OATM

?

O l * * ".C,9 3

[u. g'o giFL i

v n wwn El; r

8'

'Ig

-~

~

UNITEDUATEs f

NUOLEAR REGULATORY COMMISSION h q Q Q (d

bj wAsMiNovow, p. c. rosso MAR 3 01990

$hrm' b) k nn.w an

/# M Y U

13, SGTB:CRH 07003020060R Nuclear Assurance Corporation ATTH: Mr. Charles H. Mayer, Project Manager Engineering and Transportation Systems 6251 Croo ted Creek Road Suite 200 Norcross, GA 30092

Dear Mr. Mayer:

This is in regard to your request for approval of three routes to be used for transport of spent fuel as contained in your letters of November 9, and December 14, 1989. This letter addresses the second of the three routes.

The route from Jenkinsv111e, South Carolina to Lynchburg, Virginia (and even-tually exported from Norfolk, Virginia) as requested in your letters of November 9, and December 14, 1989 is judged to meet the regulatory requirements in accordance with 10 CFR 73.37 for shipment of spent fuel and is approved.

In the event your carrier is required to deviate from the approved route, please call the contact listed on page two of this letter as soon as possible providing details.

Arrangements with law enforcement agencies along the route have been completed by the NRC staff. Data relating to these arrangements and a copy cf the approved route are enclosed. This information is to be incorporated into your shipment plans and provided to your carrier along with instructions regarding its use.

Please note that assuring highway safety is the responsibility of the licensee and carrier, and our approval is not intended to provide relief in this regard.

During seasonal periods when inclement weather with accompanying hazardous road conditions can occur with short notice, the appropriate state police should be contacted with regard to road conditions before a shipment commences.

Please note that the notification requirenents of 10 CFR 73.37(f) and 73.72 for each shipment still apply. When making a notification to a governor or his designee, it should be very specific especially with regard to notification of series shipments. Written notification must designate exactly how many in-dividual shipments are to be included.

In the event the number of shipments in a series is revised, the changed notification should indicate that it is a revision of the original notification and an increase or decrease in the 9004110176 900330 i

PDR ADOCK 07003020

'I C

PDC ypggp, ECD'if.L 07 ATincillAEN1 lillS 00CMMT 15i.

pm dTw,1/t!q.h j gg, / /,, j[

ll c

n sai n=c 1

g g[g wt 0 5 ima s q n, t,. ac6 N Q [kE )S f 1 W @ f & T b ik

' D F03 V

m

Mr. Charles H. Mayer kg 3 p an number of shipments.

In addition, the change notification should specify that the information for any of the shipments in the revised series may not be decon-trolled until tan days after the arrival at the destination of the last shipment e

in that series.

Should you require additional information or have questions concerning this t

matter, please contact Charles Hillman of nty staff at (301) 492-0488.

Sincerely,

[p d

A Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS

Enclosure:

As stated Jenkinsville/Lynchburg (132) 07003020060R Distribution:

w/ enclosure w/o enclosure Docket' File"70-3020' NMSS/SGTB r/f CH111 man 1

l Case File 70-3020 RFonner JCook Region 11 DWeiss RBurnett CHaughney CM6cDonald PDR(Santized) 0FC: 5GTB

5GT S
5GT

. i b

C l

DATE: O /F//90

3 /dQ90 : 3 /D /90 :

0FFICIAL RECORD COPY JENKINSVILLE/LYNCHBURG

t 132 SPENT NUCLEAR FUEL ROUTE VIRGIL C. SUMMER STATION JENKINSVILLE, SOUTH CAROLINA TO BABCOCK AND WILCOX COMPANY LYNCHBURG, VIRGINIA MARCH 3990 1

i l

132

SUMMARY

OF LEA RESPONSE CAPABILITIES AND SAFE HAVENS ROAD TRANSPORTATION ROUTE JENKINSVILLE, SOUTH CAROLINA TO LYNCHBURG, VIRGINIA r

NOTE:

Safe havens are indicated on the route strip charts by a lower case letter of the alphabet in parenthesis.

These safe havens were designated by the NRC route analysis teams with the assistance of law enforcement agencies along the route, as available, for tempo-rary refuge until appropriate assistance arrives.

The basic criteria used to identify a safe haven were availability of a large parking area, nighttime lighting, where possible, and rapid law enforcement l

response to the safe haven.

Should a safe haven be required, refer to the following state summaries for specific identification and location.

i I

- la -

MARCH 1990

132 l

ROAD TRANSPORTATION ROUTE VIRGIL C. SUMMER STATION, JENKINSVILLE, SOUTH CAROLINA TO BABC0CK AND WILCOX COMPANY, LYNCHBURG, VIRGINIA 1

l f

SOUTH CAROLINA 1.

50-215 south / east to I-20*

20 miles 2.

1-20 north / east to I-95 70 miles 3.

I-95 north / east to the North Carolina state line 36 miles Subtotal' 126 miles NORTH CAROLINA 4.

