Docket Number 50-346 License Number NPF-3 Serial Number 1796 April 17. 1990 United States Nuclear Regulatory Commission Document Control Desk Vashington, D. C.
20555 Subj ect: Technical Specification 4.4.5.Sa Report of Steam Generator Tube Plugging i
Gentlemen:
i This letter is submitted in accordance with the requirements of the f
Davis-Besse Nuclear Power Station (DBNPS) Unit Number 1, Operating License Appendix A Technical Specifications. Technical Specification 4.4.5.5a requires Toledo Edison to report to the Nuclear Regulatory Commission (NRC) the number of tubes plugged in each steam generator following each inservice inspection of steam generator tubes.
The tube plugging process was completed on April 6, 1990.
As a result of the i
inspection findings, the following steam generator tubes vere plugged:
l STEAM GENERATOR l-1 STEAM GENERATOR l-2 Roy 38 Tiibe 11 Row 51 Tube 5 Row 69 Tube 61 Rov 68 Tube 10 Row 73 Tube 63 Rov 71 Tube.13 Rov 151 Tube 8 Row 73 Tube 8 Row 73 Tube 9
(
Row 75 Tube 30 Row 77 Tube 29 Row 83 Tube 65 j
In addition to plugging the new tubes above, a number of existing plugs were i
removed from the upper channel head and replaced with new plugs of_a nickel bare alloy [ASME designation SB-166 (alloy 690)) due to the potential for primary water stress corrosion cracking (PVSCC). The plugs vere replaced in the following tubes i
9004270259 900417 p[
PDR ADOCK 05000346 P
'O
+
1HE TOLEDO EOSON COMPANY EDSON PLAZA 300 MADGON AVENUE -
TOLEDO, OHIO 43652 s
r i
Do;ket Number 504346 s,ticense Number NPF-3 Serial Number 1796 Page 2 STEAM CENERATOR 1-1 STEAM GENERATOR 1-2 Row 75 Tube 62 Roy 68 Tube 67 Rov 70 Tube 69 Row.70 Tube 70 Rov 71 Tube 63 Row 71 Tube 71 Row 73 Tube 52 Roy 75 Tube 65 Rov.78 Tube 65 Row 82 Tube 64 Row 82 Tube 66 Roy 82 Tube 69 Row 83 Tube 67 Row 84 Tube 63 Rov 85 Tube 64 Row 85 Tube 65 Row 85 Tube 70 Row 87 Tube 66 Rov 88 Tube 67 l
Additionally, due to vater being observed dripping from Row 54 Tube 127, backup plugs were installed in three tubes in the lover chanael head of Steam i
Generator 1-1 (Row 54 Tube 127, Rov 61' Tube 126, Row 69 Tube 130).
These-tubes had been previously plugged with explosive plugs. The installation of these three backup plugs was completed on April 9, 1990.
In accordance with Technical Specifications 4.4.5.5b and 6.9.1.5b requirements Toledo Edison vill provide information, in the next annual report, on the number and extent of tubes inspected and the location and-percent of vall-thickness penetration for each indication of an imperfection.
Should further information be required, please contact Mr. R. V. Schrauder,
{
Hanager - Nuclear Licensing, at (419) 249-2366.