Responds to 891109 Request for Approval of Routes to Be Used for Transport of Spent Fuel.Route Meets Regulatory Requirements Per 10CFR73.37 & Approved
ML20033F855
Person / Time
Site: 07003020
Issue date: 03/23/1990
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Mayer C
NAC INTERNATIONAL INC. (FORMERLY NUCLEAR ASSURANCE
References
NUDOCS 9004030261
Download: ML20033F855 (8)


Text

.

-Q EDlMQ= !IdCOS5[b v._g m.

18.

y'of '

-, u., v n u

,m i w

UNITED STATES

'? n -

NUCLEAR REGULATORY COMMISSION -.

3 E'M

', 3 -

%,,,,/, E WASHINGTON, D. C. 20555 Mdk A

GIA m, % 4 ;l MAR 2 31990 b)F jf f L.

v*

134~

l 5GTB:CRH' 07003020070R-Nuclear Assurance. Corporation-ATTN: Mr. Charles H. Mayer, Project Manager Engineering and Transportnion Systems 3

6251 Crooked Cree ( Road Suite 200 Norcross, GA 30092

Dear Mr. Mayer:

J

.This is in regard to your request for approval of three routes to be used for transport of spent fuel as contained in your letter of November 9,1989. Tnis letter addresses the third of the three routes.

The-route from Lynchburg,) Virginia to Norfolk, Virginia (and eventually export-ed from Norfolk, Virginia as. requested in your letter of November 9, 1989 is

' judged to meet the regulatory requirements in accordance with 10 CFR 73.37. for

-shipment of: spent fuel and is approved. Also the ports of-Port Elizabeth,.

New Jersey; Baltimore, Maryland; and Portsmouth, Virginia,- through which the.

shipment may transit, are judged to meet the requirements of 10 CFR 73.37.and L.

are approved.

In the event your carrier is required to deviate from the approved route, please call the contact listed on page two of this letter'as soon as possible providing details.

Arrangements with law enforcement agencies along the route have been completed

-by.the NRC staff. Data relating to these arrangements and a copy of the approved L

route are. enclosed. This information is to be incorporated into your shipment L

plans and provided to your carrier along with instructions regarding its use.

t L

Please note that assuring highway safety is the responsibility of the licensee and carrier, and our approval is not intended to provide relief in this regard.

L

.During seasonal periods when inclement weather with accompanying hazardous road

'me.

conditions can occur with short notice, the appropriate state police should be l,j@@f contacted with regard to road conditions before a shipment commences.

. mo J8R Pleasenotethatthenotificationrequirementsof10CFR73.37(f)and73.72 SO

.for each shipment still apply. When making a notification to a governor or y

his designee, it should be very specific especially with regard to notification L No of series shipments. Written notification must designate exactly how many in-LE8@

dividual' shipments are to be included.

In the event the number of shipments Lo in a. series is revised, the changed notification should indicate that it is a l 7:,rr revision of the original notification and an increase or decrease in the SEo OfORREm0VA.0f AT ACHMggTil:S Dof,uhMTis; e

sus }

_h(

ro//oc

.y e

...c

-M, n n n malRUS ny

.. i r-n n r. c n T ; b z PS

.& losu A 1,m eatid,W, M

Wilil i

Mr, Charics H, May3r: MAR 2 31999 number of shipments.

In addition, the change notification should specify that the information for any of the shipments in the revised series may not be' decon.

trolled until ten days after the arrival at'the destination of the last shipment in that series.

~Should you require additional information or have questions concerning this matter, please contact Charles Hillman _of my staff at (301) 492 0488.

Sincerely,_

IS' 0 A u e n [ ) % L a )

Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS

Enclosure:

' As stated Lynchburg/ Norfolk (134)

' 07003020D70R D_istribution:

W/ enclosure w/o enclosure Docket File 70-3020 NMSS/SGTB r/f CHillman Case file 70-3020 RFonner JCook Regions II DWeiss RBurnett CHaughney CMacDonald-PDR (Santized)

SGTB l

OFC: SGTB

SGT

......Q l.,{,

0,3 p 3 NAME:C m9n/19:

CMacUonald :
3 /13/90 : 7 A1/90

_DATE: Ob/ f-/90 OFFICIAL RECORD COPY LYllCHBURG/ NORFOLK L

1 7-; _, :

f =-..

- 13 0 n

s-m

l.

j..

s SPENT NUCLEAR FUEL ROUTE i-L BABC0CK AND WILCOX COMPANY FACILITY, LYNCHBURG, VIRGINIA l.

TO L

NORFOLK INTERNATIONAL TERMINAL, NORFOLK, VIRGINIA

-j l=

MARCH 1990 i

l-1.*

l l:

i l

l

(..

~

1

' l e

i m.

-.i34

SUMMARY

OF LEA RESPONSE CAPABILITIES'AND SAFE HAVENS ROAD TRANSPORTATION ROUTE 1

1 BABC0CK AND WILCOX COMPANY FACILITY, LYNCHBURG, VA TO NORFOLK INTERNATIONAL TERMINAL, NORFOLK, VA NOTEi Safe havens are indicated on the route strip charts by a lower case letter of the alphabet in parenthesis.

These safe havens were designated by the NRC route analysis team: -ith the assistance of

-law enforcement agencies along the route, es available, for tempo-rary refuge until appropriate assistance arrives.

The basic criteria used to identify a safe haven were availability of a large parking area, nighttime lighting, where possible, and rapid law enforcement response to the safe haven.

