Text
..
November 5, 1981 Rev.' 3
-YANKEE NUCLEAR POWER STATION IMPLEMENTING PROCEDURES TO THE EMERGENCY PLAN TABLE OF CONTENTS TABLE OF CONTENTS Rev. 0
+
CONTACT LIST Rev. '1 IMPLEMENTING PROCEDURES Classification of Emergencies OP-3300 Rev. 0 Unusual Event OP-3301 B'
. 0 Alert
_ OP-3302 Rev. 0 Site Area Emergency OP-3303 Rev.0
' General Emergency OP-3304 Rev. 0 Evaluation of Radiological Data OP-3310 Rev. 0 Emergency Off. Site Radiation Monitoring-OP-3311 Rev. 0:
'(
Emergency Radiation Exposure Control OP-3330 Rev. 0 Emergency Medical Procedure OP-3305 Rev. O Security Force Actions Under Emergency Conditions
' OP-3344 Rev.O Release of Public Informaticn Under Emer-gency Conditions OP-3343 Rev. 0 SUPPLEMENTAL PROCEDURES Emergency Plan Training OP-3340 Rev. 0 Emergency Preparedness Exercises & Drills OP-3341 Rev. 0 l Emergency Equipment Readiness Check OP-3325 Rev. 1 D
' 8111250095 8111~7
{DRADOCK05
,FDR.-
~.
D:pt. Supv.
juC. -
Proc. Na, OP-3325 i
- %P R2v. No.
1 (Major)
Plant Supt.
fee?g?
Review Date 11/83 Rad. Prot.Mgr. Af////
Mgr. of OPS RRVsp2)EA EMERGENCY EQUIPMENT READINESS CHECK SCOPE
~
To insure that radiological emergency equipment is periodically inven-tcried and maintained in an operable condition.
ENCIOSURES OP-3325 - Pgs. 1 Rev. 1 Attashment A - Pgs. 1 Rev. 1 Attachment B - Pgs. 1 Rev. 1 Attachment C - Pg. 1 - Rev. 1 Attachment D - Pg. 1 - Rev. 1 DISCUSSION The emergency equipment maintained in the Control Room, Technical Support Center, Operational Support Center, Emergency Van and the Emergency Operations Facility are listed on Attachment A, which is a complete inventory, catagoriized by kit function, location or both.
Each kit contains the necessary emergency equipment to support specific actions.
Certain items of the equipment require frequent checks to insure opers-bility, while otherido not.
Attachment B is a monthly check list of emergency equipment which requires specific checks at this frequency.
Attachment C is a check list of emergency equipment which requires specific checks once per calendar quarter. Attachment D is a blank form for discrepancies or observations noted and corrective measures taken.
Each kit is sealed with an easily broken-off closure that provides a method of verifying that the kit has or has not been opened since the last inventory. Provided that the seal remains unbroken any of those items requiring frequent checks need only be inventoried and checked monthly (e.g., portable survey meters, portable radios, flashlights).
Other equipment items (e.g., protective clothing, expendable supplies) need only be routinely inventoried annually.
All equipment in any kit, which.is found to have its seal broken, or one which has just been used, will be checkeo and inventoried.
The calibration cycles of emergency instruments are extended beyond the normal calibration cycles required by applicable calibration procedures.
The change to annual calibration cycle reflects the fact that these in-struments are not in regular use, but in storage, ready for use.
Along with requirements for annual calibration and quarterly battery condition inspection, the instruments will be battery and source checked monthly and after use.
.. OP-3325 Rev. 1-Record dats_in appropriate spaces. Perform check of test mode (switch on rear of units) with AC power cord plugged-in.
Check instruments for calibration due dates and re-cord in Section 2.2.2.. Check alarm feature of RM-14's and record.
2.2.3 Insert spare charcoal filter and a filter paper in the sampling head of the air samplers. Attach each battery powered air sampler to the van's battery and check the flow rate.. Flow rates should be approximately 30 liters per minute.
