ML20035F861
| ML20035F861 | |
| Person / Time | |
|---|---|
| Issue date: | 04/21/1993 |
| From: | Hauber R NRC OFFICE OF INTERNATIONAL PROGRAMS (OIP) |
| To: | |
| References | |
| NUDOCS 9304220350 | |
| Download: ML20035F861 (1) | |
Text
EXPORT LICENSE
_ w_wn-----------
( NRC FORM 250 (C @p ~1 NRC LICENSE NO.
9
. w,-.n W-I y THIS12CENSEEXNRES 31 December 1995 i
I Enitch States of America XSNM02596 i
W Amendment No. 02 j
Nuclear Regulatory Commission Pursuant to the Atomic E nergy Act of 1954, as amended,ard the Energy to the licensee authorizing the export of the materials and/or production 1 l Reorganization Act of 1974 ard the regulations of the Nuclear Regulatory or utilitation faci:ities listed below, subject to the terms ard conditions i Comm ssion issued pursuant thereto, and in retsance on statements and herein.
representations heretofore made by the licensee, a license is hereby issued h
LICE NS E E ULTIM ATE CONSIGNEE IN FOREIGN COUNTRY 4
@:s NAME Braunkohle Transport USA, Inc.
Grohnde Nuclear Power Plant, Unit 1 NAME le
!d 4193 Crescent Drive, Suite E AcoRESS ADDRESS Grohnde, Hamelin
{
St. Louis, MO 63129 Fedecal Republic of Germany f
Attn:
Robert L. Grant
/(
u f
(Fuel for Grohnde Nuclear Power Plant d
Unit 1)
(ERMEDI ATE CONSIGNEE IN FOREIGN COUNTRY OTHE R PARTIES TO EXPORT
(
Fragema PREUSSENELEKTRA
- a Attn
Service Affaires Postfach 48-49
{h 0 **** B/P. 83 3000 Hanover 1 F-69398 Lyon Cedex 3, France Federal Republic of Germany y
(Utility Owner) i British Nuclear Fuels Limited g * "*" Springfield Works f
U.S. Department of Energy h
Salwick, Preston, Lancashire, England Portsmouth Gaseous Diffusion Plant
,g United Kingdom c/o Martin Marietta Energy Systems Pikteon, OH 45661 g
(Convorcinn and Fabricationi (Sonnlier)
% APPLICANT'S REF. NO.
[ tp, dtd, 4/j/gg COUNTRY OF ULTIM ATE DESTINATION ppdopp j poqqh]jp ny k
OUANTITY DESCRIPTION OF MATERIALS OR F ACILITIES Germany s@.
The licensee is authorized to export 333.38 kilograms uranium-235, contained in 8,995.0 kilograms uranium, enriched to 4.0 w/o maximum.
4 The license is amended to: 1) increase the quantity of material authorized for export from 26.2 kilograms uranium-235/1,110.0 kilograms uranium to
?
333.38 kilograms uranium-235/8,995.0 kilograms uranium (an increase of 307.18 i
kilograms uranium-235/7,885.0 kilograms uranium); 2) increase enrichment from i
2.3 w/o to 4.0 w/o maximum; 3) delete Siemens Aktiengese11schaft as inter-lc gg mediate consignee; 4) add Fragema and British Nuclear Fuels Limited as inter-f{%;
mediate consignees for conversion and fabrication; and 5) change licensee's address.
All other conditions remain unchanged.
S/////////////// /////////////////////////////////END//////////////////////////////////////////
l k
6 N;ither this licenza nor any right under this license shall be assigned or S AUTH MlZED RC REPRESENTATIVE
- otherwise transferred in violation of the provisions of the Atomic Energy
' l Act of 1954, as amended and the Energy Floorganization Act of 1974 Ronald D. Hauber, Assistant Director
)yl the Atomic Energy Act of 1954, as amended ard to all of the other provi.
This nicense is subject to the right of recapture or controi by section ios of For Exports, Security, and Safety Cooperation OffjCe of International Programs sions of said Acts, now or hereafter in effect sad to all valid rules ard s reguistions of the nucwar Regui. tory commin.on.
g y
KJ3 42g3g 930421 d\\
,,,,,,,,,,,,c, j
mmmm,m___,,m,,,
XSNM-2596 PDR EXPORT LICENSE: