May 6, 1993 Docket Nos. 50-416, 50-440, 50-458, and 50-461 LICENSEE:

Illinois Power Company FACILITY: Clinton Power Station

SUBJECT:

MEETING

SUMMARY

OF APRIL 27, 1993 On April 27, 1993, representatives of Illinois Power Company (IP) representing both themselves and the Hydrogen Control Owner's Group (HCOG) met with members of the NRC staff at NRC headquarters in Rockville, Maryland, to di.scuss resolution of the HCOG's submittals on hydrogen control in accordance with i

10 CFR 50.44 for BWR6 Mark Ill containments.

A list of attendees is enclosed.

Illinois Power Company representatives provided a brief discussion of the HC0G's activities and current status.

The BWR6 licensees formed the HCOG and funded one-quarter scale testing to demonstrate compliance with 10 CFR 50.44.

Generic testing was performed to demonstrate the overall concept while production runs were made with appropriate modeling to represent plant-specific characteristics.

A topical report was submitted and the staff published a safety evaluation (SE) regarding the generic approach in August 1990. The HCOG took a number of exceptions to the staff's SE which, to this date, have not been resolved Due to a recent reorganization and transfer of responsibilities, new reviewers have been assigned to this issue. The staff indicated that the new review team will review the most recent correspondence and prepare a supplement to the SE. Upon resolution of the exceptions, the HCOG will resubmit the topical report with a copy of the staff's SE.

Within six months of this submittal, each of the four BWR6 Mark III licensees will submit plant-specific reports.

The staff did not have a review schedule available but indicated that one would be prepared in the near future.

OdginalSigned By:

Douglas V. Pickett, Senior Project Manager Project Directorate III-2 Division of Reactor Projects Ill/IV/V Office of Nuclear Reactor Regulation

Enclosure:

DISTRIBUTION Docket File NRC & Local PDRs As Stated PDill-2 r/f JRoe TMurley/FMiraglia CMoore OGC EJordan cc w/ enclosure:

RLobel DPickett GGrant, EDO See next page BClayton, Rlll JZwolinski MVirgilio JDyer JHannon SBlack l

JPellet RBarrett WLono JKudrick RStransky PO'C6nnor l

EBake ACRS(10)

JPartlow,

1

,s D/PDIIIk' LA I-2 P

Dill-2

/S B ore DPickett:rc RB rett JDyer g/@93 i/ 4 /93

/

3 g/(p/93 r}

l 9305140094 930506

[

EC F!E CB?T "'Y i

i cc:

Grand Gulf Nuclear Station Mr. H. W. Keiser, President and Chief Executive Officer GGNS General Manager Entergy Operations, Inc.

Entergy Operations, Inc.

P. O. Box 31995 P. O. Box 756 1

Jackson, Mississippi 39286-1995 Port Gibson, Mississippi 39150 i

Robert B. McGehee, Esquire The Honorable William J. Guste, Jr.

Wise, Carter, Child & Caraway Attorney General j

l P. O. Box 651 Department of Justice

{

l Jackson, Mississippi 39205 State of Louisiana P. O. Box 94005 l

Nicholas S. Reynolds, Esquire Baton Pouge, Louisiana 70804-9005 Winston & Strawn 1400 L Street, N.W. - 12th Floor Alton B. Cobb, M.D.

Washington, D.C.

20005-3502 State Health Officer State Board of Health Mr. Sam Mabry, Director P. O. Box 1700 Division of Solid Waste Management Jackson, Mississippi 39205 Mississippi Department of Natural i

Resources Office of the Governor P. O. Box 10385 State of Mississippi Jackson, Mississippi 39209 Jackson, Mississippi 39201 President, Mike Morre, Attorney General Claiborne County Board of Supervisors Frank Spencer, Asst. Attorney General Port Gibson, Mississippi 39150 State of Mississippi Post Office Box 22947 Regional Administrator, Region II Jackson, Mississippi 39225 U.S. Nuclear Regulatory Commission 101 Marietta St., Suite 2900 Mr. John P. McGaha Atlanta, Georgia 30323 Vice President, Operations Support Entergy Operations, Inc.