1-95 north to the Virginia state line Subtotal 185 miles VIRGINIA 5.

I-95 north to I-85 49 miles 6.

I-85 west to US-460 7 miles 7.

US-460 west to Mt. Athos Road (VA-726)*

106 miles 8.

Mt. Athos Road north to B&W f acility*

3 miles Subtotal 165 miles 1

Total 476 miles

  • Access to or exit from Interstate or State Preferred Routes MARCH 1990

-l

132 FOOD AND FUEL STOPS o

The businesses and locations listed below were identified by the NRC route analysis teams as possible food and fuel stops.

All possible stops along the route are not listed.

Only a few of the locations were visited by the NRC teams.

In order to be listed, food and fuel stops were required to be close to the route.

SOUTH CARO'.INA 1.

Multiple Food and Fuel Stops.

I-95, Florence County.

2.

Flying "J" Truck Stop.

I-95, exit 181, Marion County, NORTH CAROLINA 1.

The 301 Truck Stop, Fayetteville.

Monitors Citizens Band radio,-

Cumberland County.

2.

Lakewood Truck Stop.

Exit 168, at intersection of I-95 and NC-903, nine miles south of the Virginia and North Carolina state line, Halifax County.

3.

Truck Stops of America.

Exit 176, approximately six miles south of the Virginia and North Carolina state line, Northampton County.

VIRGINIA 1.

Multiple Food and Fuel Stops.

City of Emporia, Greensville County. MARCH 1990

SOUT2 CAROLINA 132 Statewide Essergercy Ntsrber: 911f Flopt#CE COLUMBIA C#eEN WP (803) 661-4705 MP (803) 737-1030 MP (803) 432-6980 S (803) 665-3061 S (803) 779-6100 S (803) 425-1512 MT e a CW 9/19 MT Conus:

MP, S MP, S MP, S LEA:

VIRGIL C.

SUMMER eFlorence E oCottsubia eCamden STAi!ON

]*1 l

  • 2 l

l l

{

  • 3 l0l

{

l Fairfietd l Richtand l

Kershase l

Lee l Der 1ington {Ftorence{'s) Ftorence {

f.lLES IN l

County l County l

County l

County l

Comty l Cotetylrl Cotnty l JtettSDicilom l

12 l

18 l

22 l

20 l

13 l

8 lt]

7 l

l 1

1 1

I I

til i

ToiAL l

l l

l l

l

{nj

{

MILES 0

12 30 52 72 85 lgl 102

{ ton]

93 95 RonD TRANSPORTATION ROUTE - Virgit C. Stammer Stetion, Jeriffsvitte, SC to the KEY Sabcock and vitcon Company Tocitity, Lynchburg, yA

  • 01.

SC-215 south /eest to I-20 (20 miles);

O LEA Response Center

  • 02.

1-20 north /eest to I-95 (70 miles);

MP/SP Mighway Patrot/ State Polict I-95 north /eest to the morth Caroline state tire (36 miles);

  • 03, S

Sheriff CP City Police C'P County Potice CB Radio Monitored (Base) e CS Radio Monitored (Car) a C:*/No.

Channet Menitored it React Group e If unable to contact emergmey number 911, use MT Mobile fetephone (Useebte) the nearest MP number listed above.

E Escort Required Mer-90,

e-

- - + >

m e

- w~--m--

- w-

132 Selft2 CARollma/m0RT2 Canottaa

^

WC Statewide Emergency mister NoEe SC Statewide Emergency misube 911#

(see N ent! 8ef below)

Lt#WERTON FAYETTVILLE

^

MP (919) 739-7501 MP (919) 486-1334 i

l C-yCN 19 WT c CN 19, R Comun:

6 MP RP LEA:

SC l NC i.

]

eLisuberton eFeyetteville (off route) l

==..............................- --


=--.........

I3 l*'

l I

l l

Ditton l

Robeson l

Cisdwrtend

.I Normtt l

KILES IN l

Cotsity l

County l

Coistty l

Cotssty l

JURISDICTION l

24 l

40 l

33 l

9 l

1 I

I I

I TOTAt.

l l

l l

l EILES 102 126 166 199 208 Roe TRM5PORTATION ROUTE - Virgit C. Sesauer Station, Jerdinsv111e, SC to the KEY Babcock and Witcom Cemenny Facility, Lynchburg, VR

03. 1-95 north / cost to the north Corotirio state line (36 miles):

O LEA Response Center

  • 04.

1-95 north to the Virginie stete line (185 mites);

MP/5P Mighuey Petrol / State Police S

Sheriff CP City Police

  1. If tsiebte to ceretect emergency rusdner 911, C'P Commty Potice tsee the neerest MP resuber listed above.

CB Radio Monitored (Base) e C8 Radio Monitored (Car)

O

    1. Roteigh Communications Center, morth Corotine nighuey Petret CN/mo.

Chemet Monitored is 1-800-662-7956.

R React Group MT Mobile Telephone (ttseebte)

Set h inabile telephone is available in North Corotino dint * # P.