Should a safe haven be required, refer to the following state summaries for specific identification and location, f

l l

i

- la -

March 1990 1

7 t

L

. ;/

fi34:

y ROAD TRANSPORTATION ROUTE' 4

BABCOCK AND WILCOX COMPANY FACILITY, LYNCHBURG, VA e

TO NORFOLK INTERNATIONAL TERMINAL, NORFOLK, VA-i

. VIRGINIA.

1.

Mt Athos Road (VA-726) south to US-460*

3 miles 2.

US-460 east to~I-85*

106 miles 3..

I-85 east / south to I-95 7 miles-4.

'I-95 south to US-58**'

37 miles 5.

US-58 east to I-64**

66 miles

'6.

1-64 east / north to I-564 19 miles 7.

1-564 west to Terminal Blvd.

1 mile 8.

Terminal Blvd. west to Norfolk International Terminal

-1 mile 240.0 miles E

j.--

l l'

1-L l

1

  • Roads leading to Interstate or state approved route.
    • State approved route - Letter, Commonwealth of Virginia Department of l

Health, January 12, 1984.

L March 1990

i34

-' 9.-

FOOD AND FUEL STOPS q.

The businesses and locations listed below were identified by the NRC route analysis teams as possible food and fuel stops.

All possible stops along the

. route are not listed. Only a few of the locations were visited by the_ NRC teams.

In order to be listed, food and fuel stops were required to be close to the route.

VIRGINIA 1.

Multiple Food and Fuel ' Stops.

City of Emporia, Greensville County.

2.

Multiple Food and Fuel Stops.

City of Franklin, Southampton County.

, March 1990

e;

.g s

m VIRGt!!A

+

134 Statewide Emergency skaber: Wone PETERS 8URG LYNCH 90RG APPOMATTOX FARmr!LLE 1RMEVILLE SP 1-800-552-0962 SP (804) 352-7128 SP 1-800-SP 1-800-552-9965

. SP (804) 733-8219:

CP (804) 732-4222:

CP (804) 528-6537 s (804) 352-8241 552-0962 S (804) 767-5200 NT Conut:

MT c CN 19/9 MT' MT MT SP, CP LEA:

SP, CP SP, S

. SP SP, S BABCOCK AND WILCOX E ePetersburg COMPANT etynchiAsrg eAppomattox eFarmvitte eeurkeville FACILITY j*1

  • 2 l

l l

l

  • 3
  • 4 l

l Campbell l

Appomattox l

Prince Eduard l

.Nottaway l

Difwiddle l

MILES IN l

County l

Cotnty l

Cotmty l

County l

County l

E ISDICT10N l

12 l

20 l

29 l

23 l

42 l

l I

1 I

I i

TOTAL l

l l

l l

l 126 MILES 0

12 32 61 84 ROAD TRAWSPORTATION ROUTE'- Sabcock and Wilcox Company facility, Lynchburg,' VA KEY to the morfolk Internationel Terminot, morfolk, VA

~

  • 01.

MT Athos need (VA-726) south to 175-460 (3 miles);

O LEA Response Center

  • 02.

US-460 eest to I-85 (106 miles);

HP/SP Highway Patrot/ State Police

  • 03.

1-85 eest/ south to 1-95 (7 miles);

S Sheriff

  • 04.

1-95 south to US-58 (37 miles);

CP City Potice C'P County Police CB Radio Monitored (Base) m CB Radio Monitored (Car) a CN/No.

Channet Monitored R

  • eact Group MT Mobile Telephone (Useable)

E

-Escort Required 3

Mar.,o -

I

~

-:v'

  • ~

l

. 134 VIRGI:tA l

(

St:;tewide Emergency Ntaber: None-EMPORIA.

COURTLAND FRANKLIN SUFFOLK CNESAPEAKE

.WORFOLE SP (804) 420-3410 SP (804) 420-3410 SP (804) 420 CP (804) 539-7431 SP (804) 420-M10 -CP (804) 441-2121 CP (804) 634-6502-S (804) 653-2100

-3410 CP (804) 547-6161 CP (804) 562

-8575 CH 9 MT NT c.-y CN 19/9 MT Com:

a CH 19/9 g--3 LEA:

SP, CP SP, S SP, CP CP SP, CP CP NORFOLK

-INTER-oEsporie cCourttand oFrenktin E osuffotk E othesapeake E onorf01k NATIONAL TERMINAL (b) l4 l

  • 5 l

l

  • 6

' l *7

  • 8 l

l Sussex l

Greensville l' Southampton l

Virginie Seech, l Norfolk l MILES IN j

Cotnty l

County

-l County l

Chesapeake and Suffolk l City l JURISDICTION l

20 l

17 l

34 i

Cities l

6 l 1

1 I

i 37 l'

I WAL I

I I

I I

I MILES 126 146 163 197 234 240 ROAD TRANSPORTAfl0N ROUTE - Babcock and Wilcox Company facility, Lynchburg, VA '

KEY to the Norfolk Internationet Terminet, Norfolk, VA 04 I-95 south to US-58 (37 miles);

o LEA Response Center

  • 05.

US-58 east to I-64 (66 miles);

HP/SP Highway Patrol / State Police

  • 06.

I-64 eest/ north to 1-564 (19 mite);

S Sheriff

  • 07.

I-564 west to Terminst 8 tvd. (1 mite); and CP City Police

  • 08.

Terminst Sivd. west to Norfolk International Terminst (1 mile).

C'P County Police CB Radio Monitored (Base) m CB 2adio Monitored (Cer)'

o CH/Co.

Chamet Monitored R

React Group MT Mobile Telephone (Useebte)

E Escort Required. Mar-90

,.