1011 03 153 Docket Nos. 50-54 70-687 Mr. James J. McGovern Plant Manager Cintichem, Inc.

P. O. Box 816 Tuxedo, New York 10987

Dear Mr. McGovern:

Subject:

Results of NRC TLD Direct Radiation Monitoring Around the Cintichem Facility The results of the subject monitoring for the fourth quarter of 1992 are provided in the enclosure. Questions regarding this program may be directed either to me or to Dr. Richard K.

Struckmeyer of my staff.

Sincerely, Original Signed ty bene.. Y ukk ep arie T. Miller, Chief Effluents Radiation Protection Section Division of Radiation Safety and Safeguards i

Enclosure:

As Stated 4

OFFICIAL RECORD COPY A:CINT5054.RV1 March 2,1993

]f ?f-l 9303120043 930303

? 8"'

PDR ADOCK 05000054 E.

i

{1 P

PDR scm v

i

f I/M 03 163 l

1 Cintichem, Inc.

2 cc w/ encl:

J. Adler, Manager, Health, Safety, and Environmental Affairs F. Morse, Project Manager, Decommissioning Dr. W. Vernetson, TRTR Dr. P. Merges, Director, Bureau of Radiation, NYS-DEC Mr. G. L. Kasyk, Principal Radiophysicist, Radiological Health Unit, NYS-DOL

^

Ms. A. Dorozynski, Town of Tuxedo Supervisor Berle, Kass and Case EPA Region II K. Abraham, PAO (2)

Public Document Room (PDR)

Nuclear Safety Information Center (NSIC)

State of New York i

t j

-1 i

1 l

1 I

i OFFICIAL RECORD COPY A:CINT5054.RV1 March 2,1993 i"* ~

i 9

l q

l 9

r-i flAR 0 31993 Cintichem, Inc.

2 l

cc w/ encl:

J. Adler, Manager, Health, Safety, and Environmental Affairs F. Morse, Project Manager, Decommissioning Dr. W. Vernetson, TRTR j

Dr. P. Merges, Director, Bureau of Radiation, NYS-DEC Mr. G. L. Kasyk, Principal Radiophysicist, Radiological Health Unit, NYS-DOL Ms. A. Dorozynski, Town of Tuxedo Supervisor Berle, Kass and Case i

EPA Region II K. Abraham, PAO (2)

Public Document Room (PDR)

Nuclear Safety Information Center (NSIC)

State of New York t

i i

OFFICIAL RECORD COPY A:CINT5054.RV1 March 2,1993 f'%O

D I"

vJ

Wa 0 3 LS Cintichem, Inc.

3 bec w/ encl:

Region I Docket Room (with concurrences)

N. Orlando, NMSS (OWFN 5 E 2)

J. Roth, DRSS T. F. Dragoun, DRSS 4

S. Weiss, NRR (OWFN 11 B 20)

J. Caldwell, NRR/LOLB (OWFN 10D22) t I

i t

i RI:DRS//f bS Struckmeyer Miller 03/03/92 03/3 /92 i

r OFFICIAL RECORD COPY A:CINT5054.RV1 March 2,1993

?~

.O t*

I:P

l 0

CINTICHEM TLD Direct Radiation Environmental Monitoring For the period 920910-930205 149 Days l

Field Time: 99 Days i

Location Gross Net Exposure Rate Hist. Range NRC Azimuth /Dist Exposure (mR)

(mR/Std. Qtr.)

Net Exp Rate i

Sta (Deg)/ (Mi)

+-Rdm; Tot.

+-Rdm; Tot.

