Forwards Safety Insp Repts 50-454/93-03 & 50-455/93-03 on 930222-26.No Violations Noted
ML20034H167
Person / Time
Site: Byron  Constellation icon.png
Issue date: 03/09/1993
From: Snell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Delgeorge L
COMMONWEALTH EDISON CO.
Shared Package
ML20034H168 List:
References
NUDOCS 9303160124
Download: ML20034H167 (2)


See also: IR 05000454/1993003

Text

pop

-

..

.

Docket No. 50-454

MAR

9 1993

Docket No. 50-455

Commonwealth Edison Company

ATTN: Mr. L. O. DelGeorge, Vice President

Nuclear Oversight and

Regulatory Services

Executive Towers West III

1400 Opus Place, Suite 300

Downers Grove, IL 60515

Dear Mr. De1 George:

SUBJECT:

ROUTINE RADIATION PROTECTION INSPECTION AT BYRON NUCLEAR POWER

STATION

This refers to the routine safety inspection conducted by Mr. T. J. Kozak of

this office on February 22-26, 1993. The inspection included a review of

authorized activities for your Byron Nuclear Power Station. At the conclusion

of the inspection, the findings were discussed with those members of your

staff identified in the enclosed report.

Areas examined during the inspection are identified in the report. Within

these areas, the inspection consisted of a selective examination of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

No violations of NRC requirements were identified during the course of this

inspection.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosed inspection report will be placed in the NRC

Public Document Room.

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

Original Signed O William Snell

William Snell, Chief

Radiological Controls Section 2

Enclosure:

Inspection Reports

No. 50-454/93003(DRSS);

No. 50-455/93003(DRSS)

See Attached Distribution

RIII

RIM

RIII

'

W_ V

AS

Kozaktdg

Farber

Inell

,

03/s'/93

) g3

y/g/

9303160124 930309

/Cb

PDR

ADOCK 05000454 .

-

G

PDR

/)9

IQ

_

.

4

MA3

0

^

Commonwealth Edison Company

2

Distribution

cc w/ enclosure:

K. Graesser, Site Vice President

G. Schwartz, Station Manager

D. Brindle, Regulatory Assurance

Supervisor

D. Farrar, Nuclear Regulatory

Services Manager

DCD/DCB (RIDS)

OC/LFDCB

Resident Inspectors, Byron,

Braidwood, Zion

Richard Hubbard

J. W. McCaffrey, Chief, Public

utilities Division

Licensing Project Manager, NRR

Robert Newmann, Office of Public

Counsel

Robert M. Thompson, Administrator

Wisconsin Division of Emergency

Government

State Liaison Officer

Chairman, Illinois Commerce

Commission

- .