ML20033A930

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 810914-18
ML20033A930
Person / Time
Issue date: 11/16/1981
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20033A928 List:
References
REF-QA-99900754 NUDOCS 8111300175
Download: ML20033A930 (1)


Text

.._

=

APPENDIX _A

][

OF VIOLATION Acimet Manufacturing Docket No. 99900754/81-01 As a result of the inspection conducted on September 14-18, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980),

the following violations were identified:

A.

Paragraph 21.6 of 10 CFR Part 21 states in part, "Each individual partnership, corporation or other entity subject to the regulations in this part, shall post current copies of the following documents in a conspicuous pcsition on any premises within the United States where the activities subject to this part are conducted:

(1) the regulations in this part, (2) Section 206 of the Energy Reorganiza-tion Act of 1974, and (3) procedures adopted pursuant to the regulations in this part.

}

"If posting of the regulations in this part or the procedures adopted pursuant to the regulations in this part is not practicab'e

... in addition to posting Section 206, post a notice which describes the regulations / procedures, including the name of the i

j individual to whom reports may be made, and states where they may be examined."

l Contrary to the above, posting of Section 206 of the Energy Reorgani-zation Act of 1974, or an appropriate notice had not been accomplished.

This is a Severity Level VI Violation (Supplement II).

B.

Paragraph 21.21(a) of 10 CFR Part 21 states in part, "Each individual, corporation, partnerthip or other entity subject to the regulations l

in this part shall adopt appropriate procedures to:

(1) Provide for:

(i) Evaluating deviations or (ii) Informing the licensee or purchaser of the deviation in order that the licensee or purchaser may cause the deviation to be evaluated... and (2) Assure that a director or responsible offic.r is informed if the... basic component supplied

... (i) Fails to comply... relating to a substritial safety hazard, or (ii) Contains a defect."

i l

Contrary to the above, procedures had not been adopted to provide for:

(1) evaluating deviations or informing the licensee or purchaser; and (2) assuring that a director or responsible officer was informed if the supplied basic component (a) failed to comply, or (b) contained a defect.

This is a Severity Level VI Violation (Supplement II).

4 8111300175 811116 PDR GA999 EMV** ***

l 99900754 PDR

-