ML20031G124
| ML20031G124 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 10/19/1981 |
| From: | Bishop C NRC ATOMIC SAFETY & LICENSING APPEAL PANEL (ASLAP) |
| To: | |
| References | |
| ISSUANCES-SP, NUDOCS 8110210129 | |
| Download: ML20031G124 (1) | |
Text
UNITED STATES OF AMERICA WUCLEAR REGULATORJ COMMISSIO14 ATOMIC SAFETY AND LICENSING APPEAL BOARDCKETED USNRC Administrative Judges:
11 T 19 P.2:13 Alan S..Rosenthal, Chairman Dr. W.
Reed Johnson Stephen F.
Eilperin OFFICE OF SECRETARY 00CKETING & SERVICE BRANCH
)
In the Matter of j
SERVED 00T191981 FLORIDA POWER & LIGHT COMPANY
) Docket Nos. 50-250 SP
)
50 (Turkey Point Nuclear Generating)
/s Station, Units Nos. 3.and 4)
)
Gig' I2 T
MEMORANDUM M e,c.,,,OISOi ~
3 October 19, 1981 kb/,.
Counsel for the parties.are to be prepared to' discuss at oral argument the apparent discrepancy between the Final Environmental Statement and the affidavit of Alan J. Gould as to the amount of. low level radioactive waste to be generated by the Turkey Point steam generator repairs.
The FES, p.4-ll, gives an FPL estimate of 1100 cubic meters (38,846 cubic feet) per unit not including the steam generator assemblies, while the Gould affidavit, Table 1, specifies 22,335 cubic feet l
l excluding the steam generator lower assemblies.
Counsel I
l should also be prepared to discuss the underlying assumptions for Tables 2 and 3 of the Gould affidavit.
l FOR THE APPEAL BOARD l
C. CLm
&A D
Secr $ Bishop l[/
C.
J
\\
etary to the O
Appeal Board 8110210129 811019 PDR ADOCK 05000250 G
__