+-1 Std Dev l

=

================
=====
==

1 150 3.0 21.3 +- 0.6; 3.2 15.9 +- 0.7; 4.1 16.6 +- 1.6 2

140 2.1 19.6 +- 0.6; 2.9 14.3 +- 0.6; 3.9 14.6.+- 1.7 c

3 133 1.1 Missing Dosimeter No Net Data 16.8 +- 1.4 4

120 0.5 26.2 +- 0.8; 3.9 20.4 +- 0.8; 4.6 20.8 +- 1.7 5

60 1.1 28.6 +- 0.9; 4.3 22.5 +- 0.8; 4.9 24.2 +- 1.1 6

345 1.1 23.2 +- 0.7; 3.5 17.6 +- 0.7; 4.3 18.8 +- 1.5 7

60 0.1 25.3 +- 0.8; 3.5 19.5 +- 0.d; 4.5 20.0 +- 1.6 8

10 0.2 23.5 +- 0.7; 3.5 17.9 +- 0.7; 4.3 19.0 +-'2.2 i

9 230 0.8 22.9 +- 0.7; 3.4 17.3 +- 0.7; 4.3 19.2 +- 4.2 i

10 200 1.4 24.4 +- 0.7; 3.7 18.6 +- 0.7; 4.4 18.6 +- 1.6 l

11 225 2.8 22.1 +- 0.7; 3.3 16.6 +- 0.7; 4.2 17.1 +- 1.9 12 80 2.1 22.9 +- 0.7; 3.4 17.4 +- 0.7; 4.3 15.9 +- 1.6 13 45 5.4 22.0 +- 0.7; 3.3 16.5 +- 0.7; 4.2 17.0.+- 1.6 14 10 6.2 23.0 +- 0.7; 3.5 17.4 +- 0.7; 4.3 17.8 +- 1.6 15 358 3.3 22.4 +- 0.7; 3.4 16.9 +- 0.7; 4.2 17.3 +- 2.0 16 315 5.0 23.8 +- 0.7; 3.6 18.2 +- 0.7; 4.3 18.2 +- 1.7 17 265 4.0 21.0 +- 0.6; 3.2 15.6 +- 0.7; 4.1 15.8 +- 1.4 18 235 6.7 22.9 +- 0.7; 3.4 17.3 +- 0.7; 4.3 17.7 +- 1.3 j

19 235 6.7 21.8 +- 0.7; 3.3 16.3 +- 0.7; 4.1 17.7 +- 1.9 l

20 235 6.7 22.2 +- 0.7; 3.3 16.7 +- 0.7; 4.2 17.8 +- 1.3 j

Transit Dose =

3.9 +- 0.4; 3.2 l

1 i

i i

i CINTICHEM

- 4 For the period 920910-930205 i

TLD Direct Radiation Environmental Monitoring Azimuth Ave. Exposure Rate Number (degrees)

(mR/Std.Qtr.) +- Std.Dev.

In Group l

l 348.76 -

11.25 N 17.4 +-

0.5 3

f 11.26 -

33.75 NNE No Data +- No Data O

I 33.76 -

56.25 NE 16.5 +-

0.0 1

56.26 -

78.75 ENE 21.0 +-

2.1 2

78.76 - 101.25 E 17.4 +-

0.0 1

l f

101.26 - 123.75 ESE 20.4 +-

0.0 1

123.76 - 146.25 SE 14.3 +-

0.0 1

i 146.26 - 168.75 SSE 15.9 +-

0.0 1

l 168.76 - 191.25 S No Data +- No Data 0

191.26 - 213.75 SSW 18.6 +-

0.0 1

213.76 - 236.25 SW 16.9 +-

0.5 2

f 236.26 - 258.75 WSW No Data +- No Data 0

j 258.76 - 281.25 W 15.6 +-

0.0 1

f 281.26 - 303.75 WNW No Data +- No Data O

303.76 - 326.25 NW 18.2 +-

0.0 1

l 326.26 - 348.75 NNW 17.6 +-

0.0 1

i f

Distance From Ave. Exposure Rate Number Reactor (miles)

(mR/Std.Qtr.) +- Std.Dev.

In Group

{

0-2 19.1 +-

1.8 7

t 2-5 16.4 +-

1.2 7

>5 17.0 +-

0.6 2

Upwind control 16.7 +-

0.5 3

e W

f