E Escort Regitired seer-90.

i

?

g w

?

y

-+y, e

,S-e 4*L e

i*3

-<m 5

g

-w*-

sw

--i>e 4

h

-w~=,-wi--

-e-a-=*wwT-

  1. 0RT2 CAROLim4 132 Stctevide Emergency Nts6er: None Rom 40KE RAPIDS SMITMFIELD WILS08 ROCKY MOUwf MP (919) 934-2186 MP (919) 237-5296 wP (919) &&6-8144 MP (919) 536-2101 MP 1-800-662-7956 MP 1-800-662-7956 (24 Mrs)

Copen:

MT C"~3 CM 9 MT aume CM 9 MT c 3 CM 19 a CM 9 c y CM 19, R MP MP MP LEA:

HP eRoanoke WC l VA eWilson eRocky Mount Rapids l

eSmithfield (off route)]

(off route)

(off route)

I' I

I I

I i

l Johnston l

Witson l

Nesh l

Melifen

  • lNorthamptonj t;tLES IN l

County l

Cotnty l

County l

Courity l County l

JURISDICTIDW j

28 l

17 l

25 l

24 l

9 l

1 I

i l

1 i

TOTAt i

I I

I I

I 236 253 278 302 311 MILES 208 ROAD TRANSPORTAtl04 WOUTE Virgit C. $tsumer Station, Jenkinsvitte, SC to the KEY SeM~6 and witcom Company Facility, Lynchburg, INL

06. 1-95 north to the Virginie state line (185 seites);

o LEA Response Center MP/SP Mighway Patrol / State Potice S

Sheriff CP City Police C'P Cotmty Police CS Radio Monitored (Base) e C8 Radio Monitored (Cer) gy CM/No.

Chamel Monitored R

React Grotp MT Mobile Telephone (Usemble)

E Escort Regtsired Her-90 a

~

vlpGI!!2 132 Stttewide Emergency Ntsuber: None I

BUKEVILLE EMPOR1A PETERS 8URG S (506) 767-5200 CP (804) 634-6502 CP (804) 732-4222 SP 1-800-552-9965 SP (804) &20-3410 SP (804) 733-8219 NT CM 19/9 MT Conse:

C2 S, SP LEA:

CP, SP CP, SP NC l VA eeurkeviite l

eEsporia ePetersburg I

=

_.............=

l*5 I

i

  • 6
  • 7 I

I l

Greensville l

Sussex l

Dinwiddie l

  1. ettowey l

f.lLES IN l

County l

County l

County l

Cotatty l

JURISDICTION l

19 l

20 l

42 l

23 l

1 1

I I

I TOTAL l

l l

l l

MILES 311 330 350 392 415 ROAD TRfWISPORTATION ROUTE - Virgit C. Stsumer Stat cn, Minsvitte, SC to the 8

KEY Babcock and Wilcox Company Facility, Lynchburg, VA

  • 05.

1-95 north to I-85 (49 i=Hes);

O LEA Response Center

  • 06.

1-25 toest to 175-460 (7 miles);

MP/SP Mighway Patrol / State Potice

  • 07.

175-460 west to MT. Athos Reed (VA-726)(106 miln ); and S

She-iff CP City Police C'P Ccunty Police CB Radio Monitored (Sase) e CB Radio Monitored (Car)

CM/No.

Chamet Monitored C

React Gro @

MT Mobile Telephone (Usemble)

E Escort Required Mor-90.

4 u

~ -

-v-

VtRst;tA 132 Statewide Emergerry Number: None LYWCNWlNPG APPOMATTOK FARMVILLE CP (806) 528-6537 S (804) 392-8101 S (806) 352-8241 SP 1-800-552-0962 SP (806) 352-7128 SP 1-800-552-0962 MT g, CW 19/9 MT MT Comen:

CP, SP S, SP S, SP LEA:

SABCDCK AND olynchburg WILC0K CIM-eForsvitte emppemettom PAef F ACILITY

............................................................................=

l l

+8 l

Prince Eduard l

Appomattox l

CaWit l

{T MILES IN l

County l

County l

County l

l 29 l

20 l

12 l

1 I

l JURISDICTION l

l l

l l

TOTAL l

464 476 444 MILES 415 ROAD TRANSPORTATION ROUTE - Virgit C. Summer Stettori, Jenkinsv tte, SC to the a

KEY Babcock and Wilcom Company Facility, Lynchburg, vm

07. US-460 west to Mt. Athos Road (VA-726)(106 miles); and o

LEA Response Center Mt. Athos Road north to the Babcock and Witcom Focility (3 miles).

  • 08.

NP/SP Mighway Patrol / State Police S

Sheriff CP City Potice C'P Cotnty Potice CB Radio Monitored (Bese) e CB Radio Monitored (Car) o j

CN/No.

Channet Monitored R

React Group MT Mobile Telephone (Useable)

E Escort Required Mor-90 -

-.