ML20033F484

From kanterella
Jump to navigation Jump to search
Submits Comments on Shielding Section of Application for Amersham Package Model 3100A.Note Should Be Added That Damaged Tungsten Shielding Disc or Rod for Drain Line to Be Replaced
ML20033F484
Person / Time
Site: 07109237
Issue date: 03/08/1990
From: Withee C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Gardes G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9003210202
Download: ML20033F484 (1)


Text

h-7 IIAN I I I

SGTB:CJW Distribution:

71-9237 JE Fue center NRC PDR CJWithee NMSS r/f HEMORANDUM FOR:

George Gardes. SGTB SGTB r/f FROM:

Carl Withee, SGTB

SUBJECT:

REVIEW OF AMERSHAM PACKAGE MODEL N0. 3100A I have reviewed the shielding section of the application for the Amersham Model No. 3100A package, Docket No. 71-9237, and have the follcwing comments.

1 1.

The cporating procedures for loading the cask should have the following additions End modifications:

a.

Add a note that a damaged tungsten shielding disc or shield rod for the drain line, is to be replaced.

b.

Change the radiation survey procedure to a statement that the package external dose rate is to be checked by measurement prior to shipment and give the applicable limits (at cask and package and at the specified distance from the cask or par.kage surface} when the pac

<. age is shipped by regular means and when the surface package is shipped as exclusive use (i.e. full load).

c.

Correct the values for the allowable non-fixed external radioactive contamination (see 10 CFR $71.87 for regular and exclusive use shipments) and use the correct conversion from Bq to Ci.

d.

Correct the values for the allowable internal contamination levels of an empty package.

e.

Add a check'that the stainless steel shielding ring and the tungsten shielding disc are in place.

2.

The applicant should discuss the expected rate and completeness of water draintge from the package when the tungsten shielding disc is in place.

3.

The applicant should provide legible drawings especially #0A23527.

Indicate the position of the purge plug.

+003210202 90030s j

ADOCK07IOQ27 yg g

g f

PDR 0

///7.-

gc,15g19 fy NAME:CJWithee: kds :

DATE* 03/ [ /90

_ OFFICIAL RECORD COPY 71-9237 CJW