ML20032D844

From kanterella
Jump to navigation Jump to search
Summary of Meeting W/Util & Sargent & Lundy in Bethesda,Md Re Staff Info Needs in Preparation for Environ Qualification Audit
ML20032D844
Person / Time
Site: Zimmer
Issue date: 11/03/1981
From: Peltier I
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8111180109
Download: ML20032D844 (9)


Text

.

.z e

%l NOV 3 1981

~

Dockat No.: 50-358

-.,..~,

APPLICANT: Cincinnati Gas & Elec,trjc, Company,,,,,,.,,

FACILITY:

Zimmer Nuclear Power,.Statjpn

SUBJECT:

ENVIRONMEllTAL QUALIFICATION WORKI!i,GEETIN_G,,,,,,,

u

Background

The NRC staff is in the process of reviewing.the Cincinnati Gas & Electric Company's Equipment Environmental. Qualification Program.. The meeting was called to discuss the staff'sjinformation. needs in preparation for the qualification audit. The atte'idance list and. presentation material are attached.

Summary, the_ status of the Equipment The applicant made a brief presentation,on, key,,, sche.dule, pilestones.

Qualification Program and outlined seyeral, e

The staff commented on the program components. and_ suggested that as time.

goes on, further discussion on some of them may,be helpful to expedite the applicant's submittals.

The applicant plans to justify interim opuation.by January 1982 and both parties agreed that April or May 1982 is.an appropriate target for an,SSER _.

on the equipment.

b I. A. Peltier, Project Manager.

.q1 Licensing Branch No. 1 Division of Licensing

Enclosures:

As stated cc w/encls.: See next page

_o,

,14 96.:.kBD.,,S,,,,

..gt,y.g.y.!.9.9.e

..e;ggg;pg;;; gag....................

,,D,(

f,,,,,,,,

omce >

g.g.-

m.,

nac ronu sta tio. son nacu o24o OFFICIAL RECORD COPY uso m ast-s m oo

Ar. Earl A. Borgmann

~

Senior Vice President Cincinnati Gas & Electric Company Post Office Box 960 Cincinnati, Ohio 45201 cc: Troy B. Conner, Jr., Esq.

Mrs. Mary Reder Conner, Moore & Corber Box 270, Rt. 2 1747 Pennsylvania Avenue, N.W.

California, Kentucky 41007 Washington, D. C.

20006 Andrew B. Dennison, Esq.

Mr. William J. Moran 200 Main Street General Counsel Batavia, Ohio 45103 Cincinnati Gas & Electric Company Post Office Box 960 George E. Pattison, Esq.

Cincinnati, Ohio 45201 Clermont County Proscuting Attorney 462 Main Street Mr. Samuel H. Porter Batavia, Ohio 45103 Porter, Wright, Morris & Arthur 37 West Broad Street Resident Inspector /Zimmer Columbus, Ohio 43215 RFD 1, Post Office Box 2021 U. S. Route 52 Mr. James D. Flynn, Manager Moscow, Ohio 45153 Licensing Environmental Affairs Cincinnati Gas & Electric Company Mr. Joha Youkilis Post Office Box 960 Office of the Honorable William Gradison Cincinnati, Ohio 45201 United States House of Representatives Washington, D. C.

20515 David Martin, Esq.

Office of the Attorney General Timothy S. Hogan, Jr., Chairman 209 St. Clair Street Board of Commissioners First Floor 50 Market Street, Clermont County Frankfort, Kentucky 40601 Batavia, Ohio 45103 James H. Feldman,Jr., Esq.

Lawrence R. Fisse, Esq.

216 East 9th Street Assistant Prosecuting Attorney Cincinnati, Ohio 45220 462 Main Street Batavia, Ohio 45103 W. Peter Heile, Esq.

Assistant City Solicitor Room 214, City Hall Cincinnati, Ohio 45220 John D. Woliver, Esq.

