ML20035A139

From kanterella
Jump to navigation Jump to search
Application for Amend to License SNM-1097,requesting Mods of Ventilation Requirements in Table 3.1, Specific Facilities & Capabilities... to Allow Increased Flexibility in Maintaining Work Area Air Concentrations ALARA
ML20035A139
Person / Time
Site: 07001113
Issue date: 03/18/1993
From: Winslow T
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Jim Hickey
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9303240141
Download: ML20035A139 (7)


Text

x.

/>

,., m 1

/6 L/// }

}

' GE Nuclear Energy

r" s my;s c; n m

~r c

x;

.. m sw March 18, 1993 Director Office of Nuclear Materials Safety & Safeguards U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. John W.

N.

Hickey, Chief Fuel Cycle Safety Branch l

OWFN, Room 6H6, Mail 6H3

Dear Sir:

Subject:

License Amendment Request (Revision 139)

Reference:

SNM Material License SNM-1097, Docket # 70-1113 l

t With reference to activities authorized by NRC License SNM-1097 at the General Electric Nuclear Fuel and Components Manufacturing (NF&CM) facility, GE requests approval for the enclosed page changes hereby submitted for Part I of our current application.

This amendment requests modification of the ventilation requirements in Table 3.1,

" Specific Facilities & Capabilities of Ventilation Systems" to allow for increased flexibility in maintaining work area air concentrations As Low As Reasonably Achievable (ALARA).

The modification consists of deleting the i

requirement for eight room air changes per hour.

Our experience indicates that the number of room air changes is a t

poor basis for ventilation criteria where control of airborne materials is required.

Because of increased air turbulence, there appears to be-minimal relationship between air changes and desired airborne levels. Airborne concentrations can be better controlled i

to desired levels by proper use of other engineered methods.

i l

In addition, a specified number of room air changes may negatively l

impact other airborne reduction methods currently being evaluated at our facility such as work area isolation and laminar flow i

designs.

1 contains an explanation of the requested changes by page and section. contains the license pages by date I

of revision. contains the revised page changes to conditions of Part I of our current license application.

9303240141 f50318 l\\

PDR ADOCK 07001113 C

PDR

,,1

m.

l j

i i

j~

j

i. O i

Director - ONMSS l

March 18, 1993 l

l Page 2 l

i

.t 8

1 a-Changes to the amendment pages are indicated with an asterisk (*)

[

in the right-hand column of each page.

I In accordance with 10 CFR 70.21(a) (2), six copies of this i

l application are being provided.

1 If you require additional information or would like to discuss t

this matter further, please contact me at (919) 675-5461.

'l I

Sincerely, i

l GE NUCLEAR ENERGY l

l l.

  1. A&M l

i

{.

T. Preston Winslow, Manager

-l i

l Licensing & Nuclear Materials Management l

I i

/sbm cc:

Region II, Administrator l

l l-TPW-93-030 k

i 1

l l

t i-i s

l-t l

l i

I l

i i

tlO i

l L

~...

- -. ~..

4 Director - ONMSS March 18, 1993 Page 1.of 1 i

ATTACHMENT 1 l

1 Page Section Description l

8 Changed " Revision by Page" section to reflect changes-made in this submittal.

I-3.7 3.2.2 Deleted requirement for a minimum of 8 Table 3.1 room' air changes per hour.

1 1.

l l

l

....a..

.. _ i.

i

-l i

4 Director - ONMSS March 18, 1993 Page 1 of 1~

ATTACHMENT 2 PAGE REVISIONS BY DATE O

l L

l A

i-;

i REVISIONS BY PAGE Application Application Application Page Date Page Date Page Date j

TABLE OF CONTENTS I-1.21 5/16/88 I-3.3 10/23/87 I-1.22 I-3.4 i

l 1

10/23/87 I-1.23 I-3.5 2

I-1.24 I-3.6 3

I-3.7 03/18/93 4

I-3.8 10/23/87 5

CHAPTER 2 I-3.9 i

6 I-3.10 7

I-2.1 2/06/89 I-3.11 i

8 03/18/93 I-2.2 I-3.12 9

10/13/92 I-2.3 I-3.13 i

10 12/17/92 1-2.4 I-3.14 11 2/06/89 I-2.5 I-3.15 12 10/13/92 I-2.6 I-3.16 I-2.7 I-3.17 05/06/92 I-2.8 I-3.18 I-2.9 I-3.19 PART I I-2.10 I-3.20 I-2.11 I-3.21 I-2.12 I-3.22 CHAPTER 1 I-2.13 I-3.23 a

I-2.14 I-3.24 j

)

I-1.1 5/16/88 I-2.15 I-3.25 I-1.2 I-2.16 I-3.26 I-1.3 I-2.17 I-3.27 I-1.4 10/22/91 I-2.18 I-3.28 I-1.5 5/16/88 I-2.19 I-1.6 I-2.20 I-1.7 12/03/90 1-2.21 I-1.8 5/16/88 I-2.22 CHAPTER 4 I-1.9 I-2.23 I-2.24 I-4.1 10/23/87 I-1.10 I-1.11 I-2.25 I-4.2 I-1.12 I-2.26 I-4.3 I-1.13 I-4.4 I-1.14 I-4.5 I-1.15 I-4.6 i

I-1.16 CHAPTER 3 I-4.7 I-1.17 I-4.8 I-3.1 10/23/87 I-4.9 I-1.18 I-1.19 I-3.2 I-4.10 I-1.20 4/16/92 I-4.11 I-1. 2 0 (a) 9/24/92 1

I)

LICENSE SNM-1097 DATE 03/18/93 Page DOCKET 70-1113 REVISION-39 i

=

1 Director - ONMSS' l

. =..9 March.18, 1993-1 Page 1 of 1 l

ATTACHMENT 3 REVISED PAGE CHANGE TO CONDITIONS OF PART I OF OUR CURRENT LICENSE APPLICATION O

i e

TABLE 3.1 SPECIFIC FACILITIES & CAPABILITIES T VD1TIIATICN SYSTEMS Alarms, Interlocks &

Facility Safety Features Purpose Hoods Air flow during operation Prevents spread of

~> 80 lineal feet per minute radioactive materials frm work area to inmediate rom area Fire extinguishers in work Provides fire prevention area i

Effluent air filtered with Prevents release of l

HEPA filters radioactive materials to environs High Velocity Air flow designated to Prevents spread of radio-Local Exhaust maintain an average of 200 active materials from work j

lineal feet per minute area to innediate room area Sintering Automatic hydrogen shutoff Protects against hydrogen Furnaces and switch over to nitrogen explosion and resultant witn alarm signal spread of contamination as O

well as physical injury to rom occupants UFs Tenperature controller and Controls temperature to not vaporization alarm exceed 300 F, which is 40 F Chambers below the temperature at which unsafe cylinder pressure might be generated 1

-l Ventilation enclosure Provides containment in event of cylinder rupture or abnormal leakage Recirculating Air filtered in potentially Pemoves essentially all Air Systems contaminated zones with HEPA contaminants from room and

& Exhaust filters or water scrubbers exhaust to environs Air Syste:rs

. LICENSE SNM-1097 DATE 3/18/93 Page DOCKET 70-1113 REVISION 39 I-3.7 3

_ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _