APR 6 1993

. MEMORANDUM FOR:

T. Murley S. Verga J. Richardson J. Snierek G. Holahan J. Zwolinski F. Miraglia C. Rossi A. Thadani J. Partlow J. Roe J. Conran D. Crutchfield F. Congel i

FROM:

Ledyard B. Marsh, Chief Mechanical Engineering Branch Division of Engineering Technology

SUBJECT:

FORTHCOMING MEETING WITH THE BWR OWNERS' GROUP DATE & TIME:

Thursday, May 24,1990 at 9:00 a.m. - 11:00 a.m.

LOCATION:

One White Flint North Room 2 F 17/21 i

11555 Rockville Pike i

Rockville, Maryland 20852 PURPOSE:

Presentation and discussion of the efforts by the BWR Owners' Group to assist licensees in responding to Generic Letter 89-10. " Safety-Related Motor-Operated Valve Testing and Surveillance"

  • PARTICIPANTS:

NRC BWR OWNERS' GROUP J. Richardson D. Attwood, GPC T. Marsh W. Fiock, GE T. Sullivan et al.

T. Scarbrough D. Kiessel E. Brown

0. Rothberg Origlel S!cned By, L B. Ihtt, Chief G. Weidenhamer-A. Gody Ledyard B. Marsh, Chief Mechanical Engineering Branch Division of Engineering Technology
  • Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy,"

43 Federal Reoister 28058,6/28/78.

Distribution:

Centra 1211e; TScarbrough ESu111 van EMEB'RF TScarbrough Valve Distribution List PDR LBMarsh EMS j/p3 l

E ET EMEB:DET T

ugh E5d111 van:

LBMarsh 0I l

/90 y/tl/90 4/(/90 f

i PDR ppg g pgggg

')h h j

9004 0170 90o406

)

IRC FH CENTER COPY

.