Forwards SE Accepting Util Responses Re Test Plan & Justification for Use of Dynamic Load Factor for Special Handling Device
ML20035H594
Person / Time
Site: Prairie Island  
Issue date: 05/03/1993
From: Gamberoni M
Office of Nuclear Reactor Regulation
To: Richard Anderson
NORTHERN STATES POWER CO.
Shared Package
ML20035H595 List:
References
TAC-M85795, TAC-M85796, NUDOCS 9305060049
Download: ML20035H594 (2)


Text

~-

Docket Nos. 50-282 and 50-306 May 3, 1993 Mr. Roger 0. Anderson, Director Licensing and Management Issues Northern States Power Company 414 Nicollet Hall Minneapolis, Minnesota 55401

Dear Mr. Anderson:

SUBJECT:

RESOLUTION OF TWO UNRESOLVED ITEMS RELATING TO SPECIAL HANDLING DEVICE (TAC HOS. M85795 AND M85796)

On January 25, 1993, Northern States Power Company submitted a response to unresolved items addressed in the Safety Evaluation (SE) dated July 9, 1992, regarding a test plan and justification for use of a dynamic lord factor for a special handling device (lift beam).

Northern States Power Company's r

responses were found to be acceptable. Details of the bases for this conclusion are discussed in the enclosed SE.

This completes our efforts for TAC Nos. M85795 and M85796.

Sincerely, Original signed by Marsha Gamberoni, Project Manager Project Directorate 111-1 Division of Reactor Projects - III/IV/V D

DO O

O 82 P

PDR Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page DISTRIBUTION:

[ Docket: Ei,le' 3 NRC & Local PDRs PDIII-l Reading File JRoe JZwolinski LMarsh 1

MShuttleworth "G *b*r "i 050000 OGC ACRS (10) w

~

EGreenman NWagner i

cc:

Plant Service list j

OFFICE L/L: POI,II-I PM:PDIII-li PD:PDIII-1,

-MShbewokhb14Gamberoh kars NAME n

_7 n

DATE 4/h93 I 3/93 I

4 d 93

/ /

/

cfEhN0 kh/NO 7ES/NO COPY G:\\WPDOCS\\ PRAIRIE \\P185795.LlR ORI~GINAL RECORD COPY j g i

Roger 0. Anderson Prairie Island Nuclear Generating Northern States Power Company Plant CC*

J. E. Silberg, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington DC 20037 Mr. E. L. Watzl, Site General Manager Prairie Island Nuclear Generating Plant Northern States Power ';ompany Route 2 Welch, Minnesota 55089 Lisa R. Tiegel Assistant Attorney General Environmental Protection Division Suite 200 520 Lafayette Road St. Paul, Minnesota 55155 U.S. Nuclear Regulatory Commission Resident Inspector Office 1719 Wakonade Drive East Welch, Minnesota 55089 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road t

Glen Ellyn, Illinois 60137 Mr. Jeff Cole, Auditor / Treasurer Goodhue County Courthouse Red Wing, Minnesota 55066 Kris Sanda, Commissioner Director of Public Service 121 Seventh Place East Suite 200 St. Paul, Minnesota 55101-2145 4

9