ML20033D083
| ML20033D083 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 12/02/1981 |
| From: | Mayer L NORTHERN STATES POWER CO. |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20033D084 | List: |
| References | |
| NUDOCS 8112070203 | |
| Download: ML20033D083 (1) | |
Text
f.
e J
Northern States Power Company 414 Nicollet Mall Minneapohs, Minnawta 55401 Telephone (612) 330-5500 December 2, 1981 gg y
e Director
(
rb Of fice of Nuclear Reactor Regulation
. -1 Attn: Document Control Desk Cl g{gd N
M' U G Nuclear Regulatory Commission (1 u.s.$g
/
5 Washington, DC 20555 Cb 'N.
g /
PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-306 License No. DPR-60 Unit 2 Steam Generator Eddy Current Test Report Attached for your review are four copies of the report. " Inservice Inepection -
Examinat ion Summary, Eddy Current,. Prairie Island Nuclear Generating Plant Unit II, September 6 to September 9, 1981." This is a summary of the eddy current tests conducted after a tube leak developed in Number 22 steam generator on August 19, 1981.
This report is being submitted in accordnace with the Prairie Island ASME Code Section XI Inservice Inspection and Testing Program submitted to the Commission for review on February 1, 1978 (revised through Revision 6 dated July 31, 1981). Submittal of the attached summary is intended to satisfy the inspection report ing requirements contained in IWA-6220 of Section XI of the ASME Code.
Detailed inservice inspection reports are available at our General Office for review by the Region III Office of Inspection and Enforcement.
Please contact us if you have any questions concerning this inspection,
& C.
y L 0 Mayer, PE Manager of Nuclear Support Services LOM/DMM/bd cc: Director, IE-III, NRC (2 copies of attachment)
H Baron, Chief Boiler Inspector, State of Mn (1 copy cf attac! sant)
S Tack, Hartford Ins. (2 copies of attachment)
NRR Project Manager, NRC (w/o attachment)
Resident Inspector, NRC (w/o attachment)
G Charnof f (w/o at tachment) f I 0k A
h8 i L
03 811202 O
K 05000306 PDR
l MY i
i PRAIRIEISLAND NUCLEAR GENERATING PLANT
- 9
.l.
Re'd Eng, Minnesota 1
i-UNITS 1 AND 2 1
1 l
l i
i
'I 1
j M4MME APOU5 e
- 57. PAUL i
LEAR PLANS i
i i
INSERVICE INSPECTION - EXAMINATION
SUMMARY
l PRAIRIE ISLAND NUCLEAR GENERATING PLANT - UNIT II i
September 6 to September 9, 1981-STEAM GENERATOR TUBE - EDDY CURRENT EXAMINATION l
.E INSPECTION PERIOD-3 i :
i l~
Report Dece:
NORTHERN STATES POWER COMPANY Commercial Services l
- MINNFAPOLIS. MINNESOTA I-
-October 29,'1981 Date: December 21,.1981
[".
-. = -
- - - -