Mr. Michael J. Meisner P.O. Box 31995 Director, Nuclear Licensing Jackson, Mississippi 39286-1995

~

Entergy Operations, Inc.

P. O. Box 756 Mr. S. S. Chan Port Gibson, Mississippi 39150 Project Engineer Bechtel Power, Corporation Mr. K. G. Hess P.O. Box 2166 Bechtel Power Corporation Houston, Texas 77252-2166 P. O. Box 2166 Houston, Texas 77252-2166 Mr. C. Randy Hutchinson Entergy Operations, Inc.

Mr. Rudolph H. Bernhard P. O. Box 756 Senior Resident Inspector Port Gibson, Mississippi 39150 U.S. Nuclear Regulatory Commission Route 2, Box 399 Port Gibson, Mississippi 39150

I Perry Nuclear Power Plant Cleveland Electric Illuminating Company Unit Nos. I and 2 cc:

Jay E. Silberg, Esq.

Mr. James W. Harris, Director Shaw, Pittman, Potts & Trowbridge Division of Power Generation 2300 N Street, N.W.

Ohio Department of Industrial Relations Washington, D.C.

20037 P. O. Box 825 Columbus, Ohio 43216 Mary E. O'Reilly Centerior Energy Corporation The Honorable Lawrence Logan 300 Madison Avenue Mayor, Village of Perry j

Toledo, Ohio 43652 4203 Harper Street Perry, Ohio 44081 i

Resident Inspector's Office The Honorable Robert V. Orosz I

U.S. Nuclear Regulatory Commission Mayor, Village of North Perry Parmly at Center Road North Perry Village _ Hall Perry, Ohio 44081 4778 Lockwood Road North Perry Village, Ohio 44081 l

Regional Administrator, Region III i

U.S. Nuclear Regulatory Commission Attorney General 799 Roosevelt Road.

Department of Attorney General I

Glen Ellyn, Illinois 60137 30 East Broad Street j

Columbus, Ohio 43216 Frank P. Weiss, Esq.

j 1

Assistant Prosecuting Attorney Radiological Health Program j

105 Main Street Ohio Department of Health Lake County Administration Center Post Office Box 118 i

Painesville, Ohio 44077 Columbus, Ohio 43266-0118 i

Ms. Sue Hiatt Ohio Environmental Protection Agency OCRE Interim Representative DERR--Compliance Unit 8275 Munson ATTN: Zack A. Clayton Mentor, Ohio-44060 P. O. Box 1049 Columbus, Ohio 43266-0149 Terry J. Lodge, Esq.

618 N. Michigan Street, Suite 105 Mr. Phillip S. Haskell, Chairman i

Toledo, Ohio 43624 Perry Township Board of Trustees i

4171 Main Street, Box 65 Perry, Ohio 44081 Prosscuting Attorney Ashtabula County Courthouse State of Ohio-Jefferson, Ohio 44047 Public Utilities Commission East Broad Street i

Mr. Kevin P. Donovan Columbus, Ohio. 43266-0573 l

Cleveland Electric 1

Illuminating Company Mr. David P. Igyarto, General Manager l

Perry Nuclear Power Plant Cleveland Electric Illuminating Company l

P. O. Box 97, E-210 Perry Nuclear Power Plant Department Perry,~ Ohio 44081 Post Office Box 97, SB306 Perry, Ohio -44081-t Mr. Robert A. Stratman, Vice President Nuclear - Perry e

The Cleveland Electric illuminating Company 10 Center Road Perry, Ohio 44081' f

l

i l

River Bend, Unit No. 1 CC:

i Winston & Strawn Gulf States Utilities ATTN: Mark J. Wetterhahn, Esq.

ATTN: Mr. Philip D. Graham 1400 L Street, N.W.

Vice President, (RBNG)

Washington, D.C. 20005-3502 Post Office Box 220 St. Francisville, Louisiana 70775

[

Director - Nuclear Licensing Gulf States Utilities Company St. Francisville, Louisiana 70775 Mr. Philip G. Harris Cajun Electric Power Coop, Inc.

10719 Airline Highway P. O. Box 15540 i

Baton Rouge, Louisiana 70895 l

Senior Resident Inspector P. O. Box 1051 St. Francisville, Louisiana 70775 President of West Feliciana Police Jury L

P. O. Box 1921 St. Francisville, Louisiana 70775 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission i

611 Ryan Plaza Drive, Suite 1000 l

Arlington, Texas 76011 Mr. J. David McNeill, III William G. Davis, Esq.

Department of Justice Attorney General's-Office P. O. Box 94095 Baton Rouge, Louisiana 70804-9095 Ms. H. Anne Plettinger 3456 Villa Rose Drive Baton Rouge, Louisiana 70806 Administrator Louisiana Radiation Protection Division P. O. Box 82135 Baton Rouge, Louisiana. 70884-2135 I

n

+-

.,.m,

cc:

Clinton Power Station Unit No. I Mr. J. S. Perry Illinois Department Vice President of Nuclear Safety Clinton Power Station Office of Nuclear Facility Safety Post Office Box 678 1035 Outer Park Drive Clinton, Illinois 61727 Springfield, Illinois 62704 Mr. J. A. Miller Mr. Donald Schopfer Manager Nuclear Station Project Manager Engineering Department Sargent & Lundy Engineers Clinton Power Station 55 East Monroe Street Post Office Box 678 Chicago, Illinois 60603 Clinton, Illinois 61727 Mr. Frank A. Spangenberg Sheldon Zabel, Esquire Manager - Licensing and Safety Schiff, Hardin & Waite Clinton Power Station 7200 Sears Tower Post Office Box 678 233 Wacker Drive Mail Code V920 Chicago, Illinois 60606 Clinton, Illinois 61727 Resident Inspector U.S. Nuclear Regulatory Commission RR#3, Box 229 A Clinton, Illinois 61727 Ms. K. K. Berry Licensing Services Manager General Electric Company 175 Curtner Avenue, M/C 382 San Jose, California 95125 Regional Administrator, Region III 799 Roosevelt Road, Building 4 Glen Ellyn, Illinois 60137

)

Chairman of DeWitt County c/o County Clerk's Office DeWitt County Courthouse Clinton, Illinois 61727 Mr. Robert Neumann Office of Public Counsel State of Illinois Center 100 W. Randolph, Suite 11-300 Chicago, Illinois 60601 l

l

ENCLOSURE APRIL 27. 1993 I

NEETING ATTENDEES I

NRC ILLIN0IS POWER J. Kudrick R. Phares i

R. Lobell R. Langley l

W. Long T. Byam l

l D. Pickett l

1 i

r Occ}ti k

'o UNITED STATES E' y ]9p NUCLEAR REGULATORY COMMISSION l

W A SHINGTON. D. C. 20555 g

k...../

May 6, 1993

?

Docket Nos. 50-416, 50-440, 50-458, and 50-461 LICENSEE:

Illinois Power Company FACILITY:

Clinton Power Station

SUBJECT:

MEETING

SUMMARY

OF APRIL 27, 1993 On April 27, 1993, representatives of Illinois Power Company (IP) representing both themselves and the Hydrogen Control Owner's Group (HCOG) met with members of the NRC staff at NRC headquarters in Rockville, Maryland, to discuss resolution of the HCOG's submittals on hydrogen control in accordance with 10 CFR 50.44 for BWR6 Mark III containments.

A list of attendees is enclosed.

Illinois Power Company representatives provided a brief discussion of the t

HC0G's activities and current status.

The BWR6 licensees formed the HCOG and funded one-quarter scale testing to demonstrate compliance with 10 CFR 50.44.

Generic testing was performed to demonstrate the overall concept while production runs were made with appropriate modeling to represent plant-specific characteristics.

A topical report was submitted and the staff published a safety evaluation (SE) regarding the generic approach in August 1990. The HCOG took a number of exceptions to the staff's SE which, to this date, have not been resolved.

Due to a recent reorganization and transfer of responsibilities, new reviewers have been assigned to this issue.

The staff indicated that the new review team will review the most recent correspondence and prepare a supplement to the SE. Upon resolution of the exceptions, the HCOG will resubmit the topical report with a copy of the staff's SE. Within six months of this submittal, each of the four BWR6 Mark III licensees will submit plant-specific reports.

