1 Director, Office of Resource Management March Monthly Operating Report Page 1 ATTACEMENT I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50/395 UNIT V. C. SUMMER I i
i DATE 4/ 1/93 CORPLETED BY J. W. HALTIWANGER TELEPHONE (803) 345-4297
)
l MARCH 1993 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1.
869 17.
-8 2.
860 18.
-8 l
1 3.
854 19.
-8 4.
839 20.
-8 5.
783 21.
-8 l
6.
-17 22.
-8 7.
-33 23.
-7 j
8.
-21 24.
-7 9.
-12 25.
-7 10.
-9 26.
-7 11.
-8 27.
-7 12.
-9 28.
-7 13.
-8 29.
-7 14.
-9 30.
-7 i
15.
-9 31.
-7 16.
-8 9304i120187 930408 PDR ADOCK 05000395 R
PDR ww
i Director, Office of Resource Management March Monthly Operating Report Page 2 ATTACHMENT II OPERATING DATA REPORT DOCKET NO.
50/395 UNIT V.
C. SUMMER I DATE 4/ 1/93 COMPLETED BY J. W. HALTIWANGER TELEPHONE (803) 345-4297 OPERATING STATUS
- 1. Reporting Period:
March 1993 Gross Hours in Reporting Period:
744
- 2. Currently Authorized Power Level (MWt):
2775 Max. Depend. Capacity (MWe-Net):
885 Design Electrical Rating (MWe-Net):
900
- 3. Power Level to Which Restricted (If Any)(MWe-Net): N/A
- 4. Reasons for Restrictions: N/A l
~
THIS MONTH YR TO DATE CUMULATIVE
- 5. Number of Hours Reactor Critical 122.4 1499.0 64676.7
- 6. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
- 7. Bours Generator on Line 121.7 1432.2 63452.5
- 8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 9. Gross Thermal Energy Generated (MWH) 315170 3856463 165899221 i
- 10. Gross Electrical Energy (MWH) 105940 1292650 55018409
- 11. Net Electrical Energy Generated (MWH) 89830 1223862 52286347
- 12. Reactor Service Factor 16.5 69.4 79.8
- 13. Reactor Availability Factor 16.5 69.4 79.8
- 14. Unit Service Factor 16.4 66.3 78.3
- 15. Unit Availability Factor 16.4 66.3 78.3
- 16. Unit Capacity Factor (Using MDC) 13.6 64.0 72.9
- 17. Unit Capacity Factor (Design MWe) 13.4 63.0 71.7 l
- 18. Unit Forced Outage Rate 0.0 6.9 5.9
- 19. Shutdowns Scheduled Over Next 6 Months (Type, Date & Duration of Each):
N/A
- 20. If Shut Down at End of Report Period, Estimated Date of Startup:
MAY 9,1993
- 21. Units in Test Status (Prior to Commercial Operation): N/A I
i l
l
I I
i l
l i
i l
Director, Office of Resource Management March Monthly Operating Report l
Page 3 ATTACHMENT III UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
50/395 UNIT V. C. SUMNER I DATE 4/ 1/93 COMPLETED BY J. W. HALTIWANGER-TELEPHONE (803) 345-4297 MARCH 1993 NO.
DATE TYPE DURATION REASON METHOD CORRECTIVE ACTION / COMMENTS 2 930306 S
622.3 C
1 SEVENTH REFUELING 1.0 REASON l
A: Equipment Failure l'
C: Refueling B: Maintenance or Test D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error H: Other (Explain) l 2.0 METHOD l
1: Manual 2: Manual Scram j
3: Automatic Scram i
t 4* Continuation (Use initial Date)
I 5: Power Reduction (Duration 0.0)
- 9. Other (Explain) l l
-,... ~ - - -
Director, Office of Resource Management March Monthly Operating Report Page 4 ATTACHMENT IV NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE DOCKET N0.
50/395 UNIT V. C. SUMMER I DATE 4/1/93 COMPLETED BY J. W. HALTIWANGER
)
TELEPHONE (803) 345-4297 1
MARCH 1993 V. C. Summer Nuclear Station, Unit I was in end-of-cycle power coastdown at the beginning of March. Power had decreased to approximately 95 percent on the 4th, at which time power was reduced to less than 87 percent for main steam safety valve testing. Final power reduction began on March 6th.
The plant was taken off line at 0140 and entered Mode 3 at 0225 on March 6th.