Docket No. 50-440 MEMORANDUM FOR:

Gary.G. Zech, Chief Performance and Quality Evaluation Branch Division of Reactor. Inspection and Licensee Performance-FROM:

John N. Hannon, Director Project Directorate III-3 Division of Reactor Projects III/IV/V

SUBJECT:

PERRY PERFORMANCE EVALUATION TREE

~

Recent operating experience at Perry including failed fuel, MSIV leakage problems and a service water pipe rupture, in addition to management weaknesses, suggest a decline in performance. My staff has been discussing the possibility of completing a performance evaluation tree for Perry in support of the June '93 Senior Management Meeting. We understand that this effort generally requires 3 people full time for over a week and may not fit into your schedule to complete in time for the pre-brief on April 16, 1993.

We are prepared to provide Beth Wetzel to support your efforts to meet an April 16 deadline, or at least in time to publish in the-SMM book in mid-May..

Beth will be in touch with the Region III performance evaluator to work out the details.

ORIGINAL SIGNED BY:

John N. Hannon, Director Project Directorate III-3 Division of Reactor Projects III/IV/V cc:

J. Zwolinski E. Greenman, RIII DISTRIBUTION IDocketjFile: 7 NRC & Local PDRs JRoe JZwolinski JHannon f{fg-2L,;%

MRushbrook t~e p

,_' re e m p.

BWetzel 0GC

-,i%

ACRS (10)

Region III, DRP l W I1 0FFICE PDIUbdA:DRPW PDIII-3:PE:DRPWi PDIM: PD:DRPW NAME MRuYhbrook BWetzel/baw/ bah JHannop DATE

/[/93-Y/[/93 M/(/93 0FFICIAL RECORD

/

DOCUMENT NAME:

g:\\ perry \\perzech.mem h

.(0\\

DOhKOhohk4o PDR 4