Gil 0 91993,
Docket No. 50-309
Mr. Charles D. Frizzle
President
Maine Yankee Atomic Power Company
-
83 Edison Drive
Augusta, Maine 04336
Dear Mr. Frizzle:
Subject: NRC INSPECTION NO. 50-309/93-06
An announced safety inspection of the radiation protection program at your facility was
conducted by Mr. J. Furia of this office on March 29 - Apn.' ',1993. The inspection
findings were discussed with members of your staff at the cor.
sion of the inspection on
April 2,1993.
Areas examined during this inspection are important to health and safety and included the
radiation protection program, as described in the NRC Region I Inspection Report which is
enclosed with this letter. Within these areas, the inspection consisted of selective
examinations of procedures and representative records, interviews with personnel, and
observations by the inspector.
Early implementation by your staff of the new Title 10, Code of Federal Regulations (CFR)
Part 20 on April 1,1993 is a notable accomplishment. Strong performance in dosimetry was
also observed.
Your cooperation with us in this matter is appreciated. No reply to this letter is lequired.
Sincerely,
.
W MISiOMdBW
James H.Joyner
James H. Joyner, Chief
Facilities Radiological Safety
and Safeguards Branch
Division of Radiation Safety
and Safeguards
9304200001 930409
ADOCK 05000309
G
t\\
omew.RecoRDCOPY
- y
pg
g q-
L
<
\\S
h
'#
wa
--
. . .
.
_ _ _ _ _ _ _ _ _ _ _ _ _
. _ _ - _ _ _
.
.
.
-
.
.
Maine Yankee Atomic
2
,n
1 9 1993
Power Company
Enclosure: NRC Region I Inspection Repon No. 50-309/934)6
cc w/ encl:
G. Leitch, Vice President, Operations
P. L. Anderson, Project Manager (Yankee Atomic Electric Company)
R. W. Blackmore, Plant Manager
J. A. Ritsher, Attorney (Ropes and Gray)
P. Dostie, State Nuclear Safety Inspector
Peter Brann, Assistant Attorney General
U. Vanags, Maine State Planning Office
C. Brinkman, Combustion Engineering, Inc.
First Selectmen of Wiscasset
Maine State Planning Officer
Public Document Roore (PDR)
Iscal Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
K. Abraham, PAO (2)
NRC Resident InsIrctor
l
OFFICIAL RECORD COPY
____
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .
_ _ . .
__
.
.
IEii 0 9199#
Maine Yankee Atomic
3
Power Company
bec w/ encl:
Region I Docket Room (with concurrences and IFS Forms)
DRS/EB SALP Coordinator
J. Linville, DRP
W. I2zarus, DRP
C. Marschall, SRI - Maine Yankee (w/ concurrences and IFS Forms)
H. Eichenholz, SRI - Vermont Yankee
V. McCree, OEDO
E. Trottier, LPM, NRR
W. Butler, NRR
DRSS RI
R s:RI
5:RI
f,
JFuria
' Pas ak
Joyner
4/f/93
4 ' 93
4$/93
OFFICIAL RECORD COPY
..