g j

OCT 7 1981 Un iet flos.

and 50-486 MEMOPJUlDU!! FOR:

B. J. Youngblood, Chief. Licensing Branch No.1. DL i

FRO l1:

G. E. Edison, Project Manager, Licensing Branch flo. 1. DL

SUBJECT:

FORTHC0!!ING MEETING WITH UllIO!! ELECTRIC C0tiPAllY C0tlCERNING

!!ATTERS RELATED TO CASELOAD FORECAST FOR THE CALLAWAY PLA!!T, UNITS 1 & 2

/

DATE AND TIME:

Tuesday, Wednesday and Thursday, October 27, 28 and 29, 1931 8:30 am LOCATI0il:

Hokane Lions Club

!!okana, liissouri 65059 PURPOSE:

To discuss matters related to caseload forecast for the Callaway Plant, Units 1 a 2 PARTICIPANTS:

NRC Staff W. Lovelace, G. E. Edison, et al Union Electric Comoany, A. Passwater et al.

Origirmi signed by Gordon E. Edison G. E. Edison, Project Manager Licensing Branch No. 1 Division of Licensing Attachraent:

As stated cc:

See next page Note: Members of the public wishing to attend should contact G. E. Edison at 301-492-7219 by October 20, 1981 so that arragements can be made for their attendance.

nd $/ $)

/

BMu'h'o***'d"

.DWL omcn >

..D.1,.;.L.B.{.1, 6001 811007

.................. % R DOCK 05000483.. ' '. _ *

  • _
  • _ * *. " _ _ ' " _ " _ ' ".

............../ y t Edison ngbl o

$URNAME>

pon 10.Cf../8,1...

1g( /,8,1...,,,,.A om>

nac ronu m pma nncu om OFFICIAL RECORD COPY usam mi-muo

i Mr. D. F. Schnell Vice President - Nuclear Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 cc: Mr. Nichols A. Petrick Executive Director - SNUPPS 5 Choke Cherry Road Rockville, Maryland 20850 Gerald Charnoff, Erq.

Shaw, Pitman, Potts &

Trowbridge 1800 M Street, N. W.

Washington, D. C.

20036 Mr. J. E. Birk Assistant to the General Counsel Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Dr. Vern Starks Route 1, Box 863 Ketchikan, Alaska 99901 Ms. Treva Hearn, Assistant General Counsel Missouri Public Service Commission Post Office Box 360 Jefferson City, Missouri 65102 Mr. William Hansen U. S. Regulatory Commission Resident Inspectors Office RR#1 Steedman, Missouri 65077 Mr. Donald W. Capone, Manager Nuclear Er.gineering Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 J

y

f 1

CASELOAD FORECAST PANEL SITE VISIT MEETING AGENDA e

II Overview of project construction schedule including progress fv and major milestones Completed, current problems and any anticipated problem areas that may impact the current projected i

e fuel load date.

- (

2.

Detailed review and current status of design and engineering effort (by major discipline) including any potential problems

/

that may arise from'decessary rework.

~

3.

Detaile,d review and current status of procurement activities includirg valves, pipe, instruments, cable, major components, etc.

q

4. _ Actual and proposed craft work force (by major craft), craft availability, productivity, potential labor negotiations and problemc.

i

~

5.

Detailed review and current status of all large and small bore pipe hangers, restraints, snubbers, etc., including design, rework, procurement, fabrication, delivery and installation.

6.

Detailed review of project schedule identifying critical path items, near critical items, amount of float for various activities, the current critical path to fuel loading, metho_ds of implementation of corrective action for any activities with negative float, and provisions for contingencies.

The estimated project percent complete as of September 30 -1981.

7.

Detailed review and current status of bulk quantities including current estimated quantities, quantities installed to date, quantities scheduled to date, current percent complete for each, actual versus forecast installation rates, and basis for figures.

(a) Concrete (CY)

~

(b) Process Pipe (LF)

Larg'e Bore Pipe (21/2" and larger)

- - Small Bore Pipe (2" and smaller)

.i (c) Ya'rd Pipe (LF)

(d).LargeBorePipeHangers, Restraints, Snubbers (ea) 7

, _ j, 4-J f

4 4 -

e seemus>=

h -e-'d-

=*-*

ea w-w--_-a,-,

p a

e

==- < *

~

he

(e) Small Bore Pipe Hangers, Restraints (ea)

(f) Cable Tray (LF)

(g) Total Conduit (LF)

(h) Total Exposed Metal Conduit (LF)

(1) Cable,(LF)

Power Control Security

- !astrumentation Plant Lighting (j) Terminations (ea)

- Power Control e

- Security Inscrumentation Plant Lighting (k)

Electrical Circuits (ea)

Tower Control Security (1)

Instrumentation (ea) 8.

Detailed review and current status of preparation of preop and acceptance test procedures, integration of preoo and acceptance test activities with construction schedule, system turnover schedule, preop and acceptance tests schedule, current and proposed preop and acceptance tests program manpower.

(a) Total number of procedures required for fuel load.

(b) Number of oraft procedures not started.

(c) Number of draft procedures being written.

(d) Number of procedures approved.

(e) Nuniber of procedures in review.

(f) Total number of preop and acceptance tests required for fuel load.

(g) Number of preop and acceptance tests comp'eted.

(h) Number of preop and acceptance tests :urrently in progress.

,(i ) Number of systems turned over to start-up.

T 1_.%

i 3

1 9.

Detailed discussion of potential schedular influence due to changes attributed to NUREG-0737 and other recent licensing requirements.

i

10. Discussion of schedular impact, if any, regarding potential deficiencies reported in accordance with 10 CFR 50.55(e).

4 j

11.

Financial commitments to complete the plant.

12. Overview of current construction management organization and activities.
13. Site tour and observation of construction activities.

J J

O i

4 O

+

MEETING NCTICE DISTRIBUTION J. Stolz o Ket F' DR OCT 7.1%1 S. Hanauer P. Collins c.

Local PDP.

D. Vassallo d) 9)

TIC D. Ziemann g

i I

.h 9

NSIC T. Murl ey Q

F. Schroeder U

I TERA Branch File K. Kniel l*

OCT 141981m-Gi, E. Case D. Skovholt D. Eisenhut G. Knighton ommumme R. Purple M. Ernst b

(//

'f}/

T. Novak R. Baer e

S. Varga E. Adensam

/,,

(b T. I'ppolito A. Thadani R. A. Clark ACRS (16)

N. Hughes Attorney, "ILD R. Tedesco OIE (3)

J. Youngblood CSD '7)

A. Schwencer Project Manager _GEdison F. Miraglia Licensing Assistant M. Rushbrook J. R. Miller Receptionist G. Lainas D. Crutchfield J. LeDoux, I&E W. Russell J. Olshinki I&E Headouarters R. Vollmer I&E Region I R. Bosnak I&E Region II F. Schauer

!&E Region III R. F. Jackson I&E Region IV G. Lear I&E Region V W. Johnston S. Pawlicki NRC

Participants:

V. Benaroya Z. Rosztoczy W. Lovelace, G. E. Edison W. Haass D. Muller R. Ballard W. Regan V. Moore D. Ross P. Check bcc: Applicant & Service List

0. Parr F. Rosa W. Butler W. Kreger R. W. Houston F. Congel W. Gammill L. Rubenstein T. Speis M. Srinivasan B. Grimes S. Schwartz F. Pagano

~

.S.

Ramos J. Kramer

_ _ _ _ _ _ _ _ _ _ _