The staff did not have a review schedule available but indicated that one would be prepared in the near future.

V?

Douglas V. Pickett, Senior Project Manager Project Directorate III-2 Division of Reactor Projects III/IV/V l

Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

j See next page

r.

cc:

Grand Gulf Nuclear Station Mr. H. W. Keiser, President and Chief Executive Officer GGNS General Manager Entergy Operations, Inc.

Entergy Operations, Inc.

P. O. Box 31995 P. O. Box 756 Jackson, Mississippi 39286-1995 Port Gibson, Mississippi 39150 Robert B. McGehee, Esquire The Honorable William J. Guste, Jr.

Wise, Carter, Child & Caraway Attorney General P. O. Box 651 Department of Justice Jackson, Mississippi 39205 State of Louisiana i

P. O. Box 94005 Nicholas S. Reynolds, Esquire Baton Rouge, Louisiana 70804-9005 Winston & Strawn 1400 L Street, N.W. - 12th Floor Alton B. Cobb, M.D.

Washington, D.C.

20005-3502 State Health Officer State Board of Health Mr. Sam Mabry, Director P. O. Box 1700 Division of Solid Waste Management Jackson, Mississippi 39205 Mississippi Department of Natural Resources Office of the Governor P. O. Box 10385 State of Mississippi Jackson, Mississippi 39209 Jackson, Mississippi 39201 1

President, Mike Morre, Attorney General Claiborne County Board of Supervisors Frank Spencer, Asst. Attorney General Port Gibson, Mississippi 39150 State of Mississippi Post Office Box 22947 Regional Administrator, Region 11 Jackson, Mississippi 39225 U.S. Nuclear Regulatory Commission 101 Marietta St., Suite 2900 Mr. John P. McGaha l

Atlanta, Georgia 30323 Vice President, Operations Support 1

Entergy Operations, Inc.

Mr. Michael J. Meisner P.O. Box 31995 Director, Nuclear Licensing Jackson, Mississippi 39286-1995 Entergy Operations, Inc.

P. O. Box 756 Mr. S. S. Chan Port Gibson, Mississippi 39150 Project Engineer l

Bechtel Power, Corporation l

Mr. K. G. Hess P.O. Box 2166 l

Bechtel Power Corporation Houston, Texas 77252-2166 P. O. Box 2166 Houston, Texas 77252-2166 Mr. C. Randy Hutchinson i

Entergy Operations, Inc.

Mr. Rudolph H. Bernhard P., O. Box 756 Senior Resident Inspector Port Gibson, Mississippi 39150 U.S. Nuclear Regulatory Commission l

Route 2, Box 399 Port Gibson, Mississippi 39150

i Perry Nuclear Power Plant Cleveland Electric Illuminating Company Unit Nos. I and 2 i

cc:

Jay E. Silberg, Esq.

Mr. James W. Harris, Director Shaw, Pittman, Potts & Trowbridge Division of Power Generation 2300 N Street, N.W.

Ohio Department of Industrial Relations Washington, D.C.

20037 P. O. Box 825 Mary E. O'Reilly Centerior Energy Corporation The Honorable Lawrence Logan j

300 Madison Avenue Mayor, Village of Perry Toledo, Ohio 43652 4203 Harper Street Perry, Ohio 44081 Resident Inspector's Office The Honorable Robert V. Orosz U.S. Nuclear Regulatory Commission Mayor, Village of North Perry Parmly at Center Road North Perry Village Hall Perry, Ohio 44081 4778 Lockwood Road Regional Administrator, Region III i

U.S. Nuclear Regulatory Commission Attorney General 799 Roosevelt Road Department of Attorney General Glen Ellyn, Illinois 60137 30 East Broad Street Frank P. Weiss, Esq.

Assistant Prosecuting Attorney Radiological Health Program 105 Main Street Ohio Department of Health

[

Lake County Administration Center Post Office Box 118 Painesville, Ohio 44077 Columbus, Ohio 43266-0118 Ms. Sue Hiatt Ohio Environmental Protection Agency OCRE Interim Representative DERR--Compliance Unit 8275 Munson ATIN:

Zack A. Clayton Mentor, Ohio 44060 P. O. Box 1049 Columbus, Ohio 43266-0149 Terry J. Lodge, Esq.

