Lt. f 727. ~P Mb 776.3 2 2't. G tt 7. 4 l

i IM.k 7 29. D 140.4 ZA 2,'?-

3cc. s' ' To2.1 294,9-29 5. G i

I 30 cm.

345.1 wf, t 552,9 MS. ?

5 $5. /

550 5 sff. 3 3 52. 6 40 cm.

666.5 3'17. (

3 't's. l Mi. i 403,(

3 't8.1 M9. I 1401. 0

)

50 cm.

4 M. )-

435.6 440. L 441.9-444.'l 444.3 4+i. c 445;9 60 cm.

4EA 'S 484A 46'l >f 45#')

N l' #

43l U 49'*6 O I-M. < 6 1

Rod Height Time, milliseconds t

Shim Safety Rod #2 i

4"("i)

Date:

I p.a W Operator:,

/

//

d 1

Revie ed by:

C[vfi

' di fu/JA__

s]

i 4

I

Magnet Current t ab A.

Min.

40 ma.50 ma.60 ma.70 ma.80 ma.90 ma.100 ma.

'0&'5 IM b 199.7 1%.b

/Pr.4 l60.(

IG I.L

/FJ-3 10 cm.

ZM 5 2 z 6. 2-tz9.o 22s.5 5 52.c, en c 7 v -2 155 \\

tee.3 294 5 7,14. 4 29S. o 198.o se t. t sec, e>

sw.L 30 cm.

345 L 352.4-353.4 2A9.5 352 9 35/.5

%,. 3 555 3 40 cm.

Sf s. 7 4c t.4 Jel. l 3 78 l, 4CB.2.

4c35

@ 5. 0 404. ?

50 cm.

442. G 447.4 445.B 4%.l 4 50.3-4 52.I 1452. t 453, g

/ /5 fE4. Z 493.1 444.f M.Y 414. &

499.O 4ctt4 5ec.I Rod Height Time, milliseconds Shim Safety Rod #3

[

Date: n iude 9 3 C

Operatopf

\\

7[h,C Revi y

LC d J