O O

~

Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 C R For Radioactive Materials Packages i

1 1.(s) i icate Number 1.(b) evision No.

1.(

a d

fication No.

1.( ) Pages No.,1.(

Total No. P. ages

2. PREAMBLE 2.(al ~This certificate is issued to satisfy Sections 173.333a,173.394,173.395, and 171.396 of the Department of Transportation Ha'zardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CF R 146-149), as amended.

2 (b) The packaging and c>ntents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or applicatiort-l 3.(a) ' Prepared by (Name and address):

3.(b)

Title and identification of report or application United Nuclear Corporation United Nuclear Corporation Application dat'ed

.67 Sandy Desert Road February 12, 1981.

Uncasville, Connecticut i

i 06382 71-5641 3.(c)

Docket No.

1 4.

CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable and the conditions specified in item 5 below.

1

5. Description of Packaging and Authorized Contents, Model Number, Fissile Class. Other Conditions, and

References:

(a)

Packaging 1

(1) Model No.: UNC-2500 (2)- Description Specific packagi ig is not required.

Safety of shioment is independent of packaging 5

-m A 6 '*

5.

(b)

Contents :

3 o

a, u.

m,;

y-

.. m

gn.

. gm

. S y

. +

M.c 1 9(1): Tipe~ and formiof material e. ~

A dp

'~ ~if, _ % # D.?

i M, i

=

Un,i,rradiated U-235 enriched fuel clusters and modules.

l 4

(2) Maximum quantity of material per package i

Not to exceed Type A quantities radioactive material with contents of a single shipping container limited to one (1) module or cluster demonstrated subcritical (water moderated and reflected) as evaluated and approved in NRC SNM license No. 368.

t (c)

Fissile Class III 8110230592 810807 PDR ADOCK 07105641 C

PDR

o O

r Page 2 - Certificate No. 5641 Revision No. 2 - Docket No. 71-5641 l

6.

Alternatively, a maximum of 700 grams U-235 or 40 grams U-235/ inch (not stacked) of the type and form of naterial specified in 5(h)(1) may compose a Fissile Class III shipment.

7.

The'name plate' to which the Model No. is affixed must be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintain its legibility.

, 13.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date: March 31, 1986.

REFERENCE United Nuclear Corporation application dated January 12, 1981.

l FOR THE U.S. NUCLEAR REGULATORY COMMISSION 9

+

w i

Charles E. MacDonald, Chief Transportation Certification Branch j

Division of. Fuel Cycle and Material Safety, NMSS '

Date:

i J

z c

e

~

,~ 5

~~

s

'5.

s m-A 1

4 ee 1

~

. - -