Forwards License Amend Request 93-01 to License NPF-86, Changing TS 3/4.7.3 to Redefine Requirements for Operable Primary Component Cooling Water Sys to Enhance Plant Operations & Outage Flexibility
ML20034F521
Person / Time
Site: Seabrook 
Issue date: 02/26/1993
From: Feigenbaum T
NORTH ATLANTIC ENERGY SERVICE CORP. (NAESCO)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20034F522 List:
References
NYN-93031, TAC-M85491, NUDOCS 9303030349
Download: ML20034F521 (2)


Text

i eab ok, NH 03874

)

Telephone (603)474-9521

=

j[h

(

1 Facsimite (603)474-2987 i

Energy Service Corporation Ted C. Feigenbaum l

Senior Vice President and l

l Chief Nuclear Officer NYN-93031 February 26,1993 j

United States Nuclear Regulatory Commission i

Washington, D.C. 20555 l

Attention:

Document Control Desk

Reference:

Facility Operating License No. NPF-86, Docket No. 50-443

Subject:

License Amendment Request 93-01:

" Primary Component Cooling Water System OPERABILITY Requirements" (TAC No. M85491)

Gentlemen:

North Atlantic Energy Service Corporation (North Atlantic) has enclosed License I

Amendment Request 93-01. This License Amendment Request is submitted pursuant to l

10CFR50.90 and is distributed pursuant to 10CFR50.4.

The purpose of License Amendment Request 93-01 is to propose changes to the Seabrook Station Technical Specifications to redefine the requirements for an OPERABLE Primary Component Cooling Water System. The design of the Seabrook Station Primary Component Cooling Water System employs two redundant loops, each with two full capacity primary component cooling water pumps. Operation of any one of the four pumps will satisfy the primary component cooling water requirements during the postulated design basis event.

Seabrook Station's Technical Specification 3/4.7.3 currently requires two OPERABLE i

primary component cooling water loops with each loop having two OPERABLE pumps when in Modes 1, 2, 3, and 4.

This Technical Specification accurately reflects the Seabrook j

Station design, yet,is unnecessarily restrictive due to the redundancy (2 full capacity pumps) in each loop. The proposed changes redefine an OPERABLE primary component cooling water loop as having one OPERABLE pump. Additional changes are proposed to the duration that a primary component cooling water loop can be inoperable and to the surveillance requirements for primary component cooling water pumps. The proposed Technical Specification changes will enhance plant operations and outage flexibility by removing the unnecessarily restrictive redundancy requirements, allowing planned and corrective maintenance to be performed on line without adversely affecting the abilitv of the system to mitigate a postulated design basis event.

A Probabilistic Risk Assessment Evaluation performed by North Atlantic supports the proposed changes.

License Amendment Request 93-01 has been reviewed and approved by the North Atlantic Station Operation Review Committee and the Nuclear Safety Audit Review Committee.

030057 9303030349 930226

^\\

l DR ADOCK 0500 3

member of the Northeast Utilities system

)

i United States Nuclear Regulatory Commission February 26,1993 Attention:

Document Control Desk Page two As discussed in the enclosed License Amendment Request 93-01,Section V, the proposed changes have been determined not to involve a significant hazards consideration pursuant to the standards of 10CFR50.92. A copy of this letter and the enclosed License l

Amendment Request 93-01 have been forwarded to the State of New Hampshire State Liaison Officer pursuant to 10CFR50.91(b). Additionally, North Atlantic has determined that i

f License Amendment Request 93-01 meets the criteria delineated in.10CFR51.22(c)(9) for a categorical exclusion from the requirements for an Environmental Impact Statement (see Section VII, enclosed).

North Atlantic requests NRC review of License Amendment Request 93-01 and issuance of a license amendment by August 26,1993 (see enclosed License Amendment Request 93-01,Section VI).

Should you have any questions regarding this letter, please contact Mr. Terry L.

Harpster, Director of Licensing Services, at (603) 474-9521, extension 2765 f

Very truly yours,

/

6(f g/p V

Ted. Feigenbaum Enclosure TCF:MJM/act cc:

Mr. Thomas T. Martin Regional Administrator U.S. Nuclear Regulatory Commission i

Region I 475 Allendale Road King of Prussia, PA 19406 Mr. Albert W. De Agazio, Sr. Project Manager Project Directorate I-4 Division of Reactor Projects U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Noel Dudley NRC Senior Resident Inspector P.O. Box 1149 Seabrook, Nll 03874 Mr. George L.1verson, Director New Hampshire Office of Emergency Monagement 107 Pleasant Street Concord, NH 03301

.