Perform this evaluation for all air samplers using the same charcoal cartridge and use different particulate filter paper if deemed necessary. Document flow rates obtained in Section 2.2.3.
2.2.4 Check dosimetry in each kit and document calibration due dates and record for each kit in Section 2.2.4.
2.2.5 Check dosimeter chargers in EOF kit by inserting a pen into the charger-dosimeter contact and verify its operability.
when the light is seen.
If this fails, replace battery and recheck. Document in space for EOF kits, Section 2.2.5.
2.2.6 Contact Gatehouse with portable radios and request a radio check. Document their operability status in Section 2.2.6.
2.2.7 Check EOF and off-site monitoring team kits for proper procedures and record revision number and date of re-vision in Section 2.2.7 of Attachment "B".
2.2.8 Check operability status of Eberline SAM-II in Section 2.2.8 of Attachment "B".
2.2.9 Reseal kits and record this in Section 2.2.9.
2.3 Road Barrier Team Kits shall be checked by initially verifying that the seal is intact and subsequently checking the operation of flashlights and hazard flashers for operability and checking the dosimetry for calibration due dates.
2.3.1 The batteri.-s are to be inserted into the flashlights to check its o.eration and then removed.
If any of the batteries are found to be leaking, damaged or corroded, or if any doubt exists as to their condition, replace them. Document this in Section 2.3.1.
2.3.2 Check the hazard flashers by inserting the pin attached into the' hole, observe operation and repeat the pin insertion to terminate operation.
If flasher fails, replace battery, bulb or both as appropriate.and check the space indicating satis-factory performance.
1 N
- OP-3325 Rev. 1 2.9 Proceed to Operational Support ' Center and complete 2.9;of Attachment "B".
2.10 Proceed to Gatehouse and complete Section 2.10 of Attachment "B".
Obtain key to Furlon House and record its availability status.
2.11 Proceed to Security Trailer and complete Section 2.11 of Attach-ment "B".
Check Daily Activity Security Log for Nuclear Alert-Rcdio Check. Enter date of latest check and results in Section 2.11.
2.12.
Proceed to Furlon-Housa and complete Section 2.12 of Attach-ment "B".
2.12.1.
Check seals on extra supplies container and record condition 2.12.2 Check charcoal filter purge system. Open main valve on gas cylinder and record pressure on high pressure regulator.
Close valve and exhaust the gas.
2.12.3 Check operation of VT Civil Defense phone.
2.13 Return keys to Gatehouse.
2.14 Saleet a small source (E 1 pCi 60Co or E 10 pCi 137Cs) and take newly cleaned and annealed TLD rings (12) for preparation for North Adams Regional Hospital.
NOTE:
Take necessary precautions to minimize your exposure to the source as well as exposure received by the TLD's.
2.14.1 On arrival at NARH, obtain the key to the emergency locker fzom Nurses' Station in the Emergency Room. Determine the name of the person from whom you receive the key and enter their name in the appropriate space on Section 2.14.1 to Attachment "B".
2.14.2 Go to closet and check seal. Record condition of the seal in Section 2.14.2.
2.14.3.
Perform source and battery checks on the RM-14 (with the AC cord removed) and record. Reattach AC cord and evaluate test mode (switch in rear). Check calibration due date and alarm check, and enter this data in Section 2.14.3.
2.14.4.
Perform source check on survey instrument with window open and window closed. Record this data, and calibration due date in spaces provided. Enter data on source used, activity and isotope in Section 2.14.4.
2.14.5.
Replace the old ring TLD's with their replacements. Enter date in Section 2.14.5.
2'.14.6 Ensure that all instruments are turned off.
m
, OP-3325 Rev. 1 4.1' REQUIREMENTS
- This must be performed for a kit that has been found with-its
~
seal broken, when any doubt exists regarding -the kit's inventory.
or annually.
