ML20036A379

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 930310-0503.Violation Noted:On 930304,licensee Discovered That EPAs for Both RPS Motor Generators Had Not Been Functionally Tested Per TS 4.8.4.4(a) Since Mar 1991
ML20036A379
Person / Time
Site: Fermi 
Issue date: 05/05/1993
From: Shafer W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20036A378 List:
References
50-341-93-06, 50-341-93-6, NUDOCS 9305110149
Download: ML20036A379 (1)


Text

-

NOTICE OF VIOLATION The Detroit Edison Company Docket No. 50-341 License No. NPF-43 As a result of the inspection conducted from March 10, 1993, through May 3, 1993, a violation of NRC requirements was identified.

In accordance with the

" General Statement of Policy and Procedure for NRC Enforcement Actions,"

10 CFR Part 2, Appendix C (1993), the violation is listed below:

i A.

Technical Specification 4.8.4.4(a) requires that the two Reactor Protection System (RPS) electric power monitoring assemblies (EPA) for each inservice RPS Motor Generator set or alternate power supply shall be demonstrated operable by the performance of a channel functional test.

Contrary to the above, on March 4,1993, in response to NRC concerns, the licensee discovered tnat the EPAs for both of RPS motor generators had not been functionally tested in accordance with Technical Specification 4.8.4.4(a) since March 1991.

This is a Severity Level IV violation (Supplement C). (50-341/93006-02(DRP) 3 DatedagGlenEllyn, Illinois, dCMOpfgA0 w f

this 5 day of May, 1993

g. W. D!Jhhfd, Chief Reactor 7rojects Branch 2 9305110149 930505 PDR ADOCK 05000341 PDR 0