ML20035B847

From kanterella
Jump to navigation Jump to search
Westinghouse Fuel Assembly Reconstitution Evaluation Methodology for Vogtle Unit 1 Cycle 5
ML20035B847
Person / Time
Site: Vogtle  
Issue date: 03/31/1993
From: Novendstern E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
Shared Package
ML20035B841 List:
References
NUDOCS 9304050180
Download: ML20035B847 (19)


Text

.

e m

WESTINGHOUSE FUEL ASSEMBLY RECONSTITUTION EVALUATION hETHODOLOGY FOR VOGTLE UNIT 1 CYCLE 5 March 1993 Edited by:

S. L. Davidson Approved:

-h E. H. Novendstem, Manager Fuel Analysis & Licensing 4

9 Westinghouse Electric Corporation Nuclear Manufacturing Divisions W

P. O. Box 355 Pittsburgh, Pennsylvania 15230

=

9304050100 930329 PDR ADOCK 05000424 P

PDR

~

i ABSTRACT i

This document provides the evaluation methodology that was used for Vogtle Unit 1 Cycle 5 to analyze i

fuel assembly reconstitution. This document complements the NRC approved " Westinghouse Reload l

Safety Evaluation Methodology" topical report, WCAP-9272-P-A, that focuses on the analytical and safety aspects of the reload design activity and is consistent with the methodology in WCAP-13060-P,

" Westinghouse Fuel Assembly Reconstitution Evaluation Methodology," currently under NRC review, I

i i

l f

i I

i 4

i i

4 l

l Rev 0300/93 9.15am I

I

1 I

i

/

TABLE OF CONTENTS l

i Section Title Page

]

l 1.0 lhTRODUCTION.........

1 2.0 MECHANICAL DESIGN METHODOLOGY...

4 2.1 Fuel Assembly Evaluation Methodology................................. 4 2.2. Methodology Discussion 4

2.3 Fuel Rod Evaluation Methodology..................................... 5 1

3. 0 NUCLEAR DESIGN hETHODOLOGY...........

8 3.1 Evaluation Methodology............................................ 8 3.2 Methodology Discussion.........

8 4.0 THERMAL AND HYDRAULIC DESIGN METHODOLOGY....................... 9 4.1 Evalu ation Methodology........................................... 9 4.2 Methodology Discussion........................................... 9 1

i 5.0 NON-LOCA METHO DOLOGY........................................... 11 5.1 Non-LOCA Evaluation Methodology.................................. 11 5.2 Methodology Discussion........................................... 12 6.0 LOCA METHODOLOGY............................................... 13 6.1 LOCA Evaluation Methodology...................................... 13 6.2 Methodology Discussion........................................... 13

7.0 REFERENCES

....................................................... 15 Rev 03/29/73 9:15arn II P

f

LIST OF FIGURES Figure No.

Ficure Pace Figure 1 Reconstituted Core loading Pattern.......

2 Figure 2 Actual Location'of Filler Rod within Reconstituted Assembly 5F22......

3 Figure 3 Typical Fuel Rod and Replacement Rod 6

Figure 4 17x17 Feel Assembly Outline........

..-7 f

r 1

I h

F t

h

(

Rev 03!20S3 9:15am Ili j

i f

i t

1.0 INTRODUCTION

During the current Vogtle-1 refueling outage, one damaged fuel rod was identified in fuel assembly 5F22, scheduled to be reloaded into the Vogtle 1 Cycle 5 core. The affected assembly location and fuel rod are shown in Figures 1 and 2. The mechanical features of the Vogtle 1 fuel assemblies permit the replacement of the damaged fuel rods with filler rods. This report describes the methodology that wac employed to evaluate all applicable design criteria associated with reconstitution in the Vogtle Unit 1 Cycle 5 core that used a solid filler rod in place of the damaged uranium fuel rod.

Based on evaluations of the safety aspects of reconstitution, performed by the functional disciplines (Mechanical, Thermal-Hydraulic, Fuel Rod Performance, Nuclear, LOCA and non-LOCA) using NRC-approved methodologies, it was demonstrated that the effects of fuel assembly reconstitution on the Vogtle Unit 1 Cycle 5 core performance are minimal. These evaluations / analyses were performed using the methodology described in this report for the reconstituted fuel assembly in the Vogtle Unit 1 Cycle 5 core.

The Cycle 5 methodology is identical to that methodology described in WCAP 13060-P and complements the NRC-appmved, " Reload Safety Evaluation Methodology," WCAP-9272-P-A.

Rev 0309/93 9.15arn 1

i ll

~.

l Figure I l

Reconstituted Core leading Panem R

P N-W

' L.

K.

J.

H C.

F. -

E.

D C

8 A

i i

58 SA 5A SA SA SA 58 -

1 l

i 2

88 7A 7A 7A 78 7A 7A 7A 48 2

2 2

7A 75 7A 3

7A SA 7A.

3 7A 75-7A 2

3 i

68 79 SA SA 7A S8 SA 88 7A SA SA 75 68 4

i 58 7A 7A SA 73 SA 78 SA 79 SA 75 SA 7A 7A 58

-5 I

i SA 7A 31 7A SA SA SA 75 SA SA

'SA 7A 3

7A SA.

-8 1

SA 7A 7A GB 75 SA 75 SA 75 75 GB.

7A 7A SA !

90s SA 73 SA SA

'SA 75 SA 3

SA 70

'SA SA SA 73 5A

-8 i

5A 7A 7A GB '

75 SA 75 SA 75 SA 75

.09 7A 7A '-

SA

-9 SA 7A 3

7A SA SA SA 75 SA SA SA 7A

~3 7A SA

- 10 SB 7A 7A-SA 75 SA 75 SA 75 SA 75 SA-7A 7A 58

- 11 l

3 80 75 SA SA 7A N

SA B

7A SA SA 75 GB 12-l i

2 7A 75 7A 3-7A SA 7A 3

7A 73 7A 2

13 i

d -

1 G3 7A 7A 7A-75 7A 7A

-7A 5

2 14 SB SA SA 5A 5A SA SB 15 1

~

Oe LEGEND :

R Region Identifier 2

I4 cation of Reconstituted Fuel Assembly

f Figure '

Actual Location of Filler Rod Within Reconstituted Assembly 5F22 Y CORNER FACE 4 OPONMLKJ lHGFEDCBA 1

2 X

X X

3 X

X 4

5 i

X X

X X

X e

7 8

X X e X

X X

s >= '

> = =

10 11-X X

X X

X 12 13 X

X 14 X

X X

15 16 17 r

FACE 2 TOP VIEW g Stainless Steel Repiscenent Fin Location j

Rev 03/29S3 9:15arn 3

l 2.0 5tECIIANICAL DESIGN htETIIODOLOGY j

t 2.1 Fuel Assembly Evaluation hiethodology The Vogtle Unit 1 Cycle 5 fuel assemblies are designed to perform satisfactorily under design loads throughout their lifetime. The loads, deflections and stresses resulting from the combined effects of normal operation and faulted condition loads were considered in the fuel assembly evaluation. The effect of replacement rods on the fuel assembly's mechanical properties and loads were assessed to insure that the reconstituted assembly met all the established criteria. The introduction of the one replacement rod does not adversely impact the performance of the existing fuel assemblies.

All of the design criteria specified in Standard Review Plant (SRP) 4.2 (Reference 1) were reviewed. From a mechanical design and fuel coolability viewpoint, the mechanical criteria affected are the following-I i

o Fuel Assembly Holddown Forces, and l

t o

Fuel Assembly Structural Response to Seismic /LOCA Loads.

i The design basis for the fuel assembly holddown forces requires that the fuel assembly will not lift due f

to flow during normal operating conditions. The basis for the fuel assembly structural response to seismic /LOCA loads is the design requirements for combined seismic and LOCA loads per Appendix A to SRP 4.2.

s The methodology used in the evaluation of these criteria and the results are funher discussed in the following two sections.

I J

2.2. hiethodology Discussion i

a Fuel Assembly Holddown Force The replacement rod shown in Figure 3 is a solid cylinder of stainless steel material. The replacement filler rod like a fuel rod is supported by the grid springs and dimples to maintain rod-to-rod spacing. A L

schematic of this fuel assembly containing the filler rod is shown in Figure 4.

l Rev 0109S3 9:15am 4

f s

t

Replacement filler rods have the same outside diameter and similar design configuration as a fuel rod.

These rods also displace essentially the same volume of coolant as a fuel rod when submerged in a reactor core. Thus, the assembly lift and buoyancy forces are en ~ "ed. However, the weight of a replacement rod is less than a fuel rod. The lower weight of a replact.r t.

3 escits in an increase in the net upward

~

force on the fuel assembly. The increase in the net upward force is well within the existing holddown spnng force design margin. The fuel assembly holddown spring design is adequate to offset the net upward force increase due to fuel assembly reconstitution. The design requirement of preventing fuel assembly lift off due to an increr.se in the net upward force during normal operating conditions is met.

Fuel Assembly Structural Response to Seismic /LOCA Imads l

The effects of seismic /LOCA faulted condition transients on the reconstituted fuel assembly were assessed.

The interactions between two fuel assembly designs, reconsututed and non-reconstituted, were evaluated l

using the NRC-approved methodology and analytical procedures given in Reference 2.

l The stainless steel filler red has material characteristics / properties which actually strengthen the assem'ofy structure. The filler rod does not affect the dynamic propenies and impact strength of the grids. Based on the seismic /LOCA loads study discussed in WCAP 13060 P (Reference 10), the reconstituted fuel assembly loaded in the Cycle 5 core will not change the conclusions of the fuel assembly suuctural response found in the Vogtle updated Final Safety Analysis Report (FSAR).

2.3 Fue! Rod Evaluation Methodology As part of the Westinghouse reload design methods described in Reference 3, cycle-specific fuel rod design evaluations are performed using NRC-approved Westinghouse fuel performance models (Reference 7).

Fuel rod design criteria addressed by Westinghouse (References 4,5, and 6) in these cycle-specific evaluations are not significantly impacted by fuel assembly reconstitution. The only effect of fuel assembly reconstiarion on the remaining fuel rods is a very slight increase in the core average linear heat generation rate resulting from the replacement of fuel rods with inert rods. This slight increase has been evaluated and has been found to have a negligible effect with respect to fuel performance analyses as performed for Vogtle Unit 1 Cycle 5. The fuel rod design criteria are met for all remaining fuel rods in the Cycle 5 core.

Rev 03/29/93 9-15am 5

. +

I Figure 3 Typical Fuel Rod and Replacement Rod I

i s

7 l

A 7 CND Sh,ll

'[

/

/0\\

A t

..j 6

1 l

': 3 l

ks N

i I

- m u t.a. =.w :r :..:

ir i

n ruc. =ce.ct i

l

.b

% ct4s

,8 mm I

n n

+

1 5

\\

  • =~

' W sem> cu u

l

)

l Replacement Rod Fuel Rod I

'l

^!

2-e i

B i

e i

f 3

'i

Figure 4 1

17x17 Fuel Assembly Outline a

,W.e Mh l

e e w "~e

--4 >-c>=c>- c;d a,

- ---. ~ _

t w

m.

--TOP NOZZII

. W~CI.c~cp

~

~-

'g-<c % e -j;2""'

PNTOP GRID

, TOP vitw 1

t t.

