ML20035G826

From kanterella
Jump to navigation Jump to search
Part 21 Rept,Consisting of Error Notice Received from Georgia Inst of Technology Re Incorrect Answers Which May Not Be Apparent or Job Aborts in Gtstrudl Computer Code. Listed Vendors Not Notified Due to Unknown Addresses
ML20035G826
Person / Time
Site: Neely Research Reactor
Issue date: 04/01/1993
From: Keithley J
BOEING CO.
To:
NRC
References
REF-PT21-93 NUDOCS 9304300072
Download: ML20035G826 (4)


Text

.

Boeing Computer Services PO Bcx 24346 5eame. AA %44-0346 April 1,1993 G-1151-JMK-93-146 NRC Operations Center United States Nuclear Regulatory Commission Washington, D.C. 20555

Reference:

a)

Boeing Letter G-1551-RSO-365 dated August 31,1992; R.

S. Orr to the NRC Operations Center b)

NRC Letter Docket No. 99901227 dated August 12,1992; L J. Norrholm to R. S. Orr;

Subject:

Response to 10 CFR 1

21 Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is

~

sending the NRC the attached error notice (s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:

Reactor Controls, Inc.

Echo Energy Consultants, Inc.

Nuclear Applications and Systems Analysis Company (Japan)

Nuclear Power Services URS/ John A. Blume & Associates Error notices have been sent to our other former customers.

Very truly yours, 1

F J. M. Keithley Nuclear Administrator I

G-1151 M/S 7F-06

{

(206) 865-4438 Attachment (s):

GTICES Program Error Reports 93.09 and 93.10 290057 fpeg 9ao4aooon 9204o1

/}f0 PDR ADOCK 0500o160 1

i S

PDR v

i

GTISL (GTICES) PRCGRAM REPORT FORM

$,O f j

GPRT No.:

t DATE:

7-21-7>

FROM: GTICES SYS'IEMS IABORA'IORY GIDRGIA INSTI'IUTE OF TEOCOI.OGY ATIRiTA, GEORGIA 30332-0355 1'l SEVERITY LEVEL:

d URGUTI Problem results in incorrect answers which may not be apparent er._Db. aborts and cannot be recovered within the session or job.

SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion. of a

particular user's task.

MIrCR Problem can be worked around or problem poses high frustration factor.

IhTORMATIVE Documentation

error, program usage-tip, user inconveniences.

DATE PROBLEM CQiFIRMED 3~73'f$

tate renr2CATIm Sarr

3. Ir-9 3 CowrtRS A//

OPER. SYSTEM

///

GTISL aASIC SYSTEM vERSIm A//

GTICES PRODUCT NAME 675DIBSL vERSIm 9%Of & _fw n TARGET RELEASE FOR CORRECTION fY,O/

l (GPRF - 12/B7) Rev. J

6t'nl-ff 13 U /]

^

RAGIDITY MATRIX INPUT FOR IPSL, IPSQ, AND TRANS3D ELEMENTS Incorrect results (displacements, stresses, reactions, frequencies,...etc) will result if a RIGIDITY MATRIX is used to specify the material properties for the IPSL, IPSQ, and TRANS3D elements.

Workaround:

Use the IPLS element instead of the IPSL.

Use the IPQS element instead of the IPSQ.

Applicable Sections in the Documentation:

RIGIDITY MATRIX input - Section 2.3.5.2, ELEMENT PROPERTIES Command Table 2.3.I - GTSTRUDL Finite Element Dictionary i

l l

i i

a n

y -

GTISL (GTICES) PRCGRAM REPORT TORM i

GPRT No.:

h3, /O DATE: 1 -2.2 -9 ?

FROM: GTICES SYSTEMS IABORAKIRY GIDRGIA INSTI'IUTE OF TEOCCIOGY ATLANTA, GEDRGIA 30332-0355 SEVERITY II/EL:

/ URGDIT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job..

SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a

particular user's task.

MItoR Problem can be worked around or problem poses high frustration factor.

I!7 FORMATIVE Documentation

error, program usage
tip, user inconveriiences.

DATE PROBLEM CONTIRMED

.3 ?]

DATE toTIFICATIai SDIT 3 - U-73 CCmurERS M OPER. SYSTEM ///

GTIGL BASIC SYSTEM VERSICN ///

GTICES PROOuCT raME 5TsTgvoL VERSIai AY versiu s m e u.'eus P3.0 /

TARGET RELEASE IVR CORRECTICN [J.o /

(GPRr - 12/87) Rev. J