Legal Aid Security Post Office Box #47 550 Kilgore Street Batavia, Ohio 45103

MEETING WITH CG&E AND STAFF Environmental Qualification Program Attendance List NRC Staff CG&E Staff I. A. Peltier H. C. Brinkmann H. Walker G. A. Minges N. B. Le M. M. Slosson Sargent & Lundy J. E. Kennedy J. M. Rich A. L. Kapil R. J. Haninersley l

L.

e 9

8 A

INTRODUCTION UPDATE CURRENT STATUS ADVISE OF RHURE QUALIFICATION PLMS ESTABLISH GROLND RULES T0 f%INTAIN JULY 1982 FUEL LOAD

CURRENTSTATUS INITIAL SUBMITTAL JANijARY 1981

. EQUIPENT LIST

, ENVIR0ffENTAL PARANTER

. EVALUATION SHEETS SUPPLE E NT # 1 AUCE T 1981

. IDENTIFIED

- QUALIFIED

- REPLACE

- RE-QUALIFY

. RESPONDED.NRC QUESTION

- SYSTEMS LIST

- ETHOD OF REVIEW

- DISPL'AY INSTRUMENT

- TMI EQUIPE NT

- COLD SHLITDOWN EQUIPKNT

- SERVICE CONDITIONS ETHOD0llEY REANALYZE-EfNIROWENTAL PARATTERS DEVELOPING DETAILED ACTION PLANS REVIEW EERGENCY PROCEDURES FOR DISPLAY INSTRLFENTS

~

c.;

FUTUREPLANS SUPPLf?ENT # 2 ~ c DECENER 1981 EFIED APPROACH DESCRIPTION PARNETER RE-ANALYSIS IPPACT ON QUALIFIED EQUIPWhT DETAILED ACTION PLANS

,REPLACEENTS

-,RE-QUALIFICATI0N' SUPPLHENT # 3 - JANUARY 1982 JUSTIFY INTERIM OPERATION-SUPPIRENT # 4 - POST-0.L.

RESIJLTS OF RE-0UALIFICATION

N R C-S U B M I T T'A L R E Q U I R E M E N T S SUPPLEMENT-REQUIREMENTS

-SUBMIITAL-1 2

3-I4 PROGRAM DESCRIPTION X --

X X-SAFET/-RELATED LIST SYSTEMS IDENTIFIED X.

X

-X X

X-

- IE LIST FOR SYSTEMS X

X

)(

X

- DISPLAY INSTRLFEiTATION

-X' X

X

- TMI EQUIPMENT X

X X

- COLD SHUIDOWN EQUIPMENT X

X~

X~

SERVICE CONDITIOll METHODOLOGY

- LOCA X -.

X X

i

- HELB X-X

-X~

RADIATION-X

.X X

- SUBMERGENCE

-X

- CHEMICAL / DEMINERALIZED WATER SPRAYS X

AGING X

X MARGIN X

X l

COMPONENT EVALUATION WORK SHEET

- DESCRIPTIC'l 0F DEFICIENCIES X

X

-ACTION PLANS FOR BEFICIENCIES X

X

- JUSTIFICATION FOR INTERIM OPERATION X

i

ee '

e 6

,,e GROUNDRULES JULY 1982 FUEL L.0 A D FIELD AUDIT JANUARY 1982 FUEL LOADING JULY 1982

- ACCEPTABLE INTERIM JUSTIFICATION

- EXPEDITED RE-QUALIFICATION

m e

l q

MEETING

SUMMARY

DISTRIBUTION N

S it' DobketFile G. Lear

/b b

g

.d b[g'h S]

i

.NRC PDR NOV 3 19 3 ;

W. Johnston

,g Local PDR S. Pawlicki TIC /NSIC/ Tera V. Benaroya

,,s.

N. Hughes Z. Rosztoczy e.

LB#1 Reading W. Haass H. Denton D. Muller

  • ' FA E. Case R. Ballard D. Eisenhut W. Regan R. Purple R. Mattson B. J. Youngblood P. Check A. Schwencer F. Congel F. Miraglia
0. Parr J. Miller F. Rosa G. Lainas W. Butler R. Vollmer W. Kreger J. P. Knight R. Houston R. Bosnak F. Schauer L. Rubenstein R. E. Jackson T. Speis Project Manager I. A. Pel tier M. Srinivasan Attorney, OELD J. Stolz M. Rushbrook S. Hanauer 0IE (3)

W. Gammill ACRS (16)

T. Murley R. Tedesco F. Schroeder D. Skovholt M. Ernst NRC

Participants:

R. Baer C. Berlinger I. A. Peltier K. Kniel H. Walker G. Knighton N. B. Le A. Tnadani M. M. Slosson

'D. Tondi J. E. Kennedy J, Kramer D, Vassallo P. Collins l

D. Ziemann 1

bcc:

Applicant & Service List l

l

.