MaineYankee
~
HEUABLE ELECTRICITY FOR MAINE SINCE 1972
[LD Fnzzie a M]ne 04336 (207) 622-4868 March 1, 1993 MN-93-22 CDF-93-36 UNITED STATES NUCLEAR REGULATORY COMMISSION Attention: Document Control Desk l
Washington, DC 20555-l
References:
(a)
License No. DPR-36 (Docket No. 50-309)
(b) USNRC Letter dated March 19, 1990 - NR_C Bulletin No. 90-01, Loss of Fill-Oil in Transmitters Manufactured by Rosemount (c) MYAPCo Letter to USNRC dated July 3, 1990 (d) MYAPCo Letter to USNRC dated May 9, 1991 (e) USNRC Letter dated December 22, 1992 - NRC Bulletin No. 90-01, Supplement 1: Loss of Fill-0il in Transmitters Manufactured by Rosemount
Subject:
NRC Bulletin No. 90-01, Supplement 1: Loss of Fill-Oil in Transmitters Manufactured by Rosemount Gentiemen:
NRC Bulletin 90-01, Reference (b), informeu licensees that-reported failures of Rosemount Models 1153 and 1154 transmitters were caused by a gradual loss of fill-oil from the transmitters' sealed sensing module. In order to preclude further failures, the NRC requested licensees to promptly identify and take appropriate actions for Model 1153 Series B, Model 1153 Series D, and Model 1154 transmitters manufactured by Rosemount that may be leaking fill-oil. Reference (b) further requested licensees j
to provide a response that confirms the requested actions have been completed and that provides certain other specified information concerning transmitters suspected i
or confirmed of having a loss of fill-oil or from the high failure fraction lots.
By Reference (c), Maine Yankee stated "pending receipt of additional guidance providing a time at pressure basis for acceptance of our present transmitters, Maine Yankee intends to replace all Model 1153 Series B, Model 1153 Series D and Model 1154 transmitters manufactured by Rosemount prior to July 11,1989 installed in safety-class-systems with transmitters manufactured after July 11, 1989 or restored to post July 11, 1989 standards consistent with Rosemount guidance. We plan to complete the repair / replacement of those transmitters by the end of our next_ refueling outage."
By Reference (d), Maine Yankee provided information. relative to a modification in our plan to close out Reference (b) that we considered consistent with the NUMARC Rosemount database.
This modification would have accepted 32 transmitters because of low pressure or exceedence of the Rosemount psi-month criteria.
Subsequent m. ~, '"
080104 9303090522 930301 PDR ADOCK 05000309 O
}
j
Mainehkee 1
UNITED STATES NUCLEAR REGULATORY COMMISSION MN-93-22 Attention: Document Control Desk Page 2 i
discussions with staff personnel during the early fall of 1991 indicated that our conclusions relative to the NUMARC database could not be supported at that time. As i
a result, action was initiated to repair these transmitters during the next outage consistent with Reference (c). This repair / replacement action was completed in April 1992.
i The status of the Reporting Requirements of Reference (e) at Maine Yankee,
}
consistent with the presentation of the Requested Actions, are as follows:
l l
NRC Reauested Action Item No. 1:
Review plant records and identify any Rosemount Model 1153 Series B, Model 1153 l
Series D, and Model 1154 transmitters manufactured before July 11, 1989, that are used or may be used in the future in either safety-related systems or systems installed in accordance with 10 CFR 50.62 (the ATWS rule).
l Maine Yankee Response:
All mohl 1153 Series B,1153 Series D, and Model 1154 Rosemount transmitters I
manufactured prior to July 11, 1989 and installed at Maine Yankee in either safety-class systems or systems installed in accordance with the ATWS rule have been identified and replaced or repaired to post July 11, 1989 standards. Specifically, i
all replacement transmitters have serial numbers greater than 500000 and all repaired transmitters have sensor module numbers greater than 2182605. In addition, all spare i
Rosemount transmitters and sensor modules which may be used in the future meet this criteria.
A listing of all installed Model 1153/1154 transmitters subject to Reference (e) requirements is attached.
i
)
NRC Reauested Action Item No. 2:
Eveluate the enhanced surveillance menitoring program to ensure that the program provides measurement data with an accuracy range consistent with that needed for comparison with manufacturer drift data criteria for determining degradation caused by a loss of fill-oil.
