UNITED STATES NUCLEAR REGULATORY COMMISSION

' jl g

ti

<B WASHINGTON, D C. 20665

  • ty..... /

April-16,- 1990 g

MEMORANDUM FOR: Ashok Thadani, Director Division of Systems Technology FROM:

Robert C. Jones, Chief Reactor Systems Branch i

Division of Systems Technology

SUBJECT:

NOTICE OF FORTHCOMING MEETING WITH WESTINGHOUSE DATE & TIME:

Thursday, April 19, 1990 1:00 - 4:00pm LOCATION:

One White Flint North E

Room 10B-13

' ~ ~ "

11555 Rockville Pike Rockville, MD.

PURPOSE:

Discuss Vantage +/ Advanced Cladding Material (Zirlo) Design PARTICIPANTS:

NRC:

R. Jones. L. Phillips, M. Caruso, S. Wu Westinghouse:

L. Hochrieter, et.' al.

NOTE:

Meeting will be proprietary obert C. J es, Chief Reactor Sys ems Branch Division of Systems Technology cc: See next page Meetings between NRC technical staff and staff contractors are open for l

interested members of the public, petitioners, intervenors', or.other parties i

to attend as observers pursuant to Open Meeting Statement of NRC Staff Policy,a 43 Federal Register 28058, 6/28/78.

Portions of this meeting will be closed to' the public to allow presentation of proprietary infomation.

Contact:

R. C. Jones, SRXB/ DST x20895

/

' 'f gh

/'LD'l l

NRC FILE CENTER COPY v

9004240075 900416 TOPRP EMVW

{DR

1.._

~~

.. J

~

^

. ~'

'}

~

APF-10:'90L15:20 FROM'ECE-WP CTR-BAY-409A PAGE.003 I

r

[k 4

-4 AGENDA FOR WESTINGHOUSE /USNRC MEETING ON 4/19/90

' i o PURPOSE-0F MEETING o VANTAGE +/ ADVANCED CLADDING FUEL DESIGN OBJECTIVES o ADVANCED CLADOING MATERIAL BEHAVIOR - TEST PROGRAM DESCRIPTION

- COMPARISON OF CHEMICAL CONPOSITION WITH ZR 4

- PHASE TRANSITION-I m

^. -..

- THERM 0 PHYSICAL PROPERTIES

- HIGH TEMPERATURE CREEP

- R0D BURST

- HIGH TEMPERATURE OXIDATION KINETICS o LOCA CODE CLADDING MODEL REVISIONS

- SPECIFIC HEAT

- SWELLING

- BURST / BLOCKAGE

- METAL-WATER REACTION

- o SAMPLE LBLOCA CALCULATION WITH ADVANCED CLADDING o PROPOSED EXEMPTIONS TO AFFECTED PORTIONS OF 10CFR50 o LICENSING SUBMITTAL FOR VANTAGE +/ ADVANCED CLADDING FUEL DESIGN o DISCUSSION i

100$H LEH/061090

- L

.l

+

a MEETING NOTICE DISTRIBUTION s

T($si NRC Participants

. @B"R/F-i SRX LPhillips-NRC PDR:

MCaruso JMTaylor(17G-13)

SWu J

TNurley/JSniezek (12G-18)

FMiraglia ' ((12G-18)-

BSheron (NL-007)

DCrutchfield(70-24)

AThadani (7E-4)-

BBoger(14A-2)

Glainas (14H-3)

.1 GHolahan-(13E-4)

JZwolinski (13A-2)

MVirgilio (12E-4)-

' "~

~

WLanning (11E-22)

)

OGC-WF1 (15B-18)-

EJordan(MNBB-3302).

JPartlow (12G-18)).

ACRS.(10)

GPA/PA.(2G-5)

VWilson-(12H-5)

TCox(12E-4)

GuardDesk(1WF) i i

1 J.

o s:

w--

u-