ML20035H512

From kanterella
Jump to navigation Jump to search
Forwards Proprietary Amend 27 to ABWR Ssar,Consisting of 11 X 17 Foldout Drawings.Drawings Withheld
ML20035H512
Person / Time
Site: 05200001
Issue date: 04/29/1993
From: Recasha Mitchell
GENERAL ELECTRIC CO.
To: Borchardt R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML19303F604 List:
References
MFN-067-93, MFN-67-93, NUDOCS 9305050177
Download: ML20035H512 (2)


Text

-

h GE Nuclear Energy l

t Gewaif>w C&nn i

m cunne Aveu swun. cA sms i

April 29,1993 MFN No. 067-93 Docket No. STN 52-001 i

Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 3

i Attention:

Richard Borchardt, Acting Director Standardization Project Directorate j

i

Subject:

Submittal of Amendment 27, Proprietary 11x17 Foldout Drawings, j

to GE's ABWR SSAR I

Reference:

Submittal of Amendment 27 to GE's ABWR SSAR, MFN 062-93, dated April 23,1993 l

Enclosed are thirty-four copies of selected sections of Chapter 7,Instmmentation and ControlSystems,.

Chapter 11, Radioactive Waste Management, of the Standard Safety Analysis Report (SSAR) for the l

Advanced Boiling Water Reactor (ABWR).

Revisions for 11x17 foldout drawings are being submitted for the following sections: 73,7.4,7.6,7.7 and I

11.34 and are also identified on the attached Page Change Instruction (s).

l t

Changes to the sections contain information that is designated as General Electric Company

[

proprietary information. These pages are primarily corrections or additions to earlier proprietary i

submittals and the proprietary affidavits under which they were originally issued are applicable to these l

pages.

l Sincerely, j

i 6Q.C."NAW j

R. C. Mitchell, Acting Manager l

Safety & Licensing i

MC-444, (408)925-6948 cc:

R. C. Berglund (GE) hl l

T. E. Murley (NRC)

D. M. Crutchfield (NRC) 1 0

D. J. McGoff (DOE)

I

)

Ob D

F. J. Miraglia, Jr.

(NRC)

C. Posiusny, Jr.

(NRC)

/; g.F t

(N l

K. E. Stahlkopf (EPRI) l N. D. Fletcher (DOE)

}V l.

F. A. Ross (DOE) b vf6{

I n%a%8 9305050177,930429~

1 PDR ADOCK 05200001

-PDR i

L i

i ABWR SSAR l

Amendment 20 - Proprietary Page Change Instruction l

The following pages (11x17 foldout drawings) have been changed, please make the specified changes in your SSAR. Pages are listed as page pairs (front & back). Hold page numbers represent a page that has been changed by Amendment 20.

i REMOVE ADD REMOVE ADD i

PAGE No.

PAGE No.

PAGE No.

PAGE No.

CilAITER 7 CH APTER 7 (con'd) 73-58.4,59 73-58.4,59 Add 7.7-53.11,53.12 7 3-60,61 7 3-60,61 Add 7.7-53.13,53.14 i

73-62,63 7 3-62, 63 Add.

7.7-53.15,53.16 73 44,65 73-64,65 Add 7.7-53.17,53.18 73-66, 67 73-66,67 Add 7.7-53.19,53.20 7 3.68,69 73-68,69 Add 7.7-53.21, 53.22 7 3-70, 71 7 3-70,71 Add 7.7-53.23, 53.24

.1 73-72, 73 7 3-72,73 Add 7.7-53.25, 53.26 Add 7 3-73.1, 73.2 Add 7.7-53.27,53.28 Add 73-733,73,4 Add 7.7-53.29,533 0 Add 7 3-73.5, 73.6 Add 7.7-5331,5332 Add 7 3-73.7, 73.8 Add 7.7-5333,5334-Add 73-73.9,73.10

. Add 7.7-5335,5336 Add 7 3-73.11, 73.12 Add 7.7-5337,5338 Add 7 3-73.13,73.14 Add 7.7-5339,53.40 Add 73-73.15,73.16 Add 7.7-53.41,53.42 Add 73-73.17,73.18 Add 7.7-53.43,53.44 Add 73-73.19,73.20 Add 7.7 53.45,53.46 Add 7 3-73.21,73.22 Add 7.7-53.47,53.48 Add 7.7-53.49,53.50 7.4-19, 20 7.2-19,20 Add 7.7-53.51,53.52 7.4-21, 22 7.4-21,22 Add 7.4-23,23.1 Cil APTER 11 7.6-24, 25 7.6-24,25 7.6-26, 27 7.6-26,27 11.2-14, 15 11.2-14,15 11.2-42,43 11.2-42,43 7.7-42,43 7.7-42,43 11.2-44,45 11.2-44,45 7.7-44, 44.1 7.7-44,44.1 11.2-48,49 11.2-48,49 7.7-44.2,45 7.7-44.2,45 7.7-46,47 7.7-46,47 7.7-48,49 7.7-48,49 7.7-50,51 7.7-50,51 7.7-52,53 7.7-52,53 Add 7.7-53.1, 53.2 i

Add 7.7-53 3,53.4 Add 7.7-53.5, 53.6 Add 7.7-53.7,53.8 Add 7.7-53.9,53.10 April 29,1993

-.