Maine Yankee Response:
As all transmitters or transmitter sensing modules have been replaced, an enhanced monitoring program is not required.
Maine Yankee specifically chose to replace rather than become encumbered by a monitoring program. Thus, Items 1 and 2 of Requested Actions for Operating Reactors of Reference (e) have been completed.
Lt\\93mn\\9322 L
~
MaineYankee UNITED STATES NUCLEAR REGULATORY COMMISSION MN-93-22 Ai.tention: Document Control Desk Page 3 We trust this infonnation is satisfactory.
Please contact us should you have any questions in this matter.
Very truly yours, p
- g Charles D. Frizzle President and Chief Executive Officer l
i CDF/ jag Attachment c:
Mr. Thomas T. Martin l
Mr. E. H. Trottier i
Mr. Charles S. Marschall 1
Mr. Patrick J. Dostie Mr. Alex Marion - NUMARC STATE OF MAINE
\\
Then personally appeared before me, Charles D. Frizzle, who being duly sworn did i
state that he is President and Chief Executive Officer of Maine Yankee Atomic Power Company, that he is duly authorized to execute and file the foregoing response in the name and on behalf of Maine Yankee Atomic Power Company, and that the statements therein are true to the best of his knowledge and be ief.
o
&wh
~
N, t'ary 'Public i
RA J. PADAVANA I ARYPUEJC,WWE UYcOMMISSioN EXP&iE JJr.1E 20,196 I
l l
La\\samn\\s322
- I PAGE 1 0F 2 T
LIST OF ALL ROSEHOUNT TRANSHITTERS - H0DELS 1153 AND 1154 E
XHTR ID' HODEL#
SERIAL # SENSOR SERIAL # INSTRUMENT DESCRIPTION us......................................................................................
1 FT-0311 1154HP4RA 41B321 2665963 HP & AUX. INJ. HDR. TO LOOP 2 FT-0312 1153DD5 403482 2432101 LP INJ. HDR. TO IDOP 1 3 FT-0321 1154HP4RA 418449 2665955 HP & AUX. INJ. HDR. TO LOOP 4 FT-0322 1153DD5 403487 2458775 LP INJ. HDR. TO LOOP 2 5 FT-0331 1154HP4RA 418322 2947578 HP & AUX. INJ. HDR. TO LOOP 6 FT-0332 1153DD5 403481 2472404 LP INJ. HDR. TO LOOP 3 7 FT-3218A 1154HP4RA 420866 2665971 CONTAINHENT SPRAY FLOW 8 FT-3218B 1154HP4RA 420867 2638154 CONTAINHENT SPRAY FIDW 9 LT-0101X 1154DPSRAN0031 501576 NEW XHTR PRESSURIZER VESSEL 10 LT-0101Y 1154DP5RAN0031 501577 NEW XHTR PRESSURIZER VESSEL 11 LT-0303AK 1153DB5PA 409015 2938903 TK-4 LEVEL (RAS) 12 LT-0303BK 1153DB5PA 409017 2942528 TK-4 LEVEL (RAS) 13 LT-0303CK 1153DB5PA 409016 2938918 TK-4 LEVEL (RAS) 14 LT-0304AK 1153DB5PA 409014 2942546 TK-4 LEVEL (RAS)
I 15 LT-0304BK 1153DB5PA 409013 2938905 TK-4 LEVEL (RAS) l 16 LT-0304CK 1153DBSPA 409012 2938897 TK-4 LEVEL (RAS) l 17 LT-1213A 1154DP4RAN0026 417071 2659682 STEAM GEN. E-1-1 LEVEL 18 LT-1213B 1154DP4RAN0026 500564 NEW XHTR STEAM GEN. E-1-1 LEVEL 19 LT-1213C 1154DP4RAN0026 417074 2947577 STEAM GEN. E-1-1 LEVEL 1