618 N. Michigan Street, Suite 105 Mr. Phillip S. Haskell, Chairman Toledo, Ohio 43624 Perry Township Board of Trustees 4171 Main Street, Box 65 Perry, Ohio 44081 Prosecuting Attorney Ashtabula County Courthouse State of Ohio Jefferson, Ohio 44047 Public Utilities Commission East Broad Street i

Mr. Kevin P. Donovan Lolumbus, Ohio 43266-0573 Cleveland Electric Illuminating Company Mr. David P. Igyarto, General Manager j

Perry Nuclear Power Plant Cleveland Electric illuminating Company P. O. Box 97, E-210 Perry Nuclear Power Plant Department i

Perry, Ohio 44081 Post Office Box 97, SB306 1

Perry, Ohio 44081 i

Mr. Robert A. Stratman, Vice President Nuclear - Perry The Cleveland Electric Illuminating Company 10 Center Road Perry, Ohio 44081 i

River Bend, Unit No. 1 l

cc:

Winston & Strawn Gulf States Utilities ATTN: Mark J. Wetterhahn, Esq.

ATTN: Mr. Philip D. Graham 1400 L Street, N.W.

Vice President, (RBNG)

Washington, D.C. 20005-3502 Post Office Box 220 St. Francisville, Louisiana 70775 Mr. Les England Director - Nuclear Licensing Gulf States Utilities Company St. Francisville, Louisiana 70775 Mr. Philip G. Harris Cajun Electric Power Coop, Inc.

10719 Airline Highway P. O. Box 15540 Baton Rouge, Louisiana 70895 Senior Resident Inspector P. O. Box 1051 St. Francisville, Louisiana 70775 President of West Feliciana Police Jury P. O. Box 1921 St. Francisville, Louisiana 70775 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. J. David McNeill, III William G. Davis, Esq.

Department of Justice i

Attorney General's Office P. O. Box 94095 Baton Rouge, Louisiana 70804-9095 Ms. H. Anne Plettinger 3456 Villa Rose Drive Baton Rouge, Louisiana 70806 l

Administrator i

Louisiana Radiation Protection Division l

P. O. Box 82135 Baton Rouge, Louisiana 70884-2135 l

cc:

Clinton Power Station Unit No. 1 Mr. J. S. Perry Illinois Department Vice President of Nuclear Safety Clinton Power Station Office of Nuclear Facility Safety Post Office Box 678 1035 Outer Park Drive Clinton, Illinois 61727 Springfield, Illinois 62704 Mr. J. A. Miller Mr. Donald Schopfer Manager Nuclear Station Project Manager Engineering Department Sargent & Lundy Engineers Clinton Power Station 55 East Monroe Street Post Office Box 678 Chicago, Illinois 60603 Clinton, Illinois 61727 Mr. Frank A. Spangenberg Sheldon Zabel, Esquire Manager - Licensing and Safety Schiff, Hardin & Waite Clinton Power Station 7200 Sears Tower Post Office Box 678 233 Wacker Drive Mail Code V920 Chicago, Illinois 60506 Clinton, Illinois 61727 Resident Inspector U.S. Nuclear Regulatory Commission RR#3, Box 229 A Clinton, Illinois 61727 Ms. K. K. Berry Licensing Services Manager General Electric Company 175 Curtner Avenue, M/C 382 San Jose, California 95125 Regional Administrator, Region III 799 Roosevelt Road, Building 4 Glen Ellyn, Illinois 60137 Chairman of DeWitt County c/o County Clerk's Office DeWitt County Courthouse Clinton, Illinois 61727 Mr. Robert Neumann Office of Public Counsel State of Illinois Center 100 W. Randolph, Suite 11-300 Chicago, Illinois 60601

ENCLOSURE l

APRIL 27. 1993 l

MEETING ATTENDEES t

NRC ILLINDIS POWER J. Kudrick R. Phares R. Lobell R. Langley W. Long T. Byam D. Pickett l

t l

l i

l l

5 I

l

- l I

i i

I h#9h WW#Us* N mGMT'-

_htwurum w m er emprder--

weemme eg e en

.-.-- -.----1.-.

"