ML20032B237

From kanterella
Jump to navigation Jump to search
Forwards Util to Jf Stolz Re Mods to Completion Dates for Certain NUREG-0737 Items.Ltr Does Not Alter Licensee Commitment to Provide Backup Display Capability for in-core Thermocouples.Related Correspondence
ML20032B237
Person / Time
Site: Crane 
Issue date: 10/30/1981
From: Baxter T
SHAW, PITTMAN, POTTS & TROWBRIDGE
To: Jordan W, Little L, Smith I
Atomic Safety and Licensing Board Panel
Shared Package
ML20032B238 List:
References
RTR-NUREG-0737, RTR-NUREG-737 NUDOCS 8111050331
Download: ML20032B237 (4)


Text

^

~

Inua cc:mremen 1

SHAw, PITTMAN, PoTTs & TROWBRIDGE 1000 M ST R E ET, N. W.

WASHINGTON. D. C. 20036 sawSAv D POTTS M ARA AVGENSL5CR DAVID M RUBENSTEIN MO*ARD M SM AF F E RM AN STE UART L PiTT A AN ERNEST L BLAnt. JP 12O2i 822-iOOO M ATI AS F. YRaviESO-Di A2 DEBORAMe BAUtER RTE PHEN O P TS THC AE A BA R

J MN M ON LL R SET H M AS N GERs.LD CM ARNorr JAMES M BURGER Jay A C PSTIE N Se*E sL A E McCAFFERTV SHELDON J *EISE T E L E COP *E f' RAND L ALLEN.

DELI $$A A R p DG W AV PMeL L.IP D ROST,Wace D Tse OTMY MANLON JOMN A McC U L L OU<

TWOTMV e MGRiDE mENNETM J M AUTM AN 12O26 022-8099 & 822.n99 GEO SGC M ROGERS. JR J PATRICK MICP E T ELISABETH M PE NDLETON DAVID LAWRE NCE MILLER FFED A L ITT L E GEORGr P MsCMAEL%

JOMN B RMf NE LANDE R JAMES 1 eOMAS LENS

  • PAUL A RAPLAN ANNE M ERAUSmOPF MARRYM G LA SSpl E GE L FRE DE RICM L M L EIN WUCE W C M U RC M cL L STEVEN s M E LTZE R TELEX RANDAL e pCLL GORDON R es ANOF$av LESLtE A N 'C MO L SO N JR FEAND AULiCR THOMASM Mc C OR M a C M SALLY C ANDREWS 89-2693 ISM AWLAW WSMI SUSAN D FALRSON JE.FFREY S Ga ANCOLA MARTIN O mRALL JOMN ENGEL RsC M ARD J 8' E NDALL ST E PHE N 9 HUTT L E R C ABLE "SM AWLAW-WILLIAM P BARR MANNAME M LIE BE RM AN JAY E StL S E RG WINTMROP N BROWN SUSAN M FREUND SANDRA E FOLSOM OARI AR A M ROSSOTTe JAMES 8 MAMLIN JOMN L CARR JR M ARCI A R NeRENSTEIN E DRAS ER C M ARD E GAL E N WRITER S DsRECT DsAL NUMBER RT M GOR N

DWARD D TOU G til

. BARS AR A JO~~IE S GOTTuE.N W E.ND.E LIN A. WMIT E '

MODGE R st E NLY WE BS.TE R 822-1090 ROBERTB RO B B IN S N ATM.N.E L P REED.JR STEvCN M iUCAS

-....m....

October 30, 1981 Ivan W.

Smith, Esquire Dr. Walter H.

Jordan Chairman Atomic Safety and Licensing Atomic Safety and Licensing Board Board Panel U.S ear Regulatory Commission 881 West Outer Drive J c6Ih t%f p.C.

20555 Oak Ridge, Tennessee 37830 3

Dr. Linda W. Little 77

- g 5000 Hermitage Drive Atomic Safety and Licensing 2

Board Panel D

[f Raleigh, North Carolina 27612 00f.KETED

/gI% g^

v U%RC

%x In the Matter of Metropolitan Edison Compiny

'ree Mile Island Nuclear Station, Unit No. 41 NOV -2 PS:04 Docket No. 50-289 (Restart) 0FFICE OF SECRETAR1 Adr h 'strative Law Judge Smith and Administrative JNhhhC Joroan and Little:

Please find enclosed, for your information, a copy of a letter from Metropolitan Edison Company to the NRC Staff, dated October 27, 1981 (LIL 312), on modifications to the completion dates for certain NUREG-0737 items.