4 k

i

- F'UEL ROD I

I I

I I

I I

I l

l l

l l

l l

l 1

l l

l l

l l

1 I

l l

l l

l l

II I

l l

l l

l l

l l

l l

l l

l l

l l

1 1

I I

I I

I I

I I

I I

I I

I I

I I

i 6

I I

I l

l l

l l

l l

l l

l l

l I

I t

, m<

< < m, m,,,

-BOTTOM GRID l

umnismnn

.......<.s......-

r eeee*

BOTTOM N0ZZLE d

M.........

t i

Rev 03CIM 2Qm 7

1

.]

1 e

0

3.0 NUCLEAR DESIGN METHODOLOGY 3.1 Evaluation Methodology j

ne nuclear design evalsation was performed using NRC-approved codes and methods which are consistent with ihe fuel assembly reconstitution evaluatica methodology currently under NRC review, Reference 10. A design evaluation, consistent with Reference 3, was performed on the Cycle 5 loading pattern containing the reconstituted fuel assembly to ensure that the design criteria for the reload are met Fuel assembly reconstitution affects reactivity and local peaking due to the redistribution of power within the assembly. The effects of fuel reconstitution were evaluated for Cycle 5 by reviewing a list of nuclear design and key safety parameters which are based on the bounding values found in the updated FSAR.

The Cycle 5 specific evaluation used standard design methods to confirm the applicability of key safety parameters.

i e

3.2 Methodology Discussion i

The effects of the reconstituted fuel assembly, which had the damaged fuel rod replaced with a stainless steel filler rod, were analyzed. De Cycle 5 specific core location for the reconstituted fuel assembly was f

evaluated to assess the impact on reactivity and local peaking. The nuclear design models for this evaluation were generated using current NRC-approved design methodology. Based on the results of these nuclear design models, each key safety parameter was evaluated consistent with the requirements in Reference 3.

It was confirmed that the nuclear design and key safety criteria were met for the

+

reconstituted Cycle 5 core with one filler rod.

j a

r

'i i

i

=

i I

i l

I l

Rev 03/29.93 9:15am 8

l 1

f a

.l

l l

4.0 THERMAL AND HYDRAULIC DESIGN METHODOLOGY 4.1 Evaluation Methodology

\\

The thermal-hydraulic design evaluation of fuel assembly reconstitution for Vogtle Unit I was performed j

in accordance with the evaluation process of design criteria spec.fied in Reference 3, using h7C approved I

codes and methods which is consistent with the fuel assembly reconstitution evaluation methodology currently under NRC review, Reference 10. The evaluation assessed the safety significance of fuel assembly reconstitution and assured that the reconstituted Cycle 5 core met tl.e design criteria for the existing fuel designs.

Fuel rod reconstitution affects predictions of departure from nucleate boiling (DNT) in hot channels, due to a local power reduction and resultant enthalpy and flow changes.The DNB effects of fuel reconstitution I

were evaluated for Cycle 5, considering the number and location of fuel rods reconstituted. khe DNB design basis in Reference 3 is applicable to the reconstituted core. The design basis in Reference 3 states that there will be at least a 95 percent probability at a 95 percent confidence level that DNB will not occur on the limiting fuel mds during nonnal operation and operational transients and any transient conditions arising from faults of moderate frequency (Condition I and II events). In order to meet this basis, the minimum DNB ratio (DNBR) is determined to be above the Safety Limit DNBR.

It is conservative to assume a reconstituted assembly as a regular assembly in DNB analyses because of the DNB margin gained from local power reduction in the reconstituted fuel assembly. The power reduction results in less enthalpy rise and flow increase in the reconstituted assembly. However, the reconstituted assemblies have an effect on the DNB margins of the adjacent fuel assemblies in the core.

4.2 Methodology Discussion

'lhe DNB effects of fuel reconstitution were evaluated in Reference 10 using the THINC-IV code i

(References 8 and 9). Both the subchannel effects (within the reconstituted assembly) and the corewide effects (adjacent assemblies) were evaluated using THINC-IV.