4.2 An inventory shall be conducted on each kit according'to the-criteria ' in 4.1.by opening the kit and checking the contents.
against Attachment "A".
4.3 Record discrepancies on Attachment "D".
- 4.4 Perform monthly checks as in Section 2.
5.
FINAL CONDITION The completed Attachment (s) are-delivered to the Health Physics Supe rvisor.
1 L
A 4
- m. 4r, k
g
ATTACHMENT A OP-3325 EMERGENCT EQUIPMENT INVENTORY Att. "A" EMERGENCY OPERATIONS FACILITY Rev. 1 EMERGENCY CORRDINATION CENTER KIT Page 1 ITEM QUANTITY Emergency Plan Books, Revision No.
2 Portable Survey Instrument 1
RM-14 with HP-210 Probe 1
Air Sampling Kit (consisting of):
1 - 12 VDC Sample Pump 20 - Glass Fiber Filters and Envelopes 10 - Charcoal Cartridges 2 - Pencils 1 - Tweezers 2-Way Radio 1
Copies of Forms and Procedures 1 set Clipboard 2
Paper (Pads) 2 High Range Dosimeters 10 Dosimeter Chargers 2
Emergency Light (installed in Furlon House) 1 SAM-II 1-Teletype 1
Purge System 1
TLD Dosimeters 100 Computer Terminal (in Furlon House) 1 ROAD BARRIER TEAM KITS (4 Kits)
ITEMS IN EACH KIT QDANTITY Hazard Flasher & Battery 1
Flashlight & Battery 1
Sign & Rope 1
Cotton Gloves 4 pair Rubber Gloves 2 pair Rubber Shoe Covers 2 pair Plastic Shoe Covers 2 pair Paper Coveralls 2 pair Head Cover - Cloth 2
Head Cover - Paper 2
High Range Dosimeter 2
Respirator -Full Face 2
TLD Dosimeters 2
RE-ENTRY TEAM KITS (4 Kits)
ITEMS IN EACH KIT QUANTITY Heavy Plastic Suit 1
Cotton Gloves 2 pait Rubber Gloves 1 pair Rubber Shoe Covers 1 pair Plastic Show Covers 1 pair Paper Coveralls I pair Cloth Head Cover 1
Paper Head Cover 1
Respirator 1
TLD Dosimeters 1
.j.
- 0P-3325.
'Att. "A" -
i Rev 1 i-HOSPITAL KIT-
~
(See Peter Bent Brigham -
" Procedures for ' Radioactively -
Contaminated Patients")
- Area Radiation Monitor; 1
Continuous Airborne Radiation Monitor 1
High Range Dosimeters 25
' Thyroid Blocking Agent Kit 25 Respirators 25 ON-SITE OPERATIONS SUPPORT CENTER High-Range Dosimeters :
10 Protective' Clothing Kits (same'as-Control Room itemized)
-10 Thyroid Blocking Agent Kit 10 Survey Meter 1-BOILER FEED PUMP ROOM
~
Survey Instrument 1,
l Thyroid Blocking Agent Kit 100 High Range Dosimeters 25
' NOTE:
A SAM.II Dual Channel Analyzer is located at the Health Physics Control Point.
s I
I i
I t
i s
va J
J w
I a -
r g
-r-,
e-t
-e+
e-3 pg-p.
+
-.e y
ar p_---
y
+
v-
ATTACFMENT "B"-
OP-3325 MONTHLY EMERGENCY EQUIPMENT READINESS CHECK Att. "B" Rev. 1 Page 1 The emergency equipment contained in these checklists will be checked for calibration due dates, operability or document check as applicable.
Out of date equipment and documents and inoperable equipment will be replaced. The kits will be kept sealed. Those items not specifically requiring calibration, document or operability check need not be inven-toried if the seal is intact.
If the seal is broken, a complete inventory of the equipment and supplies must be taken.
A.
