Text
. _ - _ _ _
. _ _ _ _ _ - .
_.
_ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _
.
.
.
gg
31993
- -
o
Docket Nos. 50-295; 50-304
Commonwealth Edison Company
ATTN: Mr. L. O. DelGeorge
Vice President, Nuclear Oversight
and Regulatory Services
Executive Towers West III
1400 Opus Place, Suite 300
Downers Grove, IL 60515
SUBJECT: NRC ENFORCEMENT CONFERENCE, REPORT NUMBER 50-295/93010;
50-304/93010 (DRP)
Dear Mr. DelGeorge:
This refers to an Enforcement Conference conducted by Mr. H. J. Miller and
other members of the Region III staff on April 16, 1993, regarding activities
at the Zion Nuclear Generating Station and to the discussion of our findings
with your staff. We have enclosed a report summarizing the discussion.
You will be notified by separate correspondence of our decision regarding
enforcement action based on the information presented and discussed at the
Enforcement Conference. No response is required until you are notified of the
proposed enforcement action.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosed enforcement conference report will be placed in
the NRC Public Document Room.
We will gladly discuss any questions you may have concerning this Enforcement
Conference.
Sincerely
orgmAt SidWED BY W. L fuciDI
Edward G. Greenman, Director
}DivisionofReactorProjects
Enclosure: Enforcement Conference
Reports No.
50-295/93010(DRP)
50-304/93010(DRP)
See Attached Distribution
See Attached Concurrences
RIII
III
RIII
RIII
RIII
RIII
Lands
Nbe
CMn
DeFayette
Nr
N
'
y
an
g
9305110002 930503 ~
b
ADOCK 05000295
-h
G
jr
_
- - .
,
,
.
,
'
gay
31993
Docket No.
50-547
License No.
Commonwealth Edison Company
ATTN: Mr. L. O. DelGeorge
Vice President, Nuclear Oversight
and Degulatory Services
Executive Towers West III
1400 Opus Place, Suite 300
Downers Grove, IL 60515
SUBJECT:
NRC ENFORCEMENT CONFERENCE, REPORT NUMBER 50-457-93013(DRP)
Dear Mr. DelGeorge,
This refers to an Enforcement Conference conducted by Mr. H. J. Miller and
other members of the Region III staff on April 16, 1993, regarding activities
at the and to the discussion of our findings with your staff. We have
enclosed a report summarizing the discussion.
'
You will be notified by separate correspondence of our decision regarding
enforcement action based on tho information presented and discussed at the
Enforcement Conference. No response is required until you are notified of the
proposed enforcement action.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosed enforcement conference report will be placed in
the NRC Public Document Room.
We will gladly discuss any questions you may have concerning this Enforcement
Conference.
Sincerely,
ORIGINAL SICHED BY W. L NRNEY
Edward G. Greenman, Director
Division of Reactor Projects
Enclosure:
Enforcement Conference
Report No.
See Attached Distribution
RIII
RIII
RIII
R
RIII
RIII
/W
//lb
Oft /0-
UCYc
QBk:
Landsman
F a~ rber
Clayton
DeFayette
Forney
reenman
'
WIV/3
5fh)
h3lf3
$3h3
.
.
Commonwealth Edison Company
2
MAY
31993
cc w/ enclosure:
R. Tuetken, Site Vice President
T. Joyce, Station Manager
S. Kaplan, Regulatory Assurance
Supervisor
D. Farrar, Nuclear Regulatory Services
Manager
OC/LFDCB
Resident Inspectors, Zion, Braidwood,
Byron
R. Hubbard
J. McCaffrey, Chief, Public Utilities
Division
Mayor, City of Zion
Licensing Project Manager, NRR
R. Newmann, Office of Public Counsel,
State of Illinois Center
R. Thompson, Administrator, Wisconsin
Division of Emergency Government
State Liaison Officer
H. J. Miller, RIII
J. Partlow, NRR
J. Lieberman, OE
J. Goldberg, OGC
J. E. Dyer, NRR
bec: PUBLIC