Ack Receipt of Response to GL 92-04, Resolution of Issues Re Reactor Vessel Water Level Instrumentation in Bwrs. NRC Finds Listed Actions Acceptable
ML20035C614
Person / Time
Site: FitzPatrick 
Issue date: 04/05/1993
From: Mccabe B
Office of Nuclear Reactor Regulation
To: Ralph Beedle
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
References
GL-92-04, GL-92-4, TAC-M84280, NUDOCS 9304080181
Download: ML20035C614 (4)


Text

y w.

[

5 UNITED STATES

-[ k,i 1 j NUCLEAR REGULATORY COMMISSION

gg

/

- j WASHINGTON. D.C. 20555-0001

'%I w'

April 5, 1993 Docket No. 50-333 Mr. Ralph E. Beedle Executive Vice President, Nuclear Generation Power Authority of the State of New York 123 Main Street White Plains, New York 10601

Dear Mr. Beedle:

SUBJECT:

RESPONSE TO GENERIC LETTER 92-04, " RESOLUTION OF THE ISSUES RELATED TO REACTOR VESSE!. WATER LEVEL INSTRUMENTATION IN BOILING WATER REACTORS" - JAMES A. FITZPATRICK NUCLEAR POWER PLANT (TAC NO. M84280)

This letter acknowledges receipt of your response to Generic Letter (GL) 92-04, dated September 29, 1992.

GL 92-04 was issued by letter dated 1

August 19, 1992, to all operating Boiling Water Reactor (BWR) Licensees.

GL 92-04 requested licensees to promptly assess the impact on their facilities l

of potentially erroneous level indication due to noncondensible gases, and to implement compensatory measures and long-term corrective actions as necessary.

We find acceptable:

l l

(1)

The Power Authority of the State of New York's (PASNY) review and acceptance of the BWR Owners Group (BWROG) generic analysis as being l

applicable to the FitzPatrick plant.

(2)

PASNY's endorsement of the BWROG commitment, outlined in its letter dated August 12, 1992, regarding schedule and plans for actions to address postulated errors in BWR water level instrumentation.

(3)

PASNY's implementation of plant-specific guidance to address all of the concerns identified in the BWR0G's Emergency Procedures Committee guidance letter dated August 19, 1992. This letter provides guidance for operator action in the event of level indication errors due to non-condensible gases during reactor pressure vessel (RPV) depressurization.

We also understand that you have sensitized your operators to these potential errors consistent with the BWROG guidance.

(4)

PASNY's commitment to implement modifications, if deemed necessary, to assure that the water level instrumentation is of high functional f

reliability.

Contrary to the schedule provided in your September 29, f

1992, letter, we request that you provide the NRC with a description of

]

9304000181 930405

  • v DR ADOCK 0500 3

-anr s

,e 3

yz 4, -

c

..-~

i Mr. Ralph E. Beedle April 5,1993 the long-term corrective actions that you plan to implement at the FitzPatrick plant as well as an implementation schedule by July 30, c

1993.

The BWROG has approved refined operator guidance developed by the Emergency Procedures Committee for response to instrument errors due to noncondensible l

gases.

This guidance was sent to your staff on October 16, 1992. We feel i

that this guidance provides appropriate information for operators to adequately identify and deal with potentially inaccurate RPV level 3

instrumentation, and expect that this or equivalent guidance, has been incorporated into your station operations.

t j

Should you have any questions, please contact me at (301) 504-1423.

1 Sincerely, A ut1:

0 Brian C. McCabe, Project Manager Project Directorate I-l Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation i

cc:

See next page

l l

I i

i I

f l

1 I

I

1 Mr. Ralph E. Beedle James A. FitzPatrick Nuclear Power Authority of the State of New York Power Plant cc:

i Mr. Gerald C. Goldstein Ms, Donna Ross Assistant General Counsel New York. State Energi Office Power Authority of the State 2 Empire State Plaza of New York 16th Floor 1633 Broadway Albany, New York 12223 3

New York, New York 10019 Resident Inspector's Office U. S. Nuclear Regulatory Commission Post Office Box 136

~

Lycoming, New York 13093 r

Mr. Harry P. Salmon, Jr.

Resident Manager James A. FitzPatrick Nuclear Power Plant Post Office Box 41 Lycoming, New York 13093 1

Mr. J. A. Gray, Jr.

I Director Nuclear Licensing - BWR i

Power Authority of the State t

of New York 123 Main Street I

White Plains, New York 10601 l

i I

Supervisor Town of Scriba Route 8, Box 382 a

l Oswego, New York 13126 Mr. John C. Brons, President i

Power Authority of the State of New York 123 Main Street i

White Plains, New York 10601 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 5

120 Broadway 1

New York, New York 10271 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road l

King of Prussia, Pennsylvania 19406 j

f 8

-r--

~,

Mr. Ralph E. Beedle April 5,1993 the long-term corrective actions that you plan to implement at the FitzPatrick plant as well as an implementation schedule by July 30, 1993.

The BWROG has approved refined operator guidance developed by the Emergency Procedures Committee for response to instrument errors due to noncondensible gases. This guidance was sent to your staff on October 16, 1992. We feel.

l that this guidance provides appropriate information for operators to adequately identify and deal with potentially inaccurate RPV level instrumentation, and expect that this or equivalent guidance, has been incorporated into your station operations.

Should you have any questions, please contact me at (301) 504-1423.

l Sincerely, Original Signed By:

Brian C. McCabe, Project Manager Project Directorate I-l Division of Reactor Projects - I/II j

Office of Nuclear Reactor Regulation cc: See next page t

]

DISTRIBUTION:

Docket File l

NRC & Local PDRs j

PDI-l Reading i

SVarga JCalvo RACapra CVogan BMcCabe

)

OGC ACRS (10) i JClifford, 13/E/16 TQuay, 13/E/16 RJones, 8/E/23 l

CCowgill, RGN-1 Plant File

  • See previous concurrence DUICE PDI-1:LA PDI-1:PMM,o SRXB PDI-1:D BMcCabefak
  • RJones RACapraW KAME CVogan r

/,iL/93 M/4[/93 03/19/93 04 c6/93

/ /

1

/

DATE 0FFICIAL RECORD COPY j

FILENAME: G:\\ FIT 84280.LTR j

.-w---

- - - -