Errata to Safety Evaluation Supporting Amend 90 to License NPF-11.Correction Changes Typo on Page Nine That Could Cause Some Confusion
ML20035B120
Person / Time
Site: LaSalle 
Issue date: 02/24/1993
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20035B121 List:
References
NUDOCS 9303310165
Download: ML20035B120 (1)


Text

i S

(~.

l

- l l

the standard LaSalle core geometry, which is defined as an infinite array of fuel assemblies located in a 6-inch lattice spacing in unborated water at 20 *C, without any control absorber or voids present. Thus, any fuel assembly which has a k, of 1.332 or less at 20 *C in the standard core geometry, and an average enrichment of 4.6 w/o or less in the enriched zone, will result in a k,,, of less than 0.8973 (0.9241 including uncertainties) when stored in the spent fuel rack, and will meet the fuel storage reactivity criterion specified in the SRP. Thg5 staff considers storage of fuel with average enrichments of up to 4.25 w/o 0 (4.6 w/o in the enriched zone) to be acceptable, provided l

that the storage configuration of fuel assemblies does not result in a local

k. of 1.332 or greater, when calculated as described above. The licensee will be expected to verify that the k,, of the limiting lattice, at all potential l

fuel burnups, remains less than this limit.

l The licensee considered the reactivity effects of abnormal and accident conditions due to temperature and water density effects, eccentric fuel assembly positioning, fuel rack lateral movement, or the drop of a fuel assembly on top of the storage rack. None of the credible conditions resulted in exceeding the SRP maximum reactivity criterion of k,,, 5; 0.95.

The proposed storage racks will also contain four large, square cells with an inside dimension of 11.5 inches. These cells are designed to store control rod guide tubes or defective fuel containers. The licensee's calculations determined that the storage of defective fuel containers loaded with fresh fuel in these cells would result in a maximum k,, of approximately 0.74.

This result is also well within the SRP maximum reactivity requirement.

2.5 Structural Desian 2.5.1 Hioh Density Racks L

The proposed high density spent fuel storage racks are seismic Category I equipment, and are required to remain functional during and after a safe shutdown earthquake (SSE). The licensee used a computer program, DYNARACK, for dynamic analysis to demonstrate the structural adequacy of the spent fuel rack design under earthquake loading conditions. The proposed spent fuel racks are free-standing and self-supporting equipment, and are not attached to the floor of the storage pool. A nonlinear dynamic model consisting of inertial mass elements, spring, gap, and friction elements as defined in the program was used to simulate three dimensional dynamic behavior of the rack including frictional and hydrodynamic effects. The program calculated nodal forces and displacements at the nodes, and then obtained the detailed stress field in the rack elements from the calculated nodal forces.

The seismic analysis was performed utilizing the time-history method. The seismic time histories were calculated from the plant floor response spectra (FRS) as described in the LaSalle County Station UFSAR.

For stress and displacement analysis, three rack geometries were considered:

(1) 15 feet x 17 feet, (2) 15 feet x 18 feet, and (3) 9 feet x 18 feet.

Each rack was considered fully loaded, partially loaded, and almost empty with three different coefficients of friction between the rack and the pool floor 9303310165 930322 PDR ADOCK 05000373 P