{

Based on the study described in Reference 10 for the subchannel effects of filler rods in reconstituted fuel assemblies, DNB margin is gained from the local power reduction in the reconstituted fuel assembly. Cold wall effects on DNB due to an unheated surface fmm solid filler rods and coolant mixing were also l

Rev 03C993 9:15am 9

-r

l investigated in Reference 10. The Vogtle fuel assembly designs provide adequate coolant mixing with the use of mixing vane grids. The conclusions in Reference 10 regarding the cold wall effect is applicable to Vogtle Unit 1 Cycle 5 based on the fuel assembly designs and the DNB correlations used.

l Fuel reconstitu5cn may result in a flow redistribution among fuel assemblies due to a change in radial power gradient. The corewide effects on enthalpy rise and DNB were evaluated.

The Vogtle reconstituted Cycle 5 loading pattern is less limiting than the evaluation in Reference 10. For Vogtle Unit 1 Cycle 5, the corewide effects are negligible.

Fuel reconstitution may also affect the core average heat flux due to a reduced heat transfer area.

However, one solid filler rod replacing the damaged fuel rod in the Vogtle Unit 1 Cycle 5 loading pattern had a negligible effect on DNB due to the slight increase in core average heat flux. The specific evaluations which were performed for Vogtle Unit 1 Cycle 5, considering the exact configuration and associated core power distribution of the reconstituted assembly, confirmed that the reconstituted assembly 4

was bounded by a regular assembly in DNB analyses and the DNB design basis was met f

3 t

4 k

l i

i i

l

=J Rev 030993 9:15am 10 I

i

i I

5.0 NON-LOCA METIIODOLOGY 4

5.1 Non-LOCA Evaluation Methodology Reload safety analyses 'were performed for Vogtle Unit 1 Cycle 5 in accordance with the reference i

analysis approach discussed in Reference 3. This process confinns whether or not a core configuration is bounded by the existing safety analyses, and verifies that applicable safety criteria are satisfied for the reload design. For those cases in which the existing safety analyses prove to be no longer bounding, the L

process also identifies the potentially impacted licensing basis events.

i The methodology systematically identifies parameter changes on a cycle-by-cycle basis which may invalidate existing safety analyses and identifies those events which need to be evaluated. If a parameter is only slightly,out of bounds, or the transient is relatively insensitive to that parameter, a simple qualitative evaluation may be made which conservatively evaluates the magnitude of the effect and explains why the actual analysis of the event does not have to be repeated. Alternatively, should the deviation be large and/or expected to have a more significant or not easily quantifiable effect on the analysis, a reanalysis of the accident is performed. If the accident is reanalyzed, the analysis methods follow standard procedures and will typically employ analytical methods which have been used and approved in previous submittals to the NRC. 'Ihese methods are those which have been presented in the FSAR, subsequent sutrnittals to the NRC for a specific plant, reference SARs, or repons submitted for NRC approval.

I The reload evaluation process has been expanded to facilitate the evaluation of new or modified fuel designs. This is accomplished as specified in the Standard Review Plan (SRP) Section 4.2 (Reference 1),

Subsection ", "For operatmg license (OL) applications, the review should confirm that the design bases set fonh in the Final Safety Analysis Report (FSAR) meet the acceptance criteria given in Subsection II t

A" of SRP 4.2, "and that the final fuel system design meets the design bases.". 'Ibe SRP Section 4.2 complements the sticad safety reanalysis methodology by outlining a process and estabhshing acceptance criteria for enabling the evaluation of new or modified fuel designs which may be incorporated in the reload cores. Provided that the new or modified fuel design meets the criteria specified in the SRP Section 4.2, NRC review and approval is not necessary. *Ihe SRP Section 4.2 allows for 10CFR50.59 conclusions to be reached by demonstrating that the criteria defined in the SRP Section 4.2 are used for the evaluation Rev 03r9/93 9:15am II

L I

~

of the fuel mechanical change (s) such as reconstitution and are met. De only change that will be needed to the Technical Specifications is in the Design Features Section 5.3.1, currently under NRC review.

r The reload safety analysis methodology as described by Reference 3, systematically identifies reload core changes on a cycle-by-cycle basis as well as changes in fuel design which may invalidate existing safety analyses. He process also identifies those licensing basis events that need to be re-evaluated should this be necessary.