EMERGENCY VAN, EMERGENCY COORDINATION CENTER and eFF-SITE MONITORING KITS REFERENCES 2.1 Emergency Van Vehicle Check List performed (Maintenance)
~ ~ ~ "
2.2.1 Kit Seals:
BLACK WHITE RED PURPLE 2.2.2 Survey Meter BLACK #
WHITE #
RED #
PURPLE #
Battery Check Source Check Cal Due Date RM-14:
Cal. Due Date Battery Check Source Check Test Mode Check Alarm Check OP-3311, Rev. No.
REFERENCE Kit:
BLACK WHITE RED PURPLE 2.2.3
-DC Air Samplers Flow Rate:
2.2.4
~ Dosimetry Cal. Due Date:
2.2.5 Dosimeter Chargers (SAT /UNSAT)
N/A N/A' N/A 2.2.6 Radio Check 2.2.7 Document Check (Rev.#/Date) 2.2.8 SAM-II Check N/A N/A N/A 2.2.9 Kits Resealed 2.3 ROAD BARRIER TEAM KITS: KIT: #1
- 2
- 3
- 4 2.3 Sealed 2.3.1 Flashlight 2.3.2 Flasher 2.3.3 Dosimeter Cal.Due 2.3.4 Resealed
' OP-3325' Att. "B" Rev. 1 REFERENCE 2.9.1 Calibration Due Date of Dosimeters 2.9.2 Survey Meter No.
Cal. Due'Date Battery Check Source Check 2.10 Furlon House hey availability (Gatehouse) (Yes/No)-
2.11 Daily Activity Security Log: Nuclear Alert Radio Check Security Trailer - Date:
Results:
2.12 Furlon House 2.12.1 Condition of seal on extra supply locker 2.12.2 Check charcoal filter purge system psi 2.12.3 Check State of Vermont telephone system located in the Furlon Hotse by dialing 32.
VT Civil Defense will answer if system is operable. If no answer at Civil Defense, call VT' Civil Defense (802) 828-2163 and report system non-operable.
Initials:
2.13 Keys returned to Gatehouse 2.14 North Adams. Regional Hospital 2.14.1 Name of key issuer:
2.14.2 Condition of Seal 2.14.3 RM-14:
Cal. Due Date Source Check.
Battery Check Alarm Check Test Mode Check 2.14.4 Survey Meter Source Check Open Closed Source:
Act.
Iso.
2.14.5 Replace TLD Rings (date) 2.14.7 Cabinet Resealed (initials) 2.15.1 Check communications with the National Weather Service as follows:
Meteorological observations and forecasts are available on a 24-hour basis from Albany NES Forecasting Station at (518) 472-6586 by asking for the'Public Forecaster.
Date:
Initials:
OP-3325
,Att. "C" (Rev. 1.
+-.
Page 1-ATTACHMENT C'
~
QUARTERLY EMERGENCY EQUIPMENT READIhTSS CHECK y
.3.2 Whole Body TLDs' changed.
Initials:
' 3.2.1-All batteries' inspected for leakage, damage or. corrosion:
Results:
None found damaged
(. initials)
Exceptions:
Kit' Instrument - Observation.- Corrective Action' e-v.
- ~^*-~
.CHARC0AL FILTER PURGE SYSTEM CHECK 3.3.3 Flow Rate:
1/ min., hp gauge psi, 1 p. gauge
-psi' (Control Room) 3.4 Flow Rate 1/ min., hp gauge psi, 1 p. guage psif.
i.
4 I
r 6 b
-e o;-.
~
OP-3325
.Att. "D"
~
Rev. 1
.Page 1
~
. ATTACHMENT "D" t
.-ACTION OBSERVATION /.-
CORRECTIVE MEASURI-
[
DISCREPANCIES NOTED IMMEDIATE
.NEXT MONTH RECOMMENDAT:
I.
j I
l-
.i
\\
Health Physics Representative-Reviewed by:
Health ?hysics Supervision Action Taken on Discrepancies:
Health Physics Supervision b