Forwards Order Imposing Civil Monetary Penalty in Amount of $8,000 for Violation Re Failure to Wear Alarming Ratemeters During Radiography Operations
ML20035A057
Person / Time
Site: 15000030
Issue date: 03/22/1993
From: Thompson H
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To: Clay Johnson
WESTERN TECHNOLOGIES, INC.
Shared Package
ML20035A058 List:
References
EA-92-216, NUDOCS 9303240013
Download: ML20035A057 (2)


Text

-

E i

pmM49

- f

.,j UNITED STATES

(

j NUCLEAR REGULATORY COMMISSION

+(

WASHINGTON, D.C. 20566-0001 l

~

MAR 2 21993

\\

Docket 150-00030 General License (10 CFR 150.20) i EA 92-216 j

Western Technologies, Inc.

i ATTN: Mr. Craig Johnson i

Vice President Post Office Box 21387 l

Phoenix, Arizona 85036 i

SUBJECT:

ORDER IMPOSING CIVIL MONETARY PENALTY - $8,000 5

This refers to your letter dated January 26, 1993, in response to the Notice of Violation and Proposed Imposition of Civil Penalty ~

(Notice) sent to you by our letter dated December 28, 1992.

Our letter and Notice described a violation of 10 CFR 34.33(a),

i.e.,

a failure to wear alarming ratemeters during radiography operations.

1 To emphasize the seriousness of willful violations, the importance of strict compliance with safety requirements, and the t

importance of developing mechanisms to ensure that company l

personnel are complying witii such requirements, a civil penalty of $8,000 was proposed.

In your response, you admitted this violation but requested full j

mitigation of the proposed penalty based on a number of factors.

A summary of the reasons for your request for mitigation'is

-j contained in the enclosed Order.

After consideration of your request'for mitigation, we have concluded for the reasons given in the appendix to the enclosed Order Imposing civil Monetary Penalty that the full amount of the-penalty should-be imposed by order.

Accordingly, we hereby serve the enclosed Order on Western Technologies, Inc., imposing a civil monetary penalty in the amount of $8,000.

The NRC will-review the. effectiveness of your corrective actions during future inspections.

i e

l, i

9303240013 930322

{

PDR STPRC ESCAZ PDR' i

p';

i s

/

J

h Western Technologies, Inc. In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice",

a copy of this letter and the enclosure will be placed in the NRC's Public Document Room.

Sincerely, L

11/Af Hug L. Thomps/n, D

ty Executive i ector for Nuclear Materials afety, Safeguards, and Operations Support

Enclosure:

As Stated I