20 LT-1213D 1154DP4RAN0026 418297 2947539 STEAM GEN. E-1-1 LEVEL 21 LT-1214 1154DP5RA 420724 2432078 STEAH GEN. E-1-1 LEVEL 22 LT-1223A 1154DP4RAN0026 418295 2641314 STEAM GEN. E-1-2 LEVEL 23 LT-1223B 1154DP4RAN0026 417073 2641318 STEAH GEN. E-1-2 LEVEL 24 LT-1223C 1154DP4RAN0026 417293 2665957 STEAM GEN. E-1-2 LEVEL 25 LT-1223D 1154DP4RAN0026 417072 2659701 STEAH GEN. E-1-2 LEVEL 26 LT-1224 1154DP5RA 420725 2497076 ETEAM GEN. E-1-2 LEVEL 27 LT-1233A 1154DP4RAN0026 418292 2638160 STEAM GEN. E-1-3 LEVEL 28 LT-1233B 1154DP4RAN0026 417075 2665958 STEAM GEN. E-1-3 LEVEL 29 LT-1233C 1154DP4RAN0026 418294 2638116 STEAM GEN. E-1-3 LEVEL 30 LT-1233D 1154DP4RAN0026 418296 2641349 STEAM GEN. E-1-3 LEVEL 31 LT-1234 1154DP5RA 420868 2807225 STEAM GEN. E-1-3 LEVEL 32 PDT-3001 1154DP5RA 501580 NEW XHTR PITS TRAIN A 33 PDT-3002 1154DP5RA 501579 NEW X}frR PITS TRAIN B 34 PT-0102A 1153GD9 403624 2970305 PRESSURIZER VESSEL 35 PT-0102B 1153GD9 403623 2970272 PRESSURIZER VESSEL 36 PT-0102C 1153GD9 403643 2970259 PRESSURIZER VESSEL 37 PT-0102D 1153GD9 403622 2970307 PRESSURIZER VESSEL 38 PT-0102X 1154GP9RAN0010 419693 2896G73 PRESSURIZER VESSEL 39 PT-0102Y 1154GP9RAN0010 419692 2480094 PRESSURIZER VESSEL 40 PT-0103 1153GD9PA 421141 2970288 PRESSURIZER VESSEL el PT-0105 1153GD9PA 408944 2970266 PRESSURIZER LTOP 42 PT-0352K 1153GB7 403329 2708274 RESID. HT. EX. TO CTHT. SPRA.
43 PT-0353K 1153GB7 403328 2456648 RESID. HT. EX. TO CTHT. SPPA.
44 PT-1013A 1153GB8 403128 2951695 STM GEN E-1-1 PRESS 65 PT-1013B 1153GB8PA 406802 2951703 STM GEN E-1-1 PRESS 46 PT-1013C 1153GB8PA 418547 2951686 STM GEN E-1-1 PRESS 47 PT-1013D 1153GB8 403121 2741272 STM GEN E-1-1 PRESS 68 PT-1012 1154GP9RA 420729 2970260 STM GEN E-1-1 WIDE RANGE PRESS 49 PT-1023A 1153GB8 403118 2951698 STM GEN E-1-2 PRESS 50 PT-1023B 1153GB8 403127 2951710 STM GEN E-1-2 PRESS
I PAGE 2 0F 2 T
LIST OF ALL ROSEHOUNT TRANSHITTERS - !!ODELS 1153 AND 1154 E
X1tTR ID
!!ODEL#
SERIAL # SENSOR SERIAL # INSTRUlfENT DESCRIPTION 11#======================================================================================
51 PT-1023C 1153GB8 403119 2951676 STM GEN E-1-2 PRESS 52 PT-1023D 1153GB8PA 411069 2951677 ST11 GEN E-1-2 FRESS f
53 PT-1022 1154GP9RA 420728 2970267 STM GEN E-1-2 WIDE RANGE PRESS l
54 PT-1033A 1153GB8PA 421784 2951702 STM GEN E-1-3 PRESS 55 PT-1033B 1153GB8 403125 2741247 STM GEN E-1-3 PRESS 56 PT-1033C 1153GB8PA 418546 2951708 STl! GEN U-1-3 PRESS 57 PT-1033D 1153GB8 403122 2531207 STM GEN E-1-3 PRESS 58 PT-1032 1154GP9RA 420726 2896039 STil GEN E-1-3 WIDE RANGE PRESS 59 PT-2012 1153AD7 364781 2641415 POST ACCIDENT CTHT PRESS 60 PT-2013 1153AD7 364780 2765015 POST ACCIDENT CTMT PRESS I