You will note that one of the schedule modifications discussed is for NUREG-0737 item II.F.2, Backup Incore Thermo-couples.

I remind the Board that, independent of NUREG-0737, Licensee committed, in response to the NRC Staff's supple-mental control room design review report (Staff Exhibit 15:

Supplement No. 1 to NUREG-0752) to provide the back-up display capability for in-core thermocouples recommended in that S

8111050331 811030

/ [

PDR ADOCK 05000289 0

PDR

p SHAW, PITTMAN, POTTS & TROWBRIDGE Ivan W.

Smith, Esquire Dr. Walter H. Jordan Dr. Linda W. Little October 30, 1981 Page Two report' prior to exceeding 5% power.

(Licensee PF 318).

The enclosed letter-does not alter that commitment.

Sincerely, r

Thomas A. Baxter Counsel for Licensee TAB:jah Enclosure cc:

Service List attached e

e

s' 4

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

l SERVICE LIST

~

Ivan W. Smith, Esquire John A. Ievin, Esquirr Ch irman Assistant Counsel Atcmic Safety and Licensing Pennsylvania Public Utility Comniesion Board P.O. Box 3265 U.S. Nuclear Regulatory Carmission Harrisbu2g, Pennsylvania 17120 Washn W, D.C.

20555

~

Karin W. Carter, Esquire Dr. Walter H. Jordan Robert Adler, Esquire Atcmic Safety and Licensing Assistant Attorney General Board Panel 505 Executive House 1

881 West Outer Drim P.O. Box 2357 Oak Ridge, Tennessee 37830 Harrisburg, Pennsylvania 17120 Dr. Linda W. Little John E. Minnich Atcmic Safety and Licensing Chairman, Dauphin 03unty Board Board Panel of Conmissioners 5000 Hermitage Drive Dauphin County Courthouse Raleigh, North Carolina 27612 Front and Market Streets Harrisburg, Pennsylvania 17101 James R. Tourtellotte, Esquire Office of the Executive Icgal Director, Walter W. Cohen, Esquire U.S. Nuclear Regulatory Comnission Consumer Advocate Washington, D.C.

20555 Office of Consumer Advocate 1425 Strawberry Square Docketing and Service Section Harrisburg, Pennsylvania 17127 Office of the Secretary U.S. Nuclear Regulatory Comnission Washington, D.C.

20555 m- - - -

w,

,._y-%-,.,.

,c-

,.,w.- - -.,,

--.,---,,-,-y._,-.,,,4, m

4--.

Jordan D. Cunningham, Esquire Robert Q. Pollard 2320 North Second Street 609 Montpelier Street Harrisburg, Pennsylvania 17110 Baltimore, Maryland 21218 Ms. Iouise Bradford Chauncey Kopford

'IMI ALERP Judith H. Johnsrud Harrisburg, Pennsylvania 17102 Environmental Coalition.on Nuclear Power 1011 Green Street 433 Orlando Avenue State College, Pennsylvania 16801 Ellyn R. Weiss, Esquire Harmon & Weiss Marvin I. Iewis 1725 Eye Street, N.W., Suite 506 6504 Bradford Terrace Washington, D.C.

20006 Philadelphia, Pennsylvania 19149 Steven C. Sholly Marjorie M. Aamodt Union of Concerned Scie'.tists R. D. 5 1725 Eye Street, N.W., Suite 601 Coatesville, Pennsylvania 19320 Washington, D.C.

20006

'Ihomas J. Germine, Esquire -

Gail B. Phelps Deputy Attorney General ANQW Division'of Iaw Room 316 245 West Philadelphia Street 1100 Raymond Boulevard Ycrk, Pennsylvania 17404 Newark, New Jersey 07192 William S. Jordan, III, Esquire Hanton i Weiss.

1725 Ei3 Street, N.W., Suite 506 Washington, D.C.

20006 Professcr Gary L. Milhollin 1815 Jefferson Street Madison, Wisconsin 53711 1

-