5.2 Methodology Discussion A review was made of all of the criteria (design parameters) found in the SRP (Reference I). The SRP design parameters were reviewed for adequacy and completeness in view of the proposed Vogtle Unit I Cycle 5 fuel assembly reconstitution. The SRP design parameters which may be impacted due to fuel reconstitution and which may have an adverse impact on the non-LOCA licensing basis analyses were evaluated.

These design parameters are of primary importance in the non-LOCA licensing basis analyses due to the assumptions and licensed methods which are currently used. De potential for impact results from the removal of fuel rods which will increase the core average kw/ft (for a given power level). This in tum will f

increase nominal fuel temperatures and fuel rod heat flux.

Increases in the nominal fuel and clad temperatures and fuel rod heat flux may impact the non-LOCA licensing basis analysis results for peak fuel and clad temperatures as well as the margin to the critical heat flux (minimum DNBR). The SRP criteria above include all of these potential effects. It has been concluded that these design parameters are adequate for evaluating the non-LOCA analysis impact of the proposed fuel reconstitution for Vogtle Unit 1 Cycle 5. These design parameters were evaluated for the reconstituted Cycle 5 core as part of the reload process (Reference 3). The results of the reload analysis verified that the conclusions of the non-LOCA accidents in the Vogtle updated FSAR remain valid.

I i

Rev 03/29/93 9:15am I2 i'l

1 i

i 6.0 LOCA METHODOLOGY 6.1 LOCA Evaluation Methodology Changes to the Vogtle ([ nit 1 Cycle 5 fuel were evaluated to assure that the licensing basis analyses remain valid with the use of a filler rod. The Reload Methodology described in Reference 3 was followed to assure that fuel parameters significant to the Emergency Core Cooling System (ECCS) analyses remain bounded or acceptable with respect to comparable analysis parameters values.

Reconstitution of a Vogtle Unit 1 Cycle 5 fuel assembly represents a change to the fuel which can be addressed in the context of the reload valuation. The Standard Review Plan (Reference 1)(Section 4.2, Subsection Ill) specifies that *the review should confirm that the design bases set forth in the Final Safety -

Analysis Report (FSAR) meet the acceptance criteria given... and that the final fuel system design meets the design bases." By evaluating potential effects of reconstitution on the licensiag basis analysis, anticipated changes in analysis results can be quantified and tracked during residence time for which the reconstituted fuel assembly is in the core. He result of this evaluation is the confirmation of continued compliance with acceptance criteria of 10CFR50.46.

The steady state and transient effects of reconstituted assemblies on large and small break loss-of-coolant accident (LOCA) analyses are described in WCAP-13060-P (Reference 10). An evaluation of the potential effects of reconstitution on the ECCS analyses was performed to demonstrate continued compliance to the acceptance criterion of 10CFR50.46. He methodology by which reconstitution of a Vogtle Unit 1 Cycle 5 fuel assembly was evaluated is described below.

6.2 Methodology Discussion The following LOCA evaluation methodology is def' ed for application to Vogtle Unit 1 Cycle 5:

m 1.

For reconstitution with stainless steel filler rods, a limiting case of the stainless steel filler rods will be conservatively assumed.

2, The Vogtle Unit 1 Cycle 5 steady state evaluation resulted in a negligibic increase in Peak Clad Temperature (PCI) for the Large Break LOCA (LBLOCA). Therefore, a conservative penalty of 1*F will be assess 3 to cover the steady state effects for the LBIDCA.

Rev 0309S3 9:15am 13 l

1

e 3.

Based on the number of damaged fuel rods replaced, the potential increase in linear heat rate required to retain total core power constant at its rated value was calculated. This change was evaluated for Vogtle Unit 1 Cycle 5 which resulted in a conservative assessment of a l'F PCT e

penalty for both LBLOCA and the Small Break LOCA (SBLOCA).

De LBLOCA and SBLOCA PCT affect of 2*F and 1*F, respectively, will be added to the sum of the l

evaluations performed to date, and the calculated PCT for the Vogt!c plant as analyzed with respect to i

10 CFR 50.46 reporting requirements. This reconstitution penalty will be tracked throughout the period f

of core residence for the affected assembly. Upon removal of the reconstituted assembly at a future Vogtle reload, the penalty will be removed from the Vogtle assessment against PCT margin. It should r

be noted that the PCT effects calculated for reconstitution are considered to be due to plant changes and not due to ECCS evaluation model changes. The absolute value of these changes will not be considered in the cumulation of changes to the Evaluation Model for purposes of determining if the cumulation of changes is significant as defined by 10CFR'i).46.

With respect to the Standard Review Plan (Reference 1) (Section 4.2, Subsection III), assurance of adequate PCT margin for these small penalties was confirmed. This approach answers directly the criterion regarding changes to the LOCA fuel clad peak temperature. The methodology, as described and developed, also a!! owed the analyst to make an evaluation on each of the other LOCA related crie.ria j

which showed no change to fuel rod clad rupture, extent of blochage to assure fuel coolability and l

t structural response to LOCA loads. Presuming ongoing tracking and available margin, this will be an adequate treatment for use in the Vogtle Unit 1 Cycle 5 reload. On the basis of these findings, the Vogtle Unit 1 Cycle 5 reconstitution can be licensed with respect to the LOCA analysis (SBLOCA and LBOOCA) under the auspices of 10CFR50.59 per the evaluation process discussed above.

l i

i l

Rev 03/2993 9:15ars 14 I

i i

b

'U

7.0 REFERENCES

1.

U. S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation, " Standard Review Plan 4.2," SRP 4.2, Revision 2, July 1981.

2. -

Davidson, S. L (Ed.), " Verification Testing and Analyses of the 17x17 Optimized Fuel Assembly,"

WCAP-9401-P-A, August 1981.

3.

Davidson, S. L (Eds.), et. al., " Westinghouse Reload Safety Evaluation Methodology,"

WCAP-9272-P-A, July 1985.

4.

Davidson, S. L (Ed.), et. al., " Reference Core Report VANTAGE 5 Fuel Assembly," WCAP-10444-P-A, September 1985.

5.

Davidson, S. L (Ed.), et. al., " Extended Burnup Evaluation of Westinghouse Fuel," WCAP-10125-P-A (Proprietary) and WCAP-10126-A (non-Proprietary), December,1985.

6.

Davidson, S. L and lorii, J. A., " Reference Core Report 17x17 Optimized Fuel Assembly,"

WCAP-9500-A, May 1982.

t 7.

Weiner, R. A., et. al., " Improved Fuel Performance Models for Westinghouse Fu:1 Rod Design and Safety Evaluations," WCAP-10851-P-A (Proprietary) and WCAP-11873-A (non-Proprietary),

August 1988.

I 8.

Chelemer, H. and Hochreiter, L E., " Application of the TIIINC-IV Program to PWR Design,"

j WCAP-8054-P-A, February 1989.

9.

Friedland, A. J. and Rey, S., " Improved THINC-IV Modeling for PWR Core Design,"

WCAP-12330-P, August 1989.

i 10.

Slagle, W. H. " Westinghouse Fuel Assembly Reconstitution Evaluation Methodology,"

WCAP-13060-P, March 1993.

Re,03a9/93